| 1 | Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. (PWD SI No 645) |
| 2 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 100 to 120 Watt. Confirming to IP 65 protection complete in all respect.SI No 1453/2018 CAT-AAA |
| 3 | Supply and Fixing of M/s Bracket 9 Cirecular/Square/Double Aram Shape) for Fixing of four number LED Flood Light on Top of Pole complete of work with Labour T & P etc. (PSR) |
| 4 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (SI No 501/2018) 4.1 (a) 16 Sq.mm. 4 Core |
| 5 | 4.2 (b) 35 sqmm 3-1/2 core |
| 6 | Supply and fixing of plain or pin type copper tin plated cable socket ( Lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. (SI No 504) 5.1-- 10 sq. mm (504 C) |
| 7 | Suplly and Fixing of DWC HDPE Pipe along with all acessories Like socket, band, coupling etc. confirmin to IS 14903 Part-ii complete with fixing and cutting jointing etc. (63 mm OD and ID 51 mm nominal) DSR/2022/(E/M) Item No-14.16.1) |
| 8 | S/B Decduct in item no-501 (h) and 501 (J to when cables is passed throught G.I./M.S. or hume Pipe in road crossing or along the wall the cost of the G.I. Pipe hume is to be extra when and where required. (PSR) |
| 9 | S/B of Earth rod 20 mm dia 2.5 mt long including GI wire 7/16 SWG to connected earth rod and earth clamp on pole, 3 mtr long steel conduit to carry earth wire along the jpole complite as per approved of E/Ic. (PSR) |
| 10 | Supply and wiring of Submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia. heavy guage rigid steel conduit on surface, with one number 14 SWG copper earth continuity wire etc, complete in all respect. SI No 1301 (B) |
| 11 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve SI No 1002 CAT-A |
| 12 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. (PWD SI No 725 B) |
| 13 | Supply and fixing 40 A TPN capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. (PWD SI No 807 f ii) |
| 14 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable ockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only.As per PWD schedule 2018 SI No. 804(e) |
| 15 | Supply & fixing of 12.5 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 310 mm base plate 25 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes 0.75 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. |
| 16 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 140 to 150 Watt. Confirming to IP 66 protection complete in all respect. SI No 1454. CAT - AAA |
| 17 | Operation & maintanence of street light installed for 3 year/365 days per year. (a) Electrician Garde-II licence holder with suitable toolkit. (01x0.5x470 per day). |
| 18 | Operation & maintanence of street light installed for 3 year/365 days per year. (b) Helper/Labour semi skilled (01x0.5x430 per day). Please Enable Macros to View BoQ information |