| Sl. No. | Item Description |
| 1 | Excavation over areas in hard/dense soil n exc 1.5 m depth and getting out etc complete all as specified and directed |
| 2 | Excavation over areas in soft disintegrated rock n exc 1.5 m depth and getting out etc complete all as specified and directed |
| 3 | Excavation over areas in soft and distengrated rock exc 1.5 m but n exc 3.0m depth and getting out etc complete all as specified and directed |
| 4 | Excavation over areas in had rock (Manjeera rock) exc 3.0m but n exc 4.5 m depth and getting out etc complete all as specified and directed |
| 5 | Excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in Hard dense soil complete all as specified and directed |
| 6 | Excavating in trenches, n exc 1.5m wide, exc 1.5m but exc 3m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in soft/integrated rock etc complete all as specified and directed. |
| 7 | Excavating in trenches, n exc 1.5m wide, exc 1.5m, exc 1.50m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in had rock (Manjeera rock) etc complete all as specified and directed. |
| 8 | Returning, filling in, including spreading, levelling, watering & well ramming in layers n. exc 25 cm excavated soil/soft ordinary rock/ soft disintengrated rock/Hard dense soil/had rock (Manjeera rock) complete all as specified and directed |
| 9 | Removing excavated soil/soft ordinary rock/ soft disintengrated rock/Hard dense soil/had rock (Manjeera rock) material exc. 250 m but n exc. 500 m and depositing where directed Complete all as specified and directed. |
| 10 | M & L in hard core of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface Complete all as specified and directed. |
| 11 | M & L for PCC (1:2:4) type B-1, (using 20mm graded stone agg) as in foundataion fiiling & mass concrete finished even and smooth Complete all as specified |
| 12 | M&L RCC (1:11/2:3) type A-1 (using 20mm graded stone agg as in roof slab supported on walls Complete all as specified and directed. |
| 13 | M&L for PCC 1:5:10 type E-2 (using 40mm stone graded agg) as in foundation filling and mass concrete etc.Complete all as specified and directed. |
| 14 | M&L for PCC type C-2 (1:3:6) using 40mm graded stone agg as in lean concrete, sub base or mass concrete, in foundation filling etc all as specifed and directed. |
| 15 | M&L PCC 1:3:6 type C-2 using 12.5mm graded agg as in bedding or surface channel and drains complete all as specifed and directed. |
| 16 | M&L PCC 1:2:4, 50mm thick type B0 using 12.5mm graded stone aggregate as in padding of roof surfaces finished even and fair without using extra cement complete all as directed by Engr-in-Charge. |
| 17 | M&L PCC 1:2:4 type B0 (using 12.50mm graded stone agg) as in coping, rounded or chamfered on edge complete all as specified and directed. |
| 18 | M&L for cement concrete in type B-1 1:2:4 (using 20mm graded stone agg) as in bed blocks etc complete all as specified and directed. |
| 19 | M&L Providing precast cement concrete type B1, 1:2:4 (using 20mmg graded stone agg) as in manhole covers/baffle walls etc all as specified and directed. |
| 20 | M&L for RCC (nominal mix) type B0 1:2:4 (Using 12.5mm graded stone agg) as in slab supported on wall complete all as specified and directed. |
| 21 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped end etc. |
| 22 | Supply only liquid water proofing complete all as specified and directed. |
| 23 | M&L for old size brick work with fly ash bricks straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified. |
| 24 | M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius old size brick built in in CM (1:6). Complete all as specified and directed. |
| 25 | M&L for Cutting chases, pinning in, making good to facings where required and pointing in CM(1:3) to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth in stone/concrete/brick wall Complete all as specified and directed. |
| 26 | M&L 18-20mm thick Granite (of any tpe) work (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platforms and like in CM(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite Complete all as specified and directed. |
| 27 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200m thick (Horizontal or sloping) Fair finished surfaces of concrete flat Complete all as specified and directed. |
| 28 | Use and waster for formwork for fair finished flat surface as in soffits of suspended slabs thickness exc 200mm, complete all as specified and directed. |
| 29 | M&L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide rough finished surface of concrete Complete all as specified and directed. |
| 30 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs exc 5cm but n exc 10 cm wide & sides of RCC/PCC bands in walls, horizintal or sloping & similar work exc 5cm but n exc 10cm wide Roughed finished surface of concrete Complete all as specified and directed.. |
| 31 | Taking down Chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) Complete all as specified and directed. |
| 32 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium Carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Complete all as specified and directed. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made |
| 33 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus ofelasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S Sscrews shall be paid separately) |
| 34 | S&F 200mm long aluminium anodised barrel tower bolts fo extruded section and fixed as specified and as directed. |
| 35 | S&F 150mm handles cast type anodised complete all as specified and directed. |
| 36 | S&F 600mm long Aluminium anodised 20mm dia D type, 60cm long between flange fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specifeid and directed. |
| 37 | S&F stainless steel wire cloth, 0.36 nominal dia of wire & average width of aperture 1.40mm and fixed. Complete all as specified and directed. |
| 38 | S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 ,complete all as specified and directed. |
| 39 | M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality ,complete all as specified and directed. |
| 40 | S&F for Mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends, rungs and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed |
| 41 | S&F Fe-290 (Gde E-165) Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) ,complete all as specified and directed. |
| 42 | M&L for powder coated (minimum thickness of powder coating 50 micron) aluminium frame of standard section for doors, windows, ventilators and partitions with double rebates including jointing cleat for fixing etc complete all as specified. |
| 43 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 44 | Material and labour for suspended false ceiling using anodized aluminium snap grid frame work, including hanger 6mm dia GI (Upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mmlong complete calcium silicate board 12mm tjhick as per manufacturer instruction all as specified and directed by Engr-in-Charge. |
| 45 | M&L 0.60mm thick Pre-painted galvalume zinc coating GI based corrugated steel sheet of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping scrws as specified with her cap headed self drilling/tapping stainless steel screws M6, 60mm long with 3mm EPDM seal washer etc all inclusive of labour scaffolding. T&P and sundries etc including ride of same profile with min overlap of 300mm on either side complete all as speciife and directed. |
| 46 | M&L 0.60mm thick Pre-painted galvalume zinc coating GI based plain steel sheet of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping scrws as specified with her cap headed self drilling/tapping stainless steel screws M6, 60mm long with 3mm EPDM seal washer etc all inclusive of labour scaffolding ,complete all as specified and directed. |
| 47 | M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven polyster reinforement (wt. not less than 150 gms/sqm) shall be laid by torch application method and overlapped by 100mm in all sides including water proofing membrane to be erminated on parapet wall in a V groove of size 25mmx25mm atleast 300mm above FFL which should be sealed with polyer mortar and applying evenly a tack coat of industrial bitumen 85/25 2 1.20kg/sqm including cleaning of surface to receive PCC tiles as directed by Engineer-in-Charge. |
| 48 | M&L rounding to edge of stone slabs one edge, such as steps, cooking plateform and other similar situations. |
| 49 | M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone agg) as in sub base of floor and path, plinth protection etc complete all as specified and directed. |
| 50 | M&L for 100mm thick cement concrete type D-2, 1;4:8 (using 40mm graded stone agg) as in sub-floors, sub-base, floors and pavings. Compelte all as specified and directed. |
| 51 | M&L for Applying brushing neat cement slurry with 3.0kg/sqm all as specifed and directed. |
| 52 | Dismantling floor, hearth or wall tiling including cement mortar bedding (incl backing), removing serviceable tiles to store and rubbish off the premises |
| 53 | M&L Machine cut kota stone slab flooring mirror polishing 18-20mm of size 595x595mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including screed bed 20mm thick in cement mortar 1;6. Complete all as specified and directed. |
| 54 | M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado & pillar laid over cement screed and jointed with over a 10mm thick plaster in CM 1:3 all as specified and directed. |
| 55 | M&L for 25mm thick PCC 1:2:4, type B-0 (using 12.50mm graded agg) as in sub-base of floor tiles. Complete all as specified and directed. |
| 56 | M&L Glazed ceramic coloured tiles 450x300/300x600x7mm thick in size, set and on vertical surfaces such as skirting,dado etc over and including 10mm thick rendering in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Complete all as specified and directed. |
| 57 | M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18sqm but not exc 0.38 sqm as in skiting, rendering 10mm thick in CM 1:3 on walls etc set and jointed in neat cement slurry and pointed in white or coloure cement to mathc the shade as specified and as directed. |
| 58 | M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18sqm but next 0.38 sqm in floors, over 15mm thick screed bed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured to match the shade of the tiles. Complete all as specified and directed. |
| 59 | M&L 10mm thick cement plaster 1:4 with water proofing compound @ 3% by weight of cement finish even and smooth surface.,complete all as specified and directed. Note- water proofing shall be measured and paid seperately. |
| 60 | Taking down cement plaster on brick/stone/concrete surface including wall tiling and hacking out joints hacking for key scrubbing down with water etc ,complete all as specified and directed. |
| 61 | M&L for 15mm thick rendering in CM 1:4 on brick or concrete surfaces finished even and smooth on wall with integral water proofing ,complete all as specified and directed.(Note: WPC shall be measured and paid seperately) complete all as specifed and directed. |
| 62 | M&L for 5mm thick rendering in ceiling in CM 1:4 on fair faces of concrete surface even and smooth complete all as specifed and directed. (without using extra cement ) etc. |
| 63 | M&L for 10mm thick in CM 1;6 rendering on brick or concrete surfaces finished even and smooth without using extra cement on wall complete all as specified and directed. |
| 64 | M&L rendering 20mm thick on surface of stone masonary surfaces in CM 1:6 and is to be finished even and fair without using extra cement complete all as specifed and dircted. |
| 65 | M&L for 20mm thick cement plaster in CM 1:4 on fair faces of stone masonary surfaces and finished the surface even and smooth (without using extra cement) with integral water proofing compound (Note: WPC shall be measured and paid seperately) on wall complete all as specifed and directed. |
| 66 | M&L 10mm thick screed bed with CM 1:3 with water proofing compound @ 3% by weight of cement finish even and smooth surface using without extra cement applied on padding concrete when concrete is still green (Note: water proofing shall be measured and paid seperately) complete all as specifed and directed. |
| 67 | M&L for preparation of newly plastered surfaces two coats of Distempering with 1st quality acrylic distemper (over a coat of alkali resistance primer) having VOC content less than 50 gms/litre, of approved manufacturer, if required shade and colour over 1-1.5 mm thick wall care putty on plastered surface by mechanical mean using suitable tools and plants complete, as per manufacturer's specification. Complete all as specifie and directed. |
| 68 | M&L for complete removal of existing treatment of walls plastered or unplastered, washing, rubbing down and two coats of Distempering with 1st quality acrylic distemper (over a coat of alkali resistant primer) having VOC content less than 50gms/litre, of approved manufacturer, of required shade of colour over 1mm to 1.5mm thick wall care putty on old wall surfaces by mechanical means using suitable tools and plants, as per manufacturer's specification. Complete all as specified and directed. |
| 69 | M&L for preparation of new decorated surfaces of walls plastered or unplastered applying Two or more coats of 100% Premium acrylic emulsion paint (Weather proof) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces by mechanical means using suitable tools and plants as per manufactures instruction etc complete all as specified and directed. |
| 70 | M&L for Complete removal of existing treatment and washing, rubbing down and stopping of distempering and painted surfaces applying two coats of premium acrylic smooth paint with silicone additives of required shade @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). Complete all as specified and directed. |
| 71 | M&L for preparation of new decorated surfaces of ceiling plastered or unplastered applying Two or more coats of 100% Premium acrylic emulsion paint (Weather proof) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces by mechanical means using suitable tools and plants over 1mm to 1.5mm thick wall care putty,Complete all as specified and directed. as per manufactures instruction. |
| 72 | M&L for preparation of old decorated surfaces of ceiling plastered or unplastered applying Two or more coats of 100% Premium acrylic emulsion paint (Weather proof) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces by mechanical means using suitable tools and plants over 1mm to 1.5mm thick wall care putty,Complete all as specified and directed. as per manufactures instruction. |
| 73 | S&F sheet glass 4.00mm thick Figured/frosted glass, pin head type & glazing with aluminium beeds in squares exc 0.5 sq.m in each pane. Complete all as specified and directed. |
| 74 | M&L for preparation of new steel/iron surfaces of any description having width/girth exceeding 10cm and applying two coats of synthetic enamel paint over red oxide primer for material and labour Complete all as specified and directed.. |
| 75 | Supply and laying of CPVC pipes 20 mm outer dia SDR 13.5 & Plain CPVC SDR 11 fittings on wall/ceiling or laying in floors ,Complete all as specified and directed. |
| 76 | Supply and laying of CPVC pipes 25 mm outer dia SDR 13.5 & Plain CPVC SDR 11 fittings on wall/ceiling or laying in floors ,Complete all as specified and directed. |
| 77 | M&L for spout of 50mm bore GI pipe and projection 450mm clear from outer wall in any length or description with rubber ring joints and fixed in sunken floor etc for drain out logging as in sunken floor etc or similar work complete all as specified and as directed. |
| 78 | Taking up or down steel tubing and connections of 15mm bore including cleaning for re-fixing or removal Complete all as specified and directed. |
| 79 | Taking up or down steel tubing & connections of 20mm bore ,including cleaning for re-fixing or removal Complete all as specified and directed. |
| 80 | Dismantling water tanks exc 500 & n exc 1000 litres., complete all as specified and directed. |
| 81 | S&F white coloured three layered Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I 1000 Ltrs Capacity |
| 82 | S&F in repairs Bib taps 15 mm bore, cast copper alloy with crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule fancy type , complete all as specified and directed. |
| 83 | S&F 15mm bore stop valves,cast copper alloy but fancy type,chromium plated with long shank and cup(concealed type),screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed. |
| 84 | S&F in repair angle stop, cast copper alloy screwed down high pressure with crutch or butter fly handle facny type, chromium plasted 15mm bore dia of pipe of minimum weight 320gms.Complete all as specified and directed. |
| 85 | S&F Ball valves 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe & fixed. (min. weight 20mm-210 gms) , complete all as specified and directed. |
| 86 | S&F in repair 15mm dia CP brass PVC connections 60cm long included check nut etc complete all as specifed and directed. |
| 87 | S&F 75mm dia UPVC (SWR) type B pipes single socketed in any length with rubber ring joints fixed in trenches or in floor all as , complete all as specified and directed. |
| 88 | S&F 110mm dia UPVC (SWR) type B pipes single socketed in any length with rubber ring joints fixed in trenches or in floor all as , complete all as specified and directed |
| 89 | S&F 110mm dia UPVC (SWR) type B pipes single socketed in any length with rubber ring joints fixed to walls , complete all as specified and directed. |
| 90 | S&F 75mm dia UPVC (SWR) type B pipes single socketed in any length with rubber ring joints fixed to walls , complete all as specified and directed. |
| 91 | S&F 110mm PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls , complete all as specified and directed. |
| 92 | S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal , complete all as specified and directed. |
| 93 | S&F UPVC (SWR) type B cowls of 75mm dia , complete all as specified and directed. |
| 94 | S&F UPVC (SWR) type B cowls of 110mm dia , complete all as specified and directed. |
| 95 | S&F 110mm PVC (SWR) vent cowl , complete all as specified and directed. |
| 96 | S&F 75mm dia UPVC (SWR) type B floor trap plain with grating with solvent cement etc complete all as specified. |
| 97 | M&L Concrete bed to 150mm dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested in PCC (1:3:6) type C2 , complete all as specified and directed. |
| 98 | M&L Concrete bed to 200mm dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested; in PCC (1:3:6) type C2 , complete all as specified and directed. |
| 99 | M&L Reinforced concrete pipes 150mm dia, class NP2, laid & jointed complete with collars , complete all as specified and directed. |
| 100 | M&L Reinforced concrete pipes 200mm dia, class NP2, laid & jointed complete with collars , complete all as specified and directed. |
| 101 | M&L for Cutting into existing manholes for connecting new drains 150mm dia, making good to pipe & rendering, cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, & reforming benching as required , complete all as specified and directed. |
| 102 | S&F in repair floor grating 100 mm dia with or without waste hole of stainless steel all as directed by the Engr-in-charge. |
| 103 | S&F UPVC (SWR) type B bends with oval access door 75mm dia , complete all as specified and directed. |
| 104 | S&F UPVC (SWR) type B bends with oval access door 110mm dia , complete all as specified and directed. |
| 105 | S&F 110mm UPVC (SWR) type B junction (single T) equal or unequal with access door , complete all as specified and directed. |
| 106 | S&F 75mm UPVC (SWR) type B junction (single T) equal or unequal with access door , complete all as specified and directed. |
| 107 | S&F in repairs Vitreous China squatting pan, `Orrisa' pattern, size 580 x440 mm, with integral foot rests (excluding flushing cistern & flush pipe). , complete all as specified and directed. |
| 108 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern & flush pipe) pedestal pan and trap including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc complete, plastic water closed seat black closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device all as specified and directed. |
| 109 | S&F Vitreous China Urinal, Half stall type, white including flush pipe and waste pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement: fixed automatic flushing cistern with bracket, flush pipe, grating and union for discharge pipe. (Exclusive of fixing supply pipe to flusing cistern, trap and waste pipe) with grating union discharge pipe etc complete all as specified. |
| 110 | S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level dual type of capacity 10 litr white with inlet ball valve float handle incl brackets ISI Marked incl 32mm PVC flush pipe complete all as specified and directed. |
| 111 | S&F chromium plated shower roses 125mm size with or without swivel joints any size including fixing to steel pipe or union all as specifed and directed. |
| 112 | S&F vitreous china wash basin (oval type) white round size 550x450/560x400 including waster chain and plug and porcelain stopper but including brackets 450mm PVC connection with brass screw inclduing waster coupling 32mm dia all as specifed and directed. |
| 113 | S&F health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified. |
| 114 | S&F 32mm High density polyethylene (HDPE) pipes of pressure rating 6kgf/Sq cm for urinal/wash basin/kitchen sink/flush tank. Complete all as specified and directed. |
| 115 | M&L forming contraction (dummy) joints 75mm deep x 10mm wide for plinth protection & similar work, filled with sealing compound Grade A in plinth protection , complete all as specified and directed. |
| 116 | Demolition of Brickwork or stone/boulder masonry, built in CM or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles |
| 117 | Demolition of Stone slabs & tiles of any description or thickness in floors, aprons etc. Laid in any type of mortar all as specified and directed. |
| 118 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 119 | Demolition of existing cement concrete (un reinforced) of any description & in any position not otherwise specifically provided for (unreinforced) |
| 120 | Demolition of any old unserviceable roof treatment of any description incl roof tiles/padding etc to expose the RCC slab of roof terracing, cleaning, washing & rubbing all as specifed and directed. |
| 121 | Demoliton of cement concrete (reinforced) of any description and in any postion not otherwise specifically provide for etc complete all as specified. |
| 122 | Dismnantling plain or corrugated steel sheeting any gauge thickness from Hanger doors complete all as specified and directed. |
| 123 | Dismantling Wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets.Complete all as specified and directed by Engr-in-Charge. |
| 124 | Demolition & breaking up drain pipes (Salt glazed ware/PVC/ AC or Reinforced concrete) set in CM 75/100/110 mm internal dia complete all as specified and directed. |
| 125 | Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM Internal dia of pipe 150 mm |
| 126 | Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM Internal dia of pipe 200 mm |
| 127 | M&L for levelling & ramming, rodding the floors including watering as required to level the surface of sub-base. Complete all as specified and directed by Engr-in-Charge. |
| 128 | S&F aluminium powder coated louvers concealed type for ventilator size 0.60x0.45/0.60x0.90 having arrangement of 4/6 blades fixed to aluminium frame complete all as specified. |
| 129 | S&F 600x450mm size bevelled edge mirror of selected quality glass,mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 130 | S&F two way bib cock with wall flange 15mm dia of minimum weight 450 to 480 gms complete all as specified and directed. |
| 131 | S&F in repair 15mm bore pillar taps facny type cast copper alloy with capstan heads, chormium plasted, screwed down high pressure with long screwed shanks and fly nuts screwed down for iron pipe (min weight 450gm etc) Complete all as specified and directed. |
| 132 | S&F of 15/20mm bore brass chromium plated wall mixer with bend of overhead shower including to steel pipe or union complete all as specifed and directed. |
| 133 | S&F rob hook with two arms with overall length 75mm fixed in CP bracket of size 70mmx49mm with wooden plugs with chromium plated brass screws and cup washer all as specified. Complete all as specified and directed. |
| 134 | Material and labour for single pipe in duct pipeline for waste water down take pipe fixing done with pipe supporting clamping system consisting of profile bracket + continous slotted C channel + U bolt R/M system -one waste water ipe 2 1/2\\" PVC (75mm) running vertically with wall distance 3\\" pipe support clamping shall be made of the following.(i) Profile bracket having wall distance 3\\" made of low carbon hot roll gauge corrected (HRGC) steel (IS 1079DD), material size 32mm x 3mm with ribs and notch Hot dip galvalnised + zn AI flake conated having salt spary test (test method- ASTM B-117-2019) result above 2000 hrs with SS304 hex flange bolt with serration 5/16x3/4 (A/F 13mm) as per DIN 6921 and SS304, Hex flange nut BSW 5/16X18X8X13 with serration as per DIN 6923. (ii) Continous slotted \\"C\\" channel with ribs to be used of size 10\\" made of low carbon hot roll gauge corrected (HRGE) steel (IS 1079 DD) are hot dip galvanized + Zn AI flake coated with material thickness of 3mm. (iii) U bolt R/M made of low carbon mild steel with rod diamerter 7mm approx ; Zn AI flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve with hex flange nut BSW 5/16X18X8X13 with serration set as pe DIN 6923-Zn AI flake coated. Hot dip galvanizing ; As per IS 2629 (1985)-610 GRAMS/Sqm (˃85 microns) Material Grade ; IS 1079 DD used as per MTC confirms to EN 10204 3.1. Material qty for one unit ; (a) Profile bracket wall distance 3°-2nos (b) Continous slotted C channel of size 10\\" 1 no (C) U bolt R/M fopr 2 1/2\\" PVC (75mm) pipe Dia -1 no (d) Just khilla 2 1/2\\" Zn coated -4nos. Fixing details: pipe cupport clamping unit to be fixed at every metre distance in the duct as specified in the Technical drawing : CEAG/AR/TD/08R. |
| 135 | Material and labour for single pipe in duct pipeline for waste water down take pipe fixing done with pipe supporting clamping system consisting of profile bracket + continous slotted C channel + U bolt R/M system -one waste water ipe 2 1/2\\" PVC (75mm) running vertically with wall distance 3\\" pipe support clamping shall be made of the following. (i) Profile bracket having wall distance 3\\" made of low carbon hot roll gauge corrected (HRGC) steel (IS 1079DD), material size 32mm x 3mm with ribs and notch Hot dip galvalnised + zn AI flake conated having salt spary test (test method- ASTM B-117-2019) result above 2000 hrs with SS304 hex flange bolt with serration 5/16x3/4 (A/F 13mm) as per DIN 6921 and SS304, Hex flange nut BSW 5/16X18X8X13 with serration as per DIN 6923. (ii) Continous slotted \\"C\\" channel with ribs to be used of size 10\\" made of low carbon hot roll gauge corrected (HRGE) steel (IS 1079 DD) are hot dip galvanized + Zn AI flake coated with material thickness of 3mm. (iii) U bolt R/M made of low carbon mild steel with rod diamerter 7mm approx ; Zn AI flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve with hex flange nut BSW 5/16X18X8X13 with serration set as pe DIN 6923-Zn AI flake coated.Hot dip galvanizing ; As per IS 2629 (1985)-610 GRAMS/Sqm (˃85 microns) Material Grade ; IS 1079 DD used as per MTC confirms to EN 10204 3.1. Material qty for one unit ; (a) Profile bracket wall distance 3°-2nos (b) Continous slotted C channel of size 10\\" 1 no (C) U bolt R/M fopr 2 1/2\\" PVC (75mm) pipe Dia -1 no (d) Just khilla 2 1/2\\" Zn coated -4nos. Fixing details: pipe cupport clamping unit to be fixed at every metre distance in the duct as specified in the Technical drawing : CEAG/AR/TD/08R. |
| 136 | M&L for water proofing treatment of sunken floor of WCs bathroom etc by applying of the following specification:- (i) cleaning of sunken floor surface with mechanical means i.e. wire brush/air blower etc and remove all loose/unsound material dirt/dust etc (ii) Applying cement slurry mixed with acrylic based polymer modified cementitious composite compound coating in the ratio 1:2:4 (one part of acrylic polymer: two part of water and four part of cement. (iii) first layer of cement slurry 0.444kg/sqm mixed with actylic based modified cementitious composite mixed with acrylic based modiifed cementtitous composite compound @ 0.111 litre/sqm and allow it to air dry for 4 hrs followed with water for 48 hours (v) spout pipe to be fefitted 50mm dia GI pipe of toal length 0.60mm, Note : joints of WC/Trap/soil waste shall be properly sealed withs ealing compound. Testing of all traps and joints and sunken slab shall be done as per IS-1742 before filling and tiling work as directed , complete all as specified and directed. |
| 137 | M&L for cutting shrubs, wild growth/vegetations and removal of plant growth by grubbing out shrubs/plants/any vegetation growth nexc 10cm girth including cutting of trunk portion protruding outside the wall/roof, digging out roots and application of chemical glyphosate solution (4% concerntration) as per manufactures instruction by injecting in stem of plants and roots as directed and removing complete vegetaion growth form walls including taking out roots fromm roof/stone/block masonary work and making good the distrubed surfaces with PCC 1:2:4 type B0 and disposing off the rubbish from the site outside MoD land for up to four storey building (incl scaffolding) complete all as specified and directed. |
| 138 | S&F FRP (fibre reinforced polymer cover & frame) HD 20mm graded rectangular of apporved size between 0.90x0.90m to 1.20 x1.20m and fixed over manhole after demolition of PCC coping & manhole cover & set in CM 1:4 including PCC benching in CM (1:2:4) and finishing smooth complete all as specified. |
| 139 | Note : In above Scope, Qty are considerd for Sewage disposal work also and for which contractor shall follow the following wherever required as per Scope of Work (i) Construciton of 01 No septic tank for 150 users of brick masonay as specified. (TD NO: CEAA/TD/79 SHEET 1/3 TO 3/3) |
| 140 | Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. |
| 141 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/ TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 142 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 143 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC conduit heavy duty ISI marked of white/ ivory colour including all accessories including all accessories concealed on wall/ ceiling etc, heavy duty, double locked system, ISI marked including sunk in anodized pressed steel box 1.60 mm thick, 60 mm deep for housing switch socket etc with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :- (for servent accn) |
| 144 | One light point controlled by one, one way switch 5 Amps |
| 145 | One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 146 | One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 147 | One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 148 | Ditto as per Srl item No 143.00 here in before but using 2.5 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH cable of multistranded PVC insulated unsheathed as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 149 | S & F for switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed. ISI Marked |
| 150 | S & F for switch Piano type single pole 15 amp, 230 Volts complete all as specified and directed. ISI Marked |
| 151 | S & F for ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete.ISI Marked |
| 152 | S & F for socket outlet 2/3 pin, 5 amp, 230 Volts complete all as specified and directed. ISI Marked |
| 153 | S & F for socket outlet 3/ 5 pin, 5/15 amp, 230 Volts complete all as specified and directed. ISI Marked |
| 154 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sq mm cable,one run of 4 sq mm cable and one run of PVC conduit will be measured as one unit |
| 155 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 156 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 157 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 158 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 159 | S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall/ Stone masonary wall for fan base compelte all as specified and directed. Note : Cost of suitable opening any type of wall for fixing exhaust fan and Making good disturbed surfaces is deemed to be included in overall rate quoted. |
| 160 | S & F for LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed. |
| 161 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 162 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail