| 1 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL DSR No. 7-1-17 |
| 2 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL DSR No. 7-1-28 |
| 3 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL DSR No. 7-1-29 |
| 4 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW DSR No. 1-3-2 |
| 5 | Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW DSR No. 1-3-1 |
| 6 | Supplying and erecting modular type switch 16A on provided plate and box with wiring connections complete. DSR No. 1-6-2 |
| 7 | Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete. DSR No. 1-6-11 |
| 8 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module complete. DSR No. 1-6-29 |
| 9 | Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mA Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 Hrs with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20 % having useful life of minimum 25000 Hrs with over heat protection with minimum 2 years as per specification No. FG-IDF/LED. DSR No. 2-1-22 |
| 10 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V,inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FGODF/ SL. DSR No. 2-3-4 |
| 11 | Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FGODF/ FL. DSR No. 2-3-18 |
| 12 | Supplying and erecting integrated LED flood light fitting Max. 100W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with Ushaped bracket with minimum 2 Years warranty as per specification No. FGODF/FL. DSR No. 2-3-15 |
| 13 | Supplying and erecting PVC box trunking of size 100x50mm with accessorieson wall/ceiling as per specification no. WG-MA/BOX . DSR No. 1-2-14 |
| 14 | Supplying and erecting HMS PVC conduit 25mm dia. with PVC accessories onwall/ceiling as per specification no. WG-MA/CON. DSR No. 1-2-4 |
| 15 | Supplying and erecting HMS PVC conduit 20mm dia. with PVC accessories onwall/ceiling as per specification no. WG-MA/CON. DSR No. 1-2-3 |
| 16 | Supplying and erecting iron work, sheet metal work consisting of MS sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted withone coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the site engineer. DSR No. 6-1-19 |
| 17 | Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5 x 3.65 x 3.25 mm thickness (5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 113 kg) as per specification no. OH-PL/STP DSR No. 8-1-3 |
| 18 | Making Cement concrete foundation including excavation (60 x 60 x 150)cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45)cm /45cm dia. x 45cm height plinth duly plastered, with necessary curing and finishing complete. (above 6m to 9m poles) DSR No. 16-3-3 |
| 19 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. DSR No. 7-6-9 |
| 20 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP DSR No. 9-1-4 |
| 21 | Supplying and erecting Street light bracket for erection of Double fitting on tubular welded pole with 40 mm. dia 1.0 m long “B” grade G.I. pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. FG-BKT/SLB DSR No. 2-6-8 |
| 22 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for 4 pole incoming 250A, 12 ways 4 pole outgoing, up to 100A MCCBs on iron frame,as per specification no. SW-MCCBPB. (Excluding MCCBs) DSR No. 5-7-5 |
| 23 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TPMCBs total 12 ways/36 poles, with door, 1.2mm thickness surface/flush mounted, IP43 Protection on provided iron/GI frame (vertical busbar type) as per specification no.SW-MCBDB DSR No. 5-4-6 |
| 24 | Supplying, erecting & marking FP MCB 6A to 32A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB DSR No. 5-3-12 |
| 25 | Supplying, erecting & marking DP MCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-MCB DSR No. 5-3-9 |
| 26 | Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact.MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB DSR No.5-5-3 |
| 27 | Supplying, installing and testing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l.cover with minimum 25 kg Carbon based environment friendly back fill ground ehancing compound complete with all accesories of copper materials & recordingthe results as per specification no EA-EP/EF DSR No.9-1-6 |
| 28 | Point wiring for light/fan/bell in 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification no. WG-PW/SW DSR No.1-7-3 |
| 29 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1400 mm, Max. Energy Consumption of 28W having service ratio (CMM/W)of Min. 8, PF>0.9, THD<10% with IR remote control, Temperature Rise of Max. 40 deg.C, having external mounted control PCB completely erected in positionas per specification no. FG-FN/CF. DSR No.2-9-23 |
| 30 | Supplying and erecting aluminium strip of required sizes used for earthing or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint as per specification no EA-EP. DSR No.9-2-1 |
| 31 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge (C class) 40 mm dia 1.2mtr copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball of size 100mm as air terminals duly threaded in copper pipe erected on provided foundation in an approved manner as per spicification no. EA-LA DSR No.9-3-1 |
| 32 | Supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator, metallic blades, overheat protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and hand shield type 3 pin 5A. plug top complete with moisture proof treatment and ‘E’ class insulation. DSR No.2-9-8 Please Enable Macros to View BoQ information |