|
| 1 | Dismantling of brick tiles or concrete tiles single layers on roof and rubbish off the premises to a distance not exceeding 500 mtr including stacking of servicable brick tiles complete all as specified and as directed. |
| 2 | Demolition of mud phuska on roofs, any thickness including mud plastering,whether full thickness removed or only a part thereof and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and as directed. |
| 3 | Disconnecting existing water tanks exc 500 and not exceeding 1000Ltrs cap, setting aside (or lowering if required) including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position including writing date of cleaning on each tank with white paint, height/size of letters/figures not less than 10cm in height, complete all as specified and directed.” |
| 4 | Dismantling water tanks exceeding 500 litres and not exceeding 1000Litrs cap and removing to store complete all as specified and directed. |
| 5 | Demolition of Brick work or stone boulder masonry/PCC block masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework & precast concrete articles and disposing off rubbish outside MD land complete all as specified and directed. |
| 6 | Taking down cement plastering of any thickness on brick, concrete or stone walls, partitions, ceilings etc including raking out joints, hacking for key, scrubbing down with water etc, and rmoving debris out side MD land complete all as specified and as directed. |
| 7 | Taking down chowkats or frame without taking off shutter from the frame n.exc 1.50 Sqm each from the frame and removing from site, including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3 including necessary brickwork, complete all as specified and as directed. |
| 8 | Taking down chowkates / frame without taking off shutter exceeding 1.50 Sqm not exceeding 4 Sqm each. from the frame and removing from site, including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3 including necessary brickwork, complete all as specified and as directed |
| 9 | Taking down Shutters of any description exceeding 1 sq. m and not exceeding 2 sq. m each complete all as specified and as directed |
| 10 | Taking down and refixing in the same opening Shutters of any description not exceeding 1 sqm each complete all as specified and as directed |
| 11 | Taking down and refixing in the same opening Shutters of any description but exceeding 1 sqm but needing exceeding 2 sq. m each, complete all as specified and as directed |
| 12 | Resecuring easing and adjusting without taking down of shuter exceeding. 1 sqm not exceeding 2 sqm each with out taking down complete all as specified and as directed |
| 13 | Resecuring easing and adjusting without taking down of shuter not exceeding. 1 sqm with out taking down complete all as specified and as directed |
| 14 | Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry @ 3.0 Kg/Sqm complete all as specified and as directed |
| 15 | M&L for PCC 1:2:4 type B-0 using 12.5mm graded mechanically crushed stone aggregates as in padding on roof to maintain the required slope & finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 16 | M&L for Hydraulically pressed Cement Concrete tiles plain size 250x250x19 mm/300x300x19 mm laid over and including 15mm thick screed in CM 1:4 with WPC & pointed in CM 1:3 mixed with crude oil ( WPC as per manufacturer's instruction shall be deemed to be included in unit rate quoted) Note :- water profiing treatment will be carried out through approved applicator as approved by GE. Please Enable Macros to View BoQ information |
| 17 | M&L for Hydraulically pressed Cement Concrete tiles plain size 250x250x19 mm/300x300x19 mm laid over and including 15mm thick screed in CM 1:4 with WPC & pointed in CM 1:3 mixed with crude oil ( WPC as per manufacturer's instruction shall be deemed to be included in unit rate quoted) Note :- water profiing treatment will be carried out through approved applicator as approved by GE. Please Enable Macros to View BoQ information |