| 1 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. BDW 8 46.09 - As directed by Engineer in charge.(SSR No.: 46.09)- |
| 2 | Removing ventilators /Grills and small windows with frame and stacking the materials with all leads, lifts etc. complete. BDW 8 46.16 - As directed by Engineer in charge.(SSR No.: 46.16)- |
| 3 | Removing cement or lime plaster including disposing of the spoils as directed with all leads, lifts etc, complete. BDW 8 46.2100000000001 - As directed by Engineer in charge.(SSR No.: 46.21)- |
| 4 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.)By Mechanical Means BDA 1 21.02 - Bd.A.1 Page No. 259(SSR No.: 21.02)- |
| 5 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. BDA 21.40 - As directed by Engineer in charge.(SSR No.: 21.40)- |
| 6 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzit/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand BDE 1 24.01 - Bd. E. 1 Page No. 287(SSR No.: 24.01)- |
| 7 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand BDF 3 25.50 -(SSR No.: 25.50)- |
| 8 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters forR.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. BDF 17 26.33 -Bd. F. 17 Page No. 306 /I.S. 456 (2004(SSR No.: 26.33)- |
| 9 | Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) BDE3 24.16 - Bd.E. 3/Page No. 288/I.S. 456 (2000)(SSR No.: 24.16)- |
| 10 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. BDF 27.01 41 26.116 -(SSR No.: 27.01)- |
| 11 | Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqm /kg with two coat using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. BDJ31.09 - As directed by Engineer in charge.(SSR No.: 31.09)- |
| 12 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. BDL 3 32.11 - Bd.L.3 Page No. 368(SSR No.: 32.11)- |
| 13 | Providing internal cement plaster 25mm thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick or stone surfaces, in all positions including scaffolding and curing etc.complete. BDL 4B 32.09 - Bd.L.4 Page No. 368(SSR No.: 32.09)- |
| 14 | Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. BDL 18 32.21 - Bd. L. 18 Page No. 373(SSR No.: 32.21)- |
| 15 | Providing and fixing of colour coated Zincaluminium( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated withAluminium-Zinc alloy (55% aluminiumm 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyster paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 mm, comprising of nominal 25mmexterior coat on top surface and nominal10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with sublet square fluting in the five pan at nominal 180-250 mmcenter-to-center. The end rib shall be designed for anti-capacity groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) 301 mm to 600 mm girth (Surface Width). BDR 38.34 - As directed by Engineer in charge.(SSR No.: 38.35)- |
| 16 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. BDC 2 23.01 - Bd.C.2 Page No. 275(SSR No.: 23.01)- |
| 17 | Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete.Spec. No. : As directed by Engineer-in-charge.BDC 23.07 - B-18 Page No. 78(SSR No.: 23.07)- |
| 18 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. BDT 40.01 - As directed byEngineer in charge.(SSR No.: 40.01)- |
| 19 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. [REFIXING RATE AS/SSR] BDT 40.01 - Asdirected by Engineer in charge.(SSR No.: 40.01)- |
| 20 | Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. BDM 33.67 - Bd. M-12 page No. 385(SSR No.: 33.67)- |
| 21 | Providing and laying ceramic tiles of having size30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. BDM 12 33.25 - Bd.M.12 Page No. 385.(SSR No.: 33.25)- |
| 22 | Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 60 mm thickness of having a strength of 300 kg/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete BDM33.51 - A directed by Engineer in charge(SSR No.: 33.51)- |
| 23 | SUPPLY AND FIXING M20 GRADE PRECAST BENCH 1.35M LONG X 0.46 WIDE WITH TWO HEAVY LEGS WITH NECESSARY REINFORCEMENT WITH LOADING UNLOADING COMPLETE FITTING WITH 3 COATS OF OIL PAINT AS DIRECTED BY ENGR IN CHARGE [AS/LOWEST QUOTATION](SSR No.: ) |
| 24 | Providing and Fixing mat/glossy finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) BDW 40.08- As directed by Engineer Incharge(SSR No.: 40.08)- |
| 25 | Providing and laying in walls/ceilings/floors 50 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 5.17 kg/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. BDV 5 43.06 - Bd.V.5 Page No. 551(SSR No.: 43.06)- |
| 26 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. BDV 5 42.57 - BD.V 5 page 551 and as directed by Engineer in charge(SSR No.: 42.57)- |
| 27 | Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. BDV 9 41.45 -Bd.V.9 Page No. 555(SSR No.: 41.45)- |
| 28 | Drilling of 150 mm 6\\" dia borewell by ring machine as directed.[as per sanction rate ](SSR No.: ) |
| 29 | Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with novolt coil and overload element with necessary materials and connected to supply(SSR No.: 12-4-2) |
| 30 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 31 | Supplying & erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.(SSR No.: 12-4-8) |
| 32 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (SSR No.: 1-3-1) |
| 33 | Supplying and erecting programmable digital almanac timer microcontrollerbased with real time clock to operate on derived switching “ON” and switching“OFF” street light as per daily sunset and sunrise respectively automaticallyhaving 4 digit LED continuous time display, relay output 230 V / 10A with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided M.S. box.(SSR No.: 4-8-6) |
| 34 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB(SSR No.: 5-4-7) |
| 35 | Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 120 to 475 LPM discharge at 36 to 10 m head & discharge & delivery Pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP(SSR No.: 12-2-2) |
| 36 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(SSR No.: 5-3-2) |
| 37 | Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 38 | p/f 3mm thk acp panel boards on extg.masonary pillars on 6 mm thk waterproof fiber boards with computrised words/matter/pictures as per given matter as directed by engineer in charge [ as/lowest quotation from market](SSR No.: ) |
| 39 | P/a waterproof special paint colouring to existing murals on bbm pillars as directed by engr in charge(SSR No.: ) |
| 40 | Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (To be executed with prior approval of Superintending Engineer) BDA 13 21.39 - Bd.A.13 Page No. 264(SSR No.: 21.39)- |
| 41 | GARDEN SOIL:-Supplying on site garden soil well sieved80 % to pass through I.S. sieve of 10 mm size free fromstones rubbish like dried grass roots and other such materials.The soil should be fresh from quarry. The color of the soilgenerally is red. The soil will be measured by measuring box.(Farma)Item includes Transporting, loading -unloading etc(.Lead charges per 15 km. considered Excluding royalty.) DSR PUNE REGION(SSR No.: DSR PUNE REGIOSSR-PARKS AND GARDEN 2022-23 |
| 42 | Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50m. to 300m. inclusive from the site of excavation to the site of deposition as directed. MORTH 305 2.24 -MORTH 501(SSR No.: 2.24)- |
| 43 | Providing and fixing 50 mm. dia. medium class G.I.pipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in c.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete. BDC 23.05 - As directed by Engineer in charge.(SSR No.: 23.05)- |
| 44 | Providing and applying two coats (exterior quality) of flat oil paint of approved colour and shade to the plastered surface in buildings and workshops including scaffolding if necessary, cleaning the surface and preparing surface etc. complete. (excluding primer coat) BDO 7 35.11- Bd.0.7 Page No. 406 |
| 45 | Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surface including cleaning ,preparing the plaster surface applying primer coat, scaffolding if necessary and watering the surface for two days etc complete. Note :- For item no.15 to 18 pripr approval of superintending engineer will be necessary BDO 35.26 As directed by engineer in charge Contractor has to quote on Work Portion Only Please Enable Macros to View BoQ information |