Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L for concealed point wiring for controlled by one switch with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with including one run of PVC insulated FRLSH copper conductor cable of 1.5 Sqmm with green insulation as earth wire and connected to earth dolly complete all as specified and directed.(a) One light point controlled by one, one way switch |
| 2 | -Ditto- all item as per Ser No 1.00 above but One fan/exhaust fan point controlled by one, one way switch |
| 3 | -Ditto- all item as per Ser No 1.00 above but One socket outlet 3 Pin, 6 Amp on independent board |
| 4 | -Ditto- all item as per Ser No 1.00 above but One socket outlet 3 Pin, 6 Amp on same board. |
| 5 | M&L for point wiring for controlled by one switch with PVC unsheathed single core multistranded copper conductor cable of size 4 Sqmm (nominal area) in and including PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling including one run of PVC insulated FRLSH copper conductor cable of 4 Sqmm with green insulation as earth dolly for 6 pin, 16 Amp socket outlet on Independent board. |
| 6 | S&F Modular switch 6 Amp 250 V AC one way one module complete all as specified and directed. |
| 7 | S&F Modular switch 20 Amp 250 V AC one way with indicator one module complete all as specified and directed. |
| 8 | S&F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 9 | S&F Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 10 | S&F modular Fan regulator step type, 120W - 2 module complete all as specified and directed. |
| 11 | M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) |
| 12 | Supply and fixing Surface and wall mounted LED tube light fittings of cap 20W , four feet Basic all purpose surface and wall mounted LED batten with polycarbonate housing including taking down with all as specified and directed. |
| 13 | Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 with brushless direct current motor (BLDC) |
| 14 | supply and fix exhaust fan steel body AC single phase 230/240 v of size 300 mm sweep with louver all as specified and directed by engineer-in-charge |
| 15 | Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral including taking down complete all as directed by Engineer-in-Charge. |
| 16 | (a) S & F MCB, 6 to 32 Amp, SP, 240 Volt. complete all as specified and directed. |
| 17 | (b) S&F MCB, 40 Amp, SPN, 240 Volt 10 KA, 'C' curve complete all as specified and directed. |
| 18 | Supply, Installation, Testing and Commissioning (SITC) of 1.5 kW capacity rooftop grid-connected solar power plant with offgrid inverter/PCU and Lithium Iron Phosphate (LiFePO4) battery backup system designed for 300 Watt connected load with minimum 12 hours continuous backup facility. The system shall comprise high efficiency MNRE approved-AlMM listed solar PV modules of minimum 20% efficiency with 25 years linear performance warranty (minimum 90% for 10 years and 80% for 25 years), mounted on hot dip galvanized (80 micron) MS mounting structure capable of withstanding 150 km/h wind load, with adjustable tilt as per site condition.The inverter shall be of minimum 1.5 kW capacity with MPPT technology, minimum 95% conversion efficiency, inbuilt protections (Over charge protection,Under charge protection , reverse polarity, overload, short-circuit, surge protection).Manre & BIS Approved.The Lithium-Ion battery bank shall consist of minimum 4 nos. of 12V 100Ah LiFePO4 batteries connected suitably in series/parallel combination to provide minimum 4.8 kWh usable storage capacity (considering 80% Depth of Discharge) sufficient to support 300W connected load for 12 continuous hours. The battery shall have integrated advanced Battery Management System (BMS) with protections against overcharge, over-discharge, short-circuit, thermal management, and cell balancing, ensuring minimum 4000 charge-discharge cycles at 80% DoD and minimum 5 years warranty.The system shall include all cabling works using IEC/ISI certified DC and AC cables, chemical earthing for both AC/DC sides, suitable Surge Protection Devices (SPD), MCBs/MCCBs as per IEC standards, required civil works for mounting structure and cabling, proper cable trays/conduits, and fire safety arrangements including installation of dry powder type fire extinguishers for lithium-ion safety.The contractor shall also provide appropriate safety signage, operational labels, emergency shutdown procedures, single line diagrams, operation & maintenance manuals, training to end-user staff and shall obtain necessary statutory approvals from MNRE, DISCOM, Electrical Inspector, and relevant authorities.The system shall achieve a guaranteed Performance Ratio (PR) of minimum 75% on annual basis and shall include remote monitoring facility with minimum 5 years data retention for generation, battery status, grid availability, and fault history. Comprehensive Operation & Maintenance (O&M) services shall be provided for a period of 5 years after commissioning, including periodic preventive maintenance, breakdown services, and performance monitoring support.The entire system shall be designed, supplied, installed, tested, and commissioned complete in all respects, conforming to latest MNRE, BIS, IEC, CEA, and local DISCOM regulations and as per directions of Engineer-In-Charge.Make:-UTL,Luminious,Statcon for INVERTERMake:-UTL,Waaree,Livguard,Exide For Lithium-Ion battery |
| 19 | 1. Taking down carefully aluminium point wiring on wooden battens/through conduit (light fan, socket or power) complete with fittings such as switches, wooden batten, ceiling roses, pendants, regulators, box type tube light fittings, removing the materials from site except fittings etc which shall be reused in the work and making good the disturbed surfaces of walls/ceiling/ floors etc complete all as specified and as directed by Engineer-in-Charge |
| 20 | 2. M&L for concealed point wiring for controlled by one switch with PVC insulated but unsheathed single core FRLS multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with including one run of PVC insulated FRLS copper conductor cable of 1.5 Sqmm with green insulation as earth wire and connected to earth dolly complete all as specified and directed.One light point controlled by one, one way switch |
| 21 | -Ditto- all item as per Ser No 18.00 above but One fan/exhaust fan point controlled by one, one way switch |
| 22 | -Ditto- all item as per Ser No 18.00 above but One socket outlet 3 Pin, 6 Amp on independent board |
| 23 | -Ditto- all item as per Ser No 18.00 above but One socket outlet 3 Pin, 6 Amp on same board. |
| 24 | -Ditto- all item as per Ser No 18.00 above but One bell point controlled by one bell push |
| 25 | -Ditto- all item as per Ser No 18.00 above but One light point controlled by one 2-way switch |
| 26 | M&L for point wiring for controlled by one switch with PVC unsheathed single core multistranded copper conductor cable of size 4 Sqmm (nominal area) in and including PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling including one run of PVC insulated FRLS copper conductor cable of 4 Sqmm with green insulation as earth dolly for 6 pin, 16 Amp socket outlet on Independent board. |
| 27 | S&F switch piano flush type single pole one way 5 Amp (ISI Marked) |
| 28 | S&F switch piano flush type single pole one way 15 Amp (ISI Marked) |
| 29 | Supply & fix in repair single pole and neutral enclosure 2 module in sheet steel with a two pin and earth plug and socket complete with including one single pole MCB 20 Amp 10 KA complete all as specified and directed. |
| 30 | S&F Bell push flush type single pole one way 5 Amp (ISI Marked) |
| 31 | S&F socket out let 2 in 1, 3 pin 5 Amp flush type (ISI Marked) |
| 32 | S&F socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked ) |
| 33 | S&F switch piano flush type single pole two way 5 Amp. |
| 34 | M&L for bell multi music type, AC 230 Volts, single pole (ISI Marked) |
| 35 | Supply and fix Electronic fan regulator 230 volts, step type,socket type ,hum free 120 watt ISI Marked,including taking down unserviceable. |
| 36 | M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) |
| 37 | Taking down of old existing unserviceable submain wiring of any rating. |
| 38 | M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLSH wire 6.00 Sq mm 1100 volts grade including and 06.00 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in PVC conduit incl cutting, chases in stone wall and match with the existing surface complete all as specified and directed.Note : Two run of 06.0 Sqmm cable and one run of 6.0 Sqmm cable as earth continuity conductor shall be measured & paid as one unit. |
| 39 | M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLSH wire 4.00 Sq mm 1100 volts grade including one 4 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in PVC casing caping / conduit incl. Note : Two run of 4.00 Sqmm cable and one run of 4 Sqmm cable as earth continuity conductor and 25 mm PVC conduit shall be measured & paid as one unit. |
| 40 | Supply and fixing Surface and wall mounted LED tube light fittings of cap 10W , Two feet Basic all purpose surface and wall mounted LED batten with polycarbonate housing including taking down with all as specified and directed. |
| 41 | Supply and fixing Surface and wall mounted LED tube light fittings of cap 20W , four feet Basic all purpose surface and wall mounted LED batten with polycarbonate housing including taking down with all as specified and directed. |
| 42 | Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral including taking down complete all as directed by Engineer-in-Charge. |
| 43 | S&F inlcuding taking down unserviceable MCB’s of any type. S & F MCB, 6 to 32 Amp, SP, 240 Volt. complete all as specified and directed. |
| 44 | -Ditto- all item as per Ser No 36.00 above but S&F MCB, 32 Amp, SPN, 240 Volt complete all as specified and directed. |
| 45 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.(ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order.(iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. |
| 46 | Supply, install, testing and commissioning including taking down of indoor LT panel size 800 mm x 600 mm x 150 mm enclosures cubical weather and vermin proof totally enclosed made out of 1.6 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ with front openable and PVC acrylic glass cover suitable size for checking of meter reading without opening door with locking arrangement incl inner shutters for mounting switch gear etc, suitable arrangement for fixing of electrical meter and SPN 40 to 63 Amp including pre wiring from Bus bar to Meter and Meter to MCB SPN (for pre wiring use 6.00 Sqmm Single core copper cable and suitable size of lugs for connecting from Busbar to meter and meter to MCB SPN)including bottom gland plate with sufficient numbers of circular cable entry holes, including prewired complete as per drawing with masonary work for fixing in wall duly powder coated with comprising of the following :-INCOMING :-(i) MCCB 125 Amps FP, 415 Volt 25 KA adjustable thermal & fixed magnetic setting Ics = 100% = 01 No (ii) Phase indicating lamp LED type with HRC fuse – 1 Set of three(iii) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos(iii) Aluminium bus bar 200 Amps capacity with bus bar supports, DMC/SMC insulators of CPRI approved of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos. OUT GOING (i) MCB 32 Amp,415 Volt,10 KA, Single pole and neutral -05 No(ii) Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH type display with transparent hinge including connection from SPN to meter with 6 Sqmm copper stranded conductor including earth wire complete all as specified and directed by Engr-in-Charge. - 04 Nos |
| 47 | Taking down carefully ceiling fan 230 volts single phase 50 Hz from the position after dismantling fan blades of any sweeps and carrying out complete servicing with and including winding ,cleaning, greasing, replacing flexible 3 core cable of size 1.5 Sqmm with copper conductor from ceiling rose to fan, replacing rubber reel, split pins, check nuts, PVC connector,Down rods ,Plastic conapy,Bearings, shafts etc..complete with and including painting with 2 coats of synthetic enamelled paint over a coat of red oxide anticorrosive primer after rubbing entire fan body and one coat of white colour and blades and fixing back the fan in position complete all as specified and directed. |
| 48 | Supply and fixing of ceiling metal electrical fan box , round or square shape all are specified and directed by engr in charge |
| 49 | Supply and fix exhaust fan, steel body Heavy duty ,AC single Phase. 230V of size 300mm sweep with, blades and frame and louvers including making holes in to the wall as per fan size and making good the disturbed surfaces complete all as specified and directed. |
| 50 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm sweep including making holes in to the wall/cutting the window or ventilator as per fan size and making good the disturbed surfaces complete all as specified and directed. |
| 51 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection , Suitable for 30 to 40 mm O.D Mountingn Pipe and Suitable for mounting of Wall / Pole With necessary Mounting arrangements including connecting up with three core twisted flexible copper conductor cable with suitable size, mounting Pipe/Bracket, Nut, Bolts and Accessories including disconnected & taking down oldunserviceable light complete all as specified and directed. |
| 52 | S & F Fire alarm control panel complying with BS EN 54 single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules |
| 53 | S & F Detectors complying with and type certified to EN -45 Addressable type multisensor detector with heat and smoke combination detector photoelectric/optical with base with self built intelligence as per IS: 11360 complete. |
| 54 | Supply, fixing and connecting annunciating devices , Addressable manual call point resettabletype complete. |
| 55 | Supply, fixing, Fire alarm sounders / sirens electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65DB to 120DB measured at 1.5mtr with sound output variation of +5 DB 500 mtrs range complete all as specified and directed |
| 56 | Supply and fix Remote response indicators complete all as specified and directed |
| 57 | Supply and fix PA system 6watt ceiling spekars |
| 58 | S&F 2x1.5 sq. mm +1x1.5 sq. mm earth wire for circuit/submain wiring alongwith earth wire, FRLS-H, PVC insulated copper conductor, single core in and including rigid, non metallic PVC conduit of suitable size on surface complete as per site requirement and as directed by Engr-in-charge |
| 59 | M&L for point wiring for controlled by one switch with PVC unsheathed single core multistranded FRLSH copper conductor cable of size 4 Sqmm (nominal area) in and including PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling including one run of PVC insulated FRLSH copper conductor cable of 4 Sqmm with green insulation as earth dolly for 6 pin, 16 Amp socket outlet on Independent board. |
| 60 | M&L for point wiring for controlled by one switch with PVC unsheathed single core multistranded FRLSH copper conductor cable of size 4 Sqmm (nominal area) in and including PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling including one run of PVC insulated FRLSH copper conductor cable of 4 Sqmm with green insulation as earth dolly for 6 pin, 16 Amp socket outlet on Independent board. |
| 61 | S&F switch piano flush type single pole one way 5 Amp (ISI Marked) |
| 62 | S&F switch piano flush type single pole one way 15 Amp (ISI Marked) |
| 63 | S&F socket out let 2 in 1, 5 pin 5 Amp flush type (ISI Marked) |
| 64 | S&F socket out let 2 in 1, 5 pin 15 Amp flush type (ISI Marked ) |
| 65 | Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated bus bar 240 Volts 4 way (2 + 2 way) single pole and neutral including taking down complete all as directed by Engineer-in-Charge. |
| 66 | S & F MCB, 6 to 32 Amp, SP, 240 Volt. complete all as specified and directed. |
| 67 | S&F MCB, 32 Amp, SPN, 240 Volt complete all as specified and directed. |
| 68 | S&F 2x2.5 sq. mm +1x2.5 sq. mm earth wire for circuit/submain wiring alongwith earth wire, FRLS-H, PVC insulated copper conductor, single core cable drawn through rigid, non metallic PVC conduit of any type or size on surface as per site requirement and as directed by Engr-in-charge |
| 69 | Supply, install,commissioning and testing of commercial Aircurtain unit for prevention of dust and conditioned air losses, single phase, 220 V, 50HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS -CRC 18 gauge square perforatedsuction grills,Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5m/sec air velocity at floor level for door opening as specified. |
| 70 | M&L for wiring for circuit/submain wiring with PVC unsheathed single core multistranded copper conductor cable of size 4 Sqmm (nominal area) in and including PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling including one run of PVC insulated FRLSH copper conductor cable of 4 Sqmm with green insulation as earth dolly for 6 pin, 16 Amp socket outlet on Independent board. |
| 71 | S&F sheet metal enclosures with socket plug Top /Modular AC Socket and heavy duty plug with metal box for AC, 3 Module, Double Pole MCB not less than 20 Amps, repturing capacity 10 kA including complete all as specified and directed. |
| 72 | S & F MCB, 6 to 32 Amp, SP, 240 Volt. complete all as specified and directed. |
| 73 | M&L for maintenance free chemical earthing of technology 3 mtr long 17.20 mm dia with 250-micron Copper coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 hole of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7 -8. Electrode should be duly tested and certified by CPRI. Govt of India for a min short circuit current of 25 KA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymerbody & cover dimensions-308mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab Complete all as specified and as directed.Note (i) Earthing is to be done infront of the Engr-in-charge.(ii) Test results of earthing to be submitted by the contractor for all earthings(iii) The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 2 (Two) years after certified date of completion and shall be deposited 2000/- per earthing as security deposit for a period of two(2) Years.(iv) Failing to maintain resistance of earthing less than 1.0 Ohm, New earthing to be provided by the contractor with out any extra cost.(v) Necessary earth work, excavation shall be carried out in any type of soil strata, returning filling in and making good surrounding arae complete. |
| 74 | M&L for copper strip 20 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground |
| 75 | M&L for flame proof point wiring with two single core FRLS-H PVC insulated & PVC unsheathed multi stranded copper conductor cable of size 1.5 Sqmm 1100 volts grade in and including stove enamelled steel conduit of size 20 to 25 mm with all accessories and one single core PVC insulated & PVC sheathed multistranded FRLS-H copper cable of size 1.5 Sqmm 1100 Volts grade as earth continuity conductor connected to common earth dolly, switch board complete incuding cutting chesses on wall/ floour/ ceiling etc. & making good the disturbed surface with 1:4 cement morter all as specified for one light / fan point controlled by one 5 Amps flameprrof switch one way complete. |
| 76 | Supply and fixing LED Light Fitting 1x18 Watt flame proof ,CMRI certified recommended for gas/vapour group of IIA &III B ,zone 1 and 2 and IP 65 Protection with die cast alluminium housing with heat resistant toughned glass with LED tube light, fixtures, driver holders ,connectors etc complete with all accesories prewired and including connecting with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.. |
| 77 | M&L switch flame proof rotory type with termination box in LM 6, 16 A,single phase 250 volts,complete all as specified and directed by Engr-in-Charge.. |
| 78 | S & F flame proof DB SPN 4 way DB including all fixing accessories complete all as specified and directed by Engr-in-Charge.. |
| 79 | S&F MCB SP, 6 to 32 Amps, 240 Volts, rupturing capacity 10 KA \\"c\\" Series complete all as specified . |
| 80 | S&F MCB DB 20 Amps, 240 Volts, breking capacity 10 KA complete all as specified . |
| 81 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level,connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr-in-Charge. |
| 82 | Supply and Laying in trenches / fixed to wall/ drawn in pipe/duct/laid in floor XLPE insulated screened,PVC bedded and sheathed and steel wire/strip armoured cable 1100V grade with stranded aluminum conductor of cross sectional area 10 Sq mm 2 core complete all as specified and directed. |
| 83 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as directed at site. |
| 84 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified. |
| 85 | Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified. |
| 86 | Supply and Laying of HDPE DWC pipe dia 40/32mm (outter/inner) with including fitting like couplers, bends, and end caps and etc consists of two layer, The outer layer smooth to facilitate easy cable pulling, Primarily used for underground cable ducting for electrical networks to provide mechanical protection with standards IS:16205 (Part-24) 2017 all as specified and directed by Engr-in-charge. |
| 87 | M&L for supply and fixing in repair air termination, single pointed aluminium rod 12 mm dia and 300 mm long all as specified and as directed |
| 88 | M&L in repair aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground comnplete all as specified and directed |
| 89 | M&L in repair for test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw and protected with 3mm thick enclosure completed closed for test point with 4 nos of screws with wall complete all as specfied and directed. |
| 90 | Supply and fix steel tubular swaged pole complete with cast iron base plate,finial taper plug,bolts,nuts & screws as specified type 410 SP-55 (11 mtr long) complete and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete complete all as specified and as directed by Engineer -in-charge |
| 91 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil /Hard/dense soil complete all as specified and as directed by the Engineer - in - Charge. |
| 92 | All as per item No 05 above but more than 1.5 Mtr and upto 2 mtr. |
| 93 | Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge. |
| 94 | M&L for PCC 1:4:8 type D2 using 40mm graded aggregate for pole / struts foundation etc all as specified and directed. |
| 95 | M&L for PCC 1:3:6 type C1 using 20mm graded aggregate for coping including necessary form work and fair finishing of exposed surface of concrete all as specified and directed. |
| 96 | Provn of new Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil.(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed(d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.(e) Requisite quantity of common salt and charcoal.(f) Testing of earthing. |
| 97 | M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLSH wire 2.5 Sq mm 1100 volts grade including and 2.5 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in PVC conduit incl cutting, chases in stone wall and match with the existing surface complete all as specified and directed.Note : Two run of 2.5 Sqmm cable and one run of 2.5 Sqmm cable as earth continuity conductor shall be measured & paid as one unit. |
| 98 | S&F switch piano flush type single pole one way 5 Amp (ISI Marked) |
| 99 | M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) |
| 100 | M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLSH wire 4.00 Sq mm 1100 volts grade including and 04.00 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in PVC conduit incl cutting, chases in stone wall and match with the existing surface complete all as specified and directed.Note : Two run of 04.0 Sqmm cable and one run of 6.0 Sqmm cable as earth continuity conductor shall be measured & paid as one unit. |
| 101 | Supply and fixing LED flood light 100watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 102 | Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral including taking down complete all as directed by Engineer-in-Charge. |
| 103 | S & F MCB, 6 to 32 Amp, SP, 240 Volt. complete all as specified and directed. |
| 104 | S&F MCB, 32 Amp, SPN, 240 Volt complete all as specified and directed. |
| 105 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I(ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order.(iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. |
| 106 | Supply and Laying in trenches / fixed to wall/ drawn in pipe/duct/laid in floor XLPE insulated screened,PVC bedded and sheathed and steel wire/strip armoured cable 1100V grade with stranded aluminum conductor of cross sectional area 10 Sq mm 2 core complete all as specified and directed. |
| 107 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as directed at site. |
| 108 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified. |
| 109 | Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified. |
| 110 | Supply and Laying of HDPE DWC pipe dia 40/32mm (outter/inner) with including fitting like couplers, bends, and end caps and etc consists of two layer, The outer layer smooth to facilitate easy cable pulling, Primarily used for underground cable ducting for electrical networks to provide mechanical protection with standards IS:16205 (Part-24) 2017 all as specified and directed by Engr-in-charge. |
| 111 | Supply & fixing in wall mounted servo-controlled Voltage Stabilizer for, single phase, naturally air cooled, indoor type & designed for input variation between 120V – 280 V with output voltage stabilized at 240V with accuracy of + 2.5% and of capacity 75 KVA complete all as specified and as directed.Make : V-Guard or equivalent model of Bluebird, Emerson, Volina |
| 112 | S&F sheet metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB of 20 amp capacity complete all as specified and directed by Engr-in-Charge |
| 113 | M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 6.00 sq mm 1100 volts grade including and 6.00 sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in conduit Note : Two run of 6.0 Sqmm cable and one run of 6.00 Sq mm cable as earth continuity conductor shall be measured & paid as one unit. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy