| 1 | Supplying, laying, jointing and testing in replacement in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 120 Sq mm complete all as specified and directed. |
| 2 | All as per BOQ srl item No.1.00 here in above but of size 3.5 core 95 Sqmm complete all as specified and directed. |
| 3 | All as per BOQ srl item No.1.00 here in above but of size 3.5 core 70 Sqmm complete all as specified and directed. |
| 4 | All as per BOQ srl item No.1.00 here in above but of size 3.5 core 25 Sqmm complete all as specified and directed. |
| 5 | All as per BOQ srl item No.1.00 here in above but of size 4 core 16 Sqmm complete all as specified and directed. |
| 6 | All as per BOQ srl item No.1.00 here in above but of size 2 core 16 Sqmm complete all as specified and directed. |
| 7 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation laying of cables etc and getting out in soft loose soil complete all as specified and directed. |
| 8 | All as per BOQ srl Item No. 7.00 here-in- above but for depth exceeding 1.50 m and not exceeding 3.00 m complete all as specified and directed.. |
| 9 | Returning filling including spreading leveling watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and directed |
| 10 | Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soil complete all as specified and directed. |
| 11 | M&L for filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 08 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed.Note :- Thickness of sand cushioning after punning down i.e 18cm shall be measured for payment purpose only |
| 12 | M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed. |
| 13 | S&F GI tubing 80 mm bore light grade galvanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position including taking down existing one complete all as specified and directed. |
| 14 | All as per BOQ srl item No. 13.00 here in above but of size 50mm bore complete all as specified and directed. |
| 15 | All as per BOQ srl item No. 13.00 here in above but of size 40mm bore complete all as specified and directed. |
| 16 | Restretching properly and tightening ACSR conductor including rebinding after straining the single conductor on LT pole of any size replacing of jumpers if necessary all as directed by Engr-in-Charge. |
| 17 | S&F in replacement LT spacer 02 way FIX type made out of PVC material and suitable to work on 1100 volts fixed between 02 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed. |
| 18 | Make bore to road/cement path/hard standing for providing GI pipe 40/50/80 mm both end socketed for passing armoured cable incl making good the disturbed surface complete all as specified and directed. |
| 19 | Disconnecting the existing cable from panel/pole, preparing the end for jointing including all earth work and S & F end joint kit in replacement for 1.1 KV grade suitable for outdoor/indoor type terminal heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm complete all as specified and directed. |
| 20 | All as per BOQ srl item No.19.00 here-in- above but of size 16 to 50Sqmm complete all as specified and directed. |
| 21 | S&F joint kit in replacement kit for 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm complete all as specified and directed. |
| 22 | Taking down/out old Street light of any type / wattage and Supply and fixing LED street light fittings 90 watts, input 120 volts to 280 volts volts, life > 25000 Hrs, color temperature 5700K, initial efiicacy>= 100 lm/watt ,IP 66 , high pressure Die cast aluminium housing with weather proof gasket for lamp . the driver must be constant current type having power factor >0.90 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 5 KV high surges, necessary connection with multistranded copper conductor cable 3 core 1.0 sqmm for connection complete all as specified and directed . |
| 23 | All as per BOQ srl item No. 22.00 here-in-above but for 60 watt complete all as specified and directed. |
| 24 | S&F in replacement LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed. |
| 25 | S&F in replacement junction box thermoplastic polycarbonate enclosure, shock proof, IP65/IP66 (weather, rust, dust, water and vibration proof, outdoor type, internally embedded gasket with provision for all side cable entry through glands of size 250x200x100mm with 4Nos. aluminium bus bar of size 25x6mm, 8Nos. terminals with and including 01No. 10Amp MCB 10kA duly mounted fixed with MS clamps fabricated out of FI 40x3mm of required shape and size and feed at any location complete all as specified and as directed |
| 26 | S&F replacement LED garden light fitting with LED bulb upto 9 watt with clear acrylic cover in top section with IP 43 protection including all electrical connection with GI pipe light grade upto 90 cm including foundation complete all as directed by Engr in Charge. |
| 27 | S&F in repairs MCCB 63 Amp, 3 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 28 | S&F in repairs MCCB 100 Amp, 3 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 29 | S&F in repairs MCCB 125 Amp, 3 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 30 | S&F in repairs MCCB 160 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 31 | S&F in repairs MCCB 200 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 32 | S&F in repairs MCCB 250 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 33 | S&F in repairs MCCB 400 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. . |
| 34 | S&F in repairs MCCB 630 Amp, 4 pole 50 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 35 | S&F in replacement Bus Bar Chamber of size 45 x 45 x 30 cm suitable of 3 phase 433 Volts outdoor type and neutral made out of 3.15 mm thick M S Sheet with 100 Amps rated aluminium busbar (4 Nos ) PVC sleeves and coloured (Red,Yellow,Blue and Black) with locking arrangments and angle iron stand of size 40 x 40 x 6mm frame grouted in ground with PCC foundatiuon 1:2:4 type C1 with 20mm graded stone aggregate alongwith all necesary cable connections,lugs and cable gland including 2 coat of paint over a coat of red oxide primer all as directed. |
| 36 | All as per BOQ srl item No. 35.00 here- in-above but of size 60x60x45cm with 200Amps busbar complete all as specified and directed. |
| 37 | All as per BOQ srl item No. 35.00 here in above but of size 60x60x45cm with 400Amps busbar complete all as specified and directed. |
| 38 | S&F incl taking down LT feeder pillar panel weather proof outdoor type double door fabricated cout of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035( Siemens grey) shade with matt finish with seven tank pre treatment process.The panel shall be fabricated by CPRI approved manufacturer only.The panel shall be compartmentized designed totally enclosed ,dust & vermin proof,confirming to degree of protection IP-55,gasket between all adjacent units and beneath all covers shall be provided to render the joint dust proof. All doors and covers shall be provided with cylindrical panel locked .The panel shall be provided with aluminium bus bars,electrolytic grade of adequate rating or as specified below.The bus bars and interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB and black colour coding.The bus bar shall be supported on unbreakable,non hygroscopic,SMC insulated supports at sufficiently close interval to prevent bus bars sag and shall be housed in a dedicated compartment.The panel shall be prewired with FRLS PVC insulated copper conductors cables of suitable size properly tagged and secured..The panel shall be provided with digital Voltmeter/Ammeter with cast resign CTs & RYB LED indicating lamps at incoming.The panel shall be provided with heavy duty steel cable glands of adequate size for incoming & all outgoing cables..the panel shall be provided with manufacturer name plate,skull & bone danger notice board etc. the panel shall be provided with 04 numbers 50mmx50 mmx6mm thick angle iron supports . duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement.All MCCBs shall be provided with spreader links with phase seperator on both sided and suitable extended rotary handle for incoming MCCB complete all as specified and as directed.. the panel shall be provided with and including the following accessories : (a) Aluminium bus bar -600 Amps rating suitable for 3 phase 4 wire systemINCOMING:- (i) MCCB 4P 400 Amps 36 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection- 01 No(ii) Digital Ammeter 0-200 Amp-01 No(iii) Digital Voltmeter 0-500 Volt-01 No(iv) LED Indicating lamp R,Y, B-01 SetOUTGOING:-(i) MCCB 3P -100Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-06Nos (iii) MCCB 3P -63Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-01No |
| 39 | All as per BOQ srl item No-38.00 here in above but Panel with the following accessories are under. (a) Aluminium bus bar -400 Amps rating suitable for 3 phase 4 wire systemINCOMING:- (i) MCCB 4P 250 Amps 25 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection- 01 Nos(ii) Digital Ammeter 0-200 Amp-01 No(iii) Digital Voltmeter 0-500 Volt-01 No(iv) LED Indicating lamp R,Y, B-01 SetOUTGOING:-(i) MCCB 3P -160Amps 16 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-01Nos (ii) MCCB 3P -100 Amps 16 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-03Nos |
| 40 | All as per BOQ srl item No-38.00 here in above but Panel with the following accessories are under. (a) Aluminium bus bar -600 Amps rating suitable for 3 phase 4 wire systemINCOMING:- (i) MCCB 4P 400 Amps 36 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection- 01 No(ii) Digital Ammeter 0-200 Amp-01 No(iii) Digital Voltmeter 0-500 Volt-01 No(iv) LED Indicating lamp R,Y, B-01 SetOUTGOING:-(i) MCCB 3P -250Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-01Nos (ii) MCCB 3P -200Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-01No (iii) MCCB 3P -160Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-01Nos |
| 41 | All as per BOQ srl item No-38.00 here in above but Panel with the following accessories are under. (a) Aluminium bus bar -600 Amps rating suitable for 3 phase 4 wire systemINCOMING:- (i) MCCB 4P 400 Amps 36 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection- 01 No(ii) Digital Ammeter 0-200 Amp-01 No(iii) Digital Voltmeter 0-500 Volt-01 No(iv) LED Indicating lamp R,Y, B-01 SetOUTGOING:-(i) MCCB 3P -200Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-02Nos (ii) MCCB 3P -160Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-02No (iii) MCCB 3P -63Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-01Nos |
| 42 | All as per BOQ srl item No-38.00 here in above but Panel with the following accessories are under. (a) Aluminium bus bar -600 Amps rating suitable for 3 phase 4 wire systemINCOMING:- (i) MCCB 4P 400 Amps 36 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection- 01 No(ii) Digital Ammeter 0-200 Amp-01 No(iii) Digital Voltmeter 0-500 Volt-01 No(iv) LED Indicating lamp R,Y, B-01 setOUTGOING:-(i) MCCB 3P -200Amps 36 KA breaking capacity with fixed thermal & fixed magnetic over load protection -02 No(ii) MCCB 3P -160Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-02Nos (iii) MCCB 3P -100Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-03Nos Please Enable Macros to View BoQ information |
| 43 | All as per BOQ srl item No-38.00 here in above but Panel with the following accessories are under. (a) Aluminium bus bar -600 Amps rating suitable for 3 phase 4 wire systemINCOMING:- (i) MCCB 4P 400 Amps 36 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection- 01 No(ii) Digital Ammeter 0-200 Amp-01 No(iii) Digital Voltmeter 0-500 Volt-01 No(iv) LED Indicating lamp R,Y, B-01 setOUTGOING:-(i) MCCB 3P -200Amps 36 KA breaking capacity with fixed thermal & fixed magnetic over load protection -02 No(ii) MCCB 3P -160Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-02Nos (iii) MCCB 3P -100Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with-03Nos Please Enable Macros to View BoQ information |