| 1 | LIFT - MRL TYPE:Supply,Installation Testing & Commissioning of Customized 12 Nos (G+3) – 06 Passenger (408 Kg) MRL Lifts at Transit Accommodation Mirhama Kulgam (excluding all the civil works). The lift shall be suitable for 06 passengers, of standard design having speed of 1 m/s serving from Ground, 1st, 2nd & 3rd floor i.e. 04 stops and 04 landings. The elevator shall be of state of art technology, energy efficient drive and all its components/ accessories shall conform to relevant IS standards. • (The Defect Liability Period (DLP) of the equipment shall be 02 years.• Machine – Gearless machine located in the shaft on the top of guiderails• Power Supply – 400/415 V (3 Phase AC)• Control – Simple Collective Selective Control (VVVF regenerative drive)• Minimum Hoist way dimensions - - 1800 mm (W) x 1800 mm (D) • Overhead - 4250mm • Required Pit depth - 1500mm• Landing door – Centre door opening in stainless steel hairline. • Door opening :Ground, Ist, 2nd & 3rd floor on same side• Car design - Stainless steel in hairline finish.• Handrail - Round handrail in stainless steel finish provided on rear wall of car.• Alarm button in car operating panel with battery back-up.• Automatic operation for car fan.• Anti-nuisance (empty car)• Anti-nuisance (car call cancellation at direction reversal)• Blower fan in car for ventilation• Braille on push buttons• Door open and door close buttons in car operating panel.• Door closing retries and Door Nudging• Emergency light• Full load by-pass• Infra–red screen for car door• Intercom Provision With Instrument• Motor overheat protection.• Overload function with audio-visuals indication in car operating panel.• Phase failure and phase reversal protection.• Automatic rescue device in case of power failure.• Attendant control.Car arrival chime on car top/voice synthesizer.• LCD dot matrix scrolling display in car operating panel.• LCD matrix scrolling display in landing operating panel on all floors.• Fireman control and Fire Emergency Return. |
| 2 | Providing / Fitting of 3.5 core, 240 sqmm XLPE insulated, PVC sheathed armoured Al cable other required accessories cable glades,clamps,saddles for proper connections and fixings as per standard practice to be laid as per the CPWD guidelines. |
| 3 | Providing / Fitting of 3.5 core, 120 sqmm XLPE insulated, PVC sheathed, armoured Al cable other required accessories cable glades,clamps,saddles for proper connections and fixings as per standard practice to be laid as per the CPWD guidelines. |
| 4 | Supply, Installation and Testing & Commissioning of Distribution Busbar enclosed in suitable sized CRC Enclosure,SWG 16, with IP-65 rating to prevent ingress of water and comprising of below mentioned items. The panel will be mounted on the angle iron base frame which shall be fixed on the DG foundation.1) 400A Aluminum 4 Pole Bus Bar –01 set |
| 5 | DG SET Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or latest applicable norms of rating 160 KVA , 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine:Tourbocharged Diesel engine 4 stroke water cooled,multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for aboveoutput of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.(B) Engine mounted Instrument Panel fitted with and having digital display Plate for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication (vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- insulation(D) Base Frame As per CPWD specifications(E) FUEL TANK: As per CPWD specifications (F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in tothe atmosphere and the temperature rise inside theenclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be waterproof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better normsetc. and as per CPWD specifications.(I) AMF Panel:Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for 160 KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 polemotorised electrically operated draw out with cradletype 3 position ACB/ MCCB with electronic release forO/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH,PF.6. LED Indicating lamps for load on mains and load on set 7. Fuse/ MCB for instruments 8.Battery charger, complete with transformer/ rectifier, all interconnections, testing, commissioning and handing over complete as per CPWD specifications and Engineer-in-Charge approval. |
| 6 | Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories\ and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7metre long etc. (but with out charcoal or coke and salt) complete as required. As per IS:3043. |
| 7 | Add extra for using salt and charcoal / coke for G.I.plate or copper plate earth electrode as required including excavation and refilling the pit in all type of soil. |
| 8 | GI Strip of following sizes 25 x 6 mm: Supply and laying 25mm X 6mm G.I. strip at 0.5 metre below ground level as strip earth electrode including jointing etc. as required |
| 9 | Supply and fixing PVC conduits required confirming to IS 9537 (Part-3), ISI marked along with the accessories in concealed systemetc. as required.PVC. conduit 50 mm |
| 10 | Foundation & EnlcosureEarth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavatedAll kinds of soil: |
| 11 | P/L stone soling hand packed on level incl ramming with heavy rammers incl carriage upto site |
| 12 | Providing and laying in position cement concrete including curing but excluding the cost of centring and shuttering.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 13 | Providing and laying in RCC including curing but excluding the cost of centring and shuttering1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 14 | Reinforcement for RCC Work incl straightening,bending, cutting placing in position and binding |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundation |
| 16 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (welded) |
| 17 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gram/m2 |
| 18 | Providing and fixing angle iron frames of mild steel Angle sections of size 25x25x5 mm and 40x40x5 mm for Door. The job including welding of MS flat strips of (25x 3) mm with Angle Iron frame including fixing door and necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 19 | Providing and Fixing of Wire Mesh (Mesh size 50x50)mm & wire dia 2.2mm. The job including fixing of wire mesh with flat MS strips welded with angle irons frames as well as covering open portion of truss to ensure proper closing of whole job as direct by EIC. |
| 20 | Supply, installation, testing & commissioning of 3 Phase-45 KVA servo-stabilizer including oil and all allied electrical acessories with earthing.The stabiliser should have following specifications:a) Capacity:45 KVA, 3-phase unbalanced typeb) Input: (100-265) V AC P-N; (180 - 460) V AC P-Pc) Output: 415 V ± 1% - phase to phase d) Supply: 3 phase, 4 wires, 50Hze) Operation: Automatic f) Duty cycle: Continuousg) Transformer windings: Copper wound on CRGO laminations as per IS specificationsh) Cooling: Oil cooledi) Efficiency: Better than 98% at full loadj) Overload capacity: 15% for continuous 4 hoursk) Waveform distortions: Nill) High speed voltage correction: up to 8V to 20V per secondm) Protections: Under voltage, Over voltage and Overload with time delayn) Other features: LED indicators, Digital AC ammeter, AC voltmeter, Frequency meters, Single phase preventer, Stabilizer by-pass arrangement.o) Incomer MCCB 200A TPN (36kA breaking capacity) of reputed make preferably L&T/ABB/Schneider |
| 21 | Supply, Installation and Testing & Commissioning of Control Panel enclosed in suitable sized CRCA 16 SWG Powder coated Enclosure with IP-65 Rating to prevent ingress of water and comprising of following items.1: Three phase 4-pole 200A ATS of reputed make preferably L&T/ABB/Schneider.2. 200A Aluminum 4 Pole Bus Bar –01 set 3. Digital Voltmeter with Selector Switch 4. Digital Ammeter with Selector Switch & CTs (3 set for 3 outgoing feeders)5. Phase Indicator Set 6. 63A Four Pole MCBs (36 kA breaking Capacity)- of reputed make preferably L&T/ABB/Schneider (3 No.s for 3 outgoing feeders)7. P/F of feedback mechanism for autostart of DG set during mains failure including wiring from control panel upto DG set AMF panel. |
| 22 | Providing / Fitting of 3.5 core, 150 sqmm XLPE, PVC sheathed, armoured Al cable from Distribution Transformer to Servo Stabilizer with other accessories of suitable rating to be laid as per CPWD guidelines. |
| 23 | Providing / Fitting of 3.5 core, 25 sqmm XLPE, PVC Sheathed, Al cable from Control Panel to individual lifts with other accessories of suitable rating to be laid as per CPWD guidelines. |
| 24 | Miscellaneous P/F of ladder from level 2 platform till top of the lift shaft. |
| 25 | Supply,installation,and wiring of IP65-rated not less than 10 watt LED bulkhead lights of reputed make in the lift shaft, including secure mounting, conduit wiring, connection, testing and commissioning as per approved specifications. |
| 26 | FPS Brick work in cement mortar of 1:4 (1 cement, 4:coarse send) of 7.5 class designation in superstructure. |
| 27 | Providing and laying 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand) on wall surfaces and providing complete finishing system over the same area comprising of 2 mm thick wall putty and two coats of acrylic emulsion paint of approved make and shade including primer coat, surface preparation, curing, scaffolding, all leads and lifts, materials, labour and all incidental charges, complete as per specifications. |
| 28 | Comprehensive Annual Maintenance Contract (CAMC)“The above lifts, including their DG set and servo voltage stabilizers, shall be under a Defects Liability Period (DLP) of two years. After completion of the DLP, a Comprehensive Annual Maintenance Contract (CAMC) for one year shall be provided, covering routine, preventive, and breakdown maintenance, including repair or replacement of worn-out parts with minimal downtime. All repaired or replaced items under CAMC shall be warranted and guaranteed.” Please Enable Macros to View BoQ information |