Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #54885597

Tender For Repair/Maint Of Internal Wiring Including Fixture And Fittings At Pattan Under Ge 969 Ews.

Issued by Statutory Bodies & Commissions/Committees · Pattan, Jammu And Kashmir
Tender Value
25 Lakhs
Estimated cost
Bid Submission
18 Apr 2026
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pattan → Jammu And Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Internal Wiring Including Fixture And Fittings At Pattan Under Ge 969 Ews.

BOQ

Name of Work:- REPAIR/MAINT OF INTERNAL WIRING INCLUDING FIXTURE AND FITTINGS AT PATTAN UNDER GE 969 EWS.
Sl. No. Item Description
1Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and as directed.
2M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.
3(a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way
4(b) One 3 pin 5 Amp switch socket outlet on independent board
5(c) One 3 pin 5 Amp switch socket outlet on same board with accessories
6M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor, complete all as specified and as directed.
7S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed.
8S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed.
9S&F Socket outlet 2 in 1, 3 pin, 5 Amps, box type complete all as specified and as directed.
10S&F Switch socket combination 2 in1, 3 pin,5 and 15Amp Box type ,universal complete all as specified and as directed.
11S&F in repairs stepped type electronic fan regulator for ceiling fan 1200/1400mm size,230 volts,6 Amps, complete all as specified.
12S&F in repairs Bell Push 5 Amp , flush type complete all as specified and as directed.
13Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, complete all as specified and as directed.
14S&F in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
15S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting, complete all as specified and as directed.
16Supply and fix LED Lamp 10W, complete all as specified and as directed.
17S & F Decorative ultra slim square profile LED lighting fixture 1x20 watt with extruded polycarbonate, environmental friendly, energy efficient, complete all as specified and as directed.
18S&F in replacement LED Mirror Light 10 W, Decorative ultra slim square profile with extruded polycarbonate, environmental friendly, energy efficient ready to use pack. suitable for surface mounting on a ceiling or wall, complete all as specified and as directed.
19S&F in repairs switch modular single pole one way 6 amp 240 volts,1 Module, complete all as specified and as directed.
20S&F in repair Modular Switch socket Combination 16A, 6 pin, 3 module 240 V,complete all as specified and as directed.
21S&F in repairs Modular socket 6A - 2/3 pin combined 2 module, complete all as specified and as directed.
22S&F in repairs modular fan regulator step type, 120W - 2 module, complete all as specified and as directed.
23S&F white cover plate with frame, 2 Module for point complete all as specified and as directed.
24S&F white cover plate with frame, 4 Module for point complete all as specified and as directed.
25S&F white cover plate with frame, 6 Module for point complete all as specified and as directed.
26S&F white cover plate with frame, 8 Module for point complete all as specified and as directed.
27S&F 6 W LED panel round/square type, Slim, compact, auminum die cast edge lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver including connecting cable of suitable size, complete all as specified and as directed.
28S&F 15 W LED panel round/square type, Slim, compact, auminum die cast edge lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver including connecting cable of suitable size, complete all as specified and as directed.
29Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 150/200/250mm, complete all as specified and as directed.
30S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires, complete all as specified and as directed.
31S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires, complete all as specified and as directed.
32S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 12 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires, complete all as specified and as directed.
33S&F Distribution board, SPN 2 way, single door, complete all as specified and as directed.
34S & F in repairs MCB SPN 40 to 63 amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning, complete all as specified and as directed.
35S & F in repairs MCB SPN 32 amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning, complete all as specified and as directed.
36S & F MCB SP 6 to 32 Amps, 240 Volts, C Curve complete all as specified and directed.
37S & F in repairs MCB TPN 40 amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning complete all as specified and as directed. .
38S & F in repairs MCB TPN 63 amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning complete all as specified and as directed. .
39M & L sub main wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 4 sqmm and one run of 4 sqmm cable and one run of casing capping shall be measured as one RM
40M & L sub main wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of casing capping shall be measured as one RM
41M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of necessary earth work, RFR and removal etc.
42S&F 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 6 sqmm all as specified and directed
43S&F 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 10 sqmm, complete all as specified and as directed.
44S&F 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 16 sqmm, complete all as specified and as directed.
45Supply and fix in repair capacitor 1.5/2 mfd suitable for 1200mm sweep ceiling fan, complete all as specified and as directed.
46Supply and fix heating element including rubber gasket & washer etc of capacity 1.5 KW suitable for existing make and shape (triangular/round/spiral) complete all as specified and directed.
47Supply and fix heating element including rubber gasket & washer etc of capacity 2 KW suitable for existing make and shape (triangular/round/spiral), complete all as specified and as directed.
48S&F Thermostate including rubber / PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 / 35 / 50 ltrs including taking down existing unserviceable thermostate, complete all as specified and as directed.
49S&F PVC connecting pipe 18\\"/24\\" long with brass adopters for cold/hot water and connecting up with complete for 25 /35 /50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe, complete all as specified and as directed.
50S&F base assembly complete with inlet, outlet thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket including taking down existing unserviceable base assembly, complete all as specified and as directed.
51Supply only Copper Conductor 1.5 Sqmm multistranded FRLSH, complete all as specified and as directed.
52Supply only Copper Conductor 2.5 Sqmm multistranded FRLSH, complete all as specified and as directed.
53Supply only Copper Conductor 6 Sqmm multistranded FRLSH, complete all as specified and as directed.
54Supply only Casig Caping of size 25mm, complete all as specified and as directed.
55Supply only following items complete all as directed by Engr-in-Charge.
56(a) Switch piano 5 Amp
57(b) Switch piano 15/16 Amp
58(c) Angle/ Batten holder
59(d) 5 Amps switch socket combination 3/5 pin type along with box.
60(e) 15 Amps switch socket combination 3/5 pin type along with box.
61(f) Modular switch flush type one way 6 Amp, 230 volts
62(g) Modular switch flush type one way 16 Amp, 230 volts
63(h) Modular socket 6 Amp 2/3 pin combined 2 module
64(i) Modular socket 6 /16 Amp 2/3 pin combined 2 module
65(j) Top plug 5 Amp socket complete
66(k) Top plug 15 Amp socket complete
67(l) Manual Changeover Switch 63 Amp complete
68(m) Insulation tape of size 32/40mm of Red, Yellow, Blue and Black colour
69(o) Supply Only SMD LED panel recess/surface suspended mounting 36 watt 2' x 2' LED ceiling light with extruded aluminium housing and milky diffuser including connecting up with twin core twisted flexible copper conductor cable with suitable size of 170-230 Volts, 50HZ, complete all as specified and as directed.
70(p) Supply Only SMD LED panel recess/surface suspended mounting 22 watt 1' x 1' LED ceiling light with extruded aluminium housing and milky diffuser including connecting up with twin core twisted flexible copper conductor cable with suitable size of 170-230 Volts, 50HZ, complete all as specified and as directed.
71(q) Supply Only round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed.
72(r) Supply Only Wall mounted Fan 400 mm sweep, complete all as specified and as directed.
73(s) Supply only 5W bright long range rechargeable torch with side light and Lithium ion battery for faster charging, complete all as specified and as directed.
74(t) MCB single pole 6 Amp, complete all as specified and as directed.
75(u) MCB single pole 10 Amp, complete all as specified and as directed.
76(v) MCB single pole 16 Amp, complete all as specified and as directed.
77(w) MCB single pole 20 Amp, complete all as specified and as directed.
78(x)MCB single pole 32 Amp, complete all as specified and as directed.
79(y)MCB double pole 40 Amp, complete all as specified and as directed.
80(z) MCB Double pole 63 Amp, complete all as specified and as directed.
81(aa) Supply only LED lights fitting 1X20 Watt , 4 Feet 220 Volt AC decorative box type with driver,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.
82(ab) Supply only LED Lamp 9 W 'T' type, complete all as specified and as directed.
83(ac) Supply only LED Lamp 20 W 'T' type, complete all as specified and as directed.
84(ad) Supply only Track light bed side decorative type, complete all as specified and as directed.
85Note:- Schedule of credit Rs 62,985.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 54885597
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 18-04-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Internal Wiring Including Fixture And Fittings At Pattan Under Ge 969 Ews.
Basic Detail
Tender No CA NO 969 WS- /2026-27
Bidding Type Tender
Location
City Pattan
State Jammu And Kashmir
Key Dates
Publish Date 28 Mar 2026
Submission Date 18 Apr 2026
Open Date 20 Apr 2026
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Available
Document List
BOQ_849346.xls
dadf3550-d4de-4e10-a013-2aded38a94c7.html
TENDER.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_849346.xls

html

dadf3550-d4de-4e10-a013-2aded38a94c7.html

pdf

TENDER.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders