| 1 | Excavation in foundations, trenches etc., in earth work , lift up to 1.50 metres stacking the excavated soil not more then 3 metres clear from the edge of excavation and then returning the stacked soil in 15 cm layers, when required in to plinths , sides of foundations etc., consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed within a lead of 20 metres in pick jumper work complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 2 | Providing and laying cement concrete 1:4:8 (1 cement:4sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth. complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 3 | Prov.and laying cement concrete 1:5:10 ( 1cement: 5sand:10graded stone aggregate 40mm nominal size) and curing complete excluding cost of centring and shuttering in: Foundation and Plinth complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 4 | Providing and laying cement concrete 1:1.5:3 (1cement:1.5 sand : 3graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work and re-inforcement for reinforced concrete work in : |
| 5 | Foundations, footings, bases of columns and the like and mass concrete complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 6 | Walls ( any thickness but not less than 0.1 m thickness) attached pillasters, buttresses, plinth and string courses, etc. from top of foundation level upto floor two level complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 7 | Suspended floor roofs landing & shelves & their supportsbalconies,beams, bressumers & cantilevers upto floor two level complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 8 | Providing tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 9 | Providing and laying cement concrete 1:2:4(1cement:2sand:4graded stone agg. 20mm nominal size) excluding cost of form work and reinforcement for reinforced concrete work in foundation and plinth complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 10 | Walls ( any thickness but not less than 0.1 m thickness) attached pillasters, buttresses, plinth and string courses, etc. from top of foundation level upto floor two level complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 11 | Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish I/c centring , shuttering , strutting and proping etc.with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4mtrs. and removal of the same for insitu- reinforced concrete & plain concrete work in :- |
| 12 | Foundations, footings, basis of columns etc. and mass concrete complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 13 | Vertical surfaces such as walls (any thickness& shape), partitions and the like including attached pillasters, buttress,plinth and string courses and the like complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 14 | Beams, Cantilevers, girders and lintels : Sides and soffits of beams, beam haunchings, cantilevers, girders , bressumers and lintels not exceeding 1 metre in depth complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 15 | In Column, pillars, posts and struts Square rectangular or polygonal in plain complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 16 | In flat surfaces such as suspended floor roofs, bottom of beams, landing, softs and like floor etc.upto 200 mm complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 17 | Edges of slab and breaks in floors and walls under 20cm wide complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 18 | Brick work using common burnt clay building bricks in Superstructure above plinth level 1st class bricks cement mortar 1:6 (1cement:6 sand) with in complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 19 | Half brick work using common burnt clay buildings bricks in cement mortar 1:4(1cement:4sand) 1st class bricks in super structure with in all leads and lifts. |
| 20 | Providing wood work in frames of doors, wndows, clerestory windows and other frames wrouhgt, frramed and fixed in position in 2nd class Deodar wood within all leads and lifts as per direction & satisfaction of Engineer-in-charge. |
| 21 | 6mm thick cement plaster to ceiling in CM 1:3 ( 1Cement :3 Sand) with in complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 22 | 15 mm thick cement plaster in single coat on rough side of brick/concrete stone walls for interior plastering up to floor two levels including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortar 1:4 (1 cement:4 sand) with in all leads and lifts |
| 23 | Providing and fixing panelled glazed or panelled and glazed shutters for doors, windows and clerestory windows i/c bright finished black enammeled iron hinges with necessary screws: 2nd class deodar wood 40mm thick including entire carriage of material as per satisfaction of Engineer-in-charge. |
| 24 | Providing & fixing wire gauged shutters for doors, windows and cleristory windows including black enamelled iron but hinges with necessary screws. 40 mm thick 2nd. Class deodar wood complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 25 | Boulder filling behind retaining wall under floor with in complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 26 | Precast terrazzo tiles hydraulic compressed 20 mm thick with marble chips of specified sizes laid in floors, treads of steps and landings on a bed of 25 mm average thickness of cement mortar 1:6 (1 cement :6 sand) jointed with neat cement slurry mixed with pigment to match the shade of tiles (wherever required) incliding rubbing and polishing complete with tiles of following shades complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 27 | Providing and fixing M.S. grills of require pattern in wooden frames of windows etc. with M.S. Flats, square or round bars with round headed bolts and nuts or by screws with in complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 28 | Applying priming coat on new wood and wood based surfaces with ready mixed paint and brushing to give an even shade including cleaning of all dirt,dust and other foreign matter with in complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 29 | Applying priming coat over new steel & other metal surfaces after & including preparing the surface by thoroughly cleaning oil grease dirt and other foreign matter and scoured with wire brushes fine steel wool scrapers and sand paper complete complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 30 | Painting two coats (excluding priming coat) on new wood and wood based surfaces,with enamel paint to give an even shade including cleaningthe surface of dirt ,dust and other foreign matters sand papering and stopping with readymade paint other than white with in all leads and lifts. Ready mixed paint other than white complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 31 | Painting two costs (excluding priming cost on new steel and other metal surfaces eith enamel paint brushin to give an even shade including cleaning the surface of all dirt,dust and other foregin matters : Ready mixed paint other than white complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 32 | Distempering (two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on undecorated wall surfaces to give an even shade over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brushing the surface free from mortar droppings and other foreign matter and also including preparing the surface even and sand papered smooth. Priming coat with distemper primer complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 33 | Providing and fixing anodized aluminium sliding door bolt anodized transparent or dyed to required colour and shade with bolts and nuts and screw complete with in all leads and lift |
| 34 | 300x16 mm |
| 35 | Providing and fixing aluminium tower bolts(barrel type)anodized transparent or dyed to required shade and colour with screws etc. in complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 36 | 200x10mm. |
| 37 | 150x10 mm |
| 38 | Providing and fixing aluminium handles anodized transparent or dyed to required colour or shade with necessary screws etc. complete with in all leads and lifts |
| 39 | 125 mm |
| 40 | 100 mm |
| 41 | Providing under layer for plinth protection of 75mm thick (unconsolidated) bed dry brick/stone aggregated 40mm nominal size with rammed and consolidated and grouted with fine sand including preparation of ground complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 42 | Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement: 3sand: 6 graded stone aggregate 20mm nominal size). complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 43 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required Group-B complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 44 | Wiring for Circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 45 | 2x1.5 Sq. mm. |
| 46 | 2x4.00 Sq. mm. |
| 47 | 2x6.00 Sq. mm. |
| 48 | Supplying and fixing following rating Piano-type switch /socket on the existing switch box / cover including connections etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 49 | S.P. 15/16 Amps one way switch, porcelain base/ piano type |
| 50 | S.P 15/16 Amps socket outlet, porcelain base/ piano type. |
| 51 | Bell push , piano type. |
| 52 | Supplying & fixing metal box of following sizes (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 53 | 180mm.x100mm.x60mm. deep |
| 54 | 250mm.x300mm.x100mm. deep |
| 55 | Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCBDB complete with connections etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 56 | Double Pole Cat-A |
| 57 | Supplying and erectionof6 amps. to32amps. rating,10KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of followingpoles in theexistingMCBDBcomplete with connections etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 58 | Single pole Cat-A |
| 59 | Supplying and fixing following rating, double pole (single phase & neutral )240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 miliampers in theexisting MCB DB complete with connections, testing and commissioning etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 60 | 63 Amps. Cat-A. |
| 61 | Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate blanking plate, cable, identification labels interconnections,phosphatized and powder painted, including earthing etc. as required:- |
| 62 | Single door-12 way |
| 63 | Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with2-way, 5/6amps. piano type switch and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge Group - A |
| 64 | Supplying and fixing ceiling rose on the existing junction box / wooden block including connections etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 65 | Supplying and fixing bakelite batten/angle holder including connections etc. as required:- |
| 66 | Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 67 | Exhaust Fan, Light duty, (Domestic) 300 mm sweep |
| 68 | Providing and fixing Cera/Hindware make double symphonic “P” or “S” trap WC pan (two piece ) complete in all respect. With built in cistern 10 litr capacity of required shade (CRUSE 2018) WC-1 complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 69 | Providing and fixing Cera/Hindware make double symphonic “P” or “S” trap WC pan (indian type ) complete in all respect. WC-2 complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 70 | Providing and fixing 10 litr vitreous china high level flushing cistern of Hindware/ Cera make complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 71 | Providin and fixing plastic seat cover solid type ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge. |
| 72 | Providing and fixing vitreous china 55x40cm flat back wash basin ( White colour) with MS brackets duly painted (cornet-1008 of Cera/Hindware make.) complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 73 | Providing and fixing PVC waste pipe 32mm nominal dia for wash basin and sink ISI mark of reputed make complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 74 | Providing and fixing M.I. Union for wash basin or sink complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 75 | Providing and fixing 450x600mm bevelled edge mirror of reputed make mounted on AC sheet and fixed with brass screws with complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 76 | Providing chromium plated brass soap dish with brass bracket of reputed make complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 77 | Providing and fixing 15mm angle valve ISI (Heavy duty) ISI mark of reputed make complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 78 | Providing and fixing PVC connection 15mm of superior quality complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 79 | Providing and fixing 100mm dia CP grating for floor traps of superior quality complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 80 | Providing & fixing CP 15mm dia short body bib tap ISI mark of reputed make complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 81 | Providing and fixing spray flushing jet ISI mark of reputed make complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 82 | Providing and fixing GMS tube (heavy class) ISI mark of reputed make complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts..including GI fitting of following dia:- |
| 83 | 15mm dia |
| 84 | Providing and fixing PVC pipe ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge. |
| 85 | 100 mm dia |
| 86 | 75 mm dia |
| 87 | Providing and fixing PVC door bend ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge. |
| 88 | a) Door bend |
| 89 | Providing and fixing PVC Plain bend ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge. |
| 90 | a) Plain bend 100 mm dia |
| 91 | a) Plain bend 75 mm dia |
| 92 | Providing and fixing PVC water tank 1000 ltr capacity including all necessary fitting for water storage tank complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 93 | Prov .and fixing C.I. Sluice valve (with hand wheel) as per IS;780 Class upto 300 mm dia (including brass spindle and as per IS:2906 class II for diameters more than 300 mm complete with bolts, nuts, rubber insertion etc,(The tail pieces if required shall be measured and paid for separately) |
| 94 | 350 mm diameter for inlet, outlet and scour complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 95 | Providing 200mm wide cast iron rungs with chequered or ribbed non slip surface including fixing in manholes with 200x200x100mm cement concrete 1:3:6 (1 cement :3 sand :6graded stone aggregate 20mm nominal size.) complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 96 | Providing , laying,jointing and testing , fixing in trenches ( by way of circumfrential Butt welded of MSERW pipe of following dia meters confirming to ISO 3183-2007, , pipe grade L-290 or X-42 having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, provinding and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). |
| 97 | MSERW Pipe L-290 Grade-A 350 mm dia. 4.8 mm thickness (Rising Main) |
| 98 | MSERW Pipe L-290 Grade-A 150 mm dia. 4.8 mm thickness (Rising Main) |
| 99 | Demolishing reinforcement cement concrete including equivalent design mix manually / by mechnical means including stacking of steel bars & disposal of unserviceable materials / disposal of materials with in 50 meters complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. Please Enable Macros to View BoQ information |