| 1 | CIVIL WORKSConstruction of Indoor HallExcavation in Soil (any type) using Hydraulic Excavator OK 90 with Hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all liftes and combined lead upto 30 m. Earth filling under floors with surplus ordinary soil or siol containg gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers incluing ramming, watering and consolidating lead upto 30 meters (34+63=97+5.35%=102.19) |
| 2 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 3 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 4 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 5 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 6 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 7 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 8 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 9 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 10 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 11 | Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded |
| 12 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 13 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure |
| 14 | 12.5 mm thick cement plaster 1:5 |
| 15 | 20mm thick cement plaster 1:5 in two coat work |
| 16 | 12.5 mm thick cement plaster 1:4 |
| 17 | 20 mm thick cement plaster 1:4 in two coat work |
| 18 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4.0 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. |
| 19 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend |
| 20 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 21 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers including ramming, watering and consolidated upto all lead. |
| 22 | Earth filling under floors with surplus soil containing more than 40% gravel or kankar excavated from foundation & taken only from outside the building plinth in 15 cm layers including ramming watering and consolidation lead upto 30 metres |
| 23 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100mm sand filling using mechanical mixer for mixing of material |
| 24 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 25 | Extra labour for projected nosing of stair case of any shape and design. |
| 26 | Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of Engineer-in-charge. |
| 27 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate |
| 28 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing3.95 kg per meter. |
| 29 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1 (1999)) Commercial with elm or gurjan facing on both Sides with laminated core and lipped edges:- 35mm thick |
| 30 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm |
| 31 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles, Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 32 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash- welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) |
| 33 | Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. |
| 34 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqmexceeding 0.4 sqm of area |
| 35 | Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm X 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes instead of glazing clips and metal slash putty in steel doors , windows & Ventilators complete in all respect |
| 36 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 37 | Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm (+ 0.05 %) thick |
| 38 | G.I. Sheet gutters 0.80mm thick semicircluar 15cm diametre including fixing with clamps and making connections with rain water pipes. |
| 39 | Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete |
| 40 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 41 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats on old distempered work when shade is changed |
| 42 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 43 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 44 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 45 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 46 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 47 | Finishing walls with cement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade |
| 48 | Badminton Court & Table Tennis Providing and fixing of PU Flooring for Badminton Court:PRODUCT INFORMATION: Conipur Hg Eco System 7+2mm for Badminton Court. The Conipur Hg Eco System 7+2mm System is designed especially for indoor sports club and multipurpose gyms. The granular rubber mat spormat and the self leveling polyurethane resin based finish make the surface elastic and resistant and ideal for badminton, which may be played on a synthetic court or in schools. The system reduces the risk of slipping, reduce muscle fatigue and ensures better ball bounce. The Conipur Hg Eco System technically performance over the years. The Conipur Hg Eco System 7+2mm also ensure excellent acoustic comfort as confirmed by specific tests and is therefore also ideal for heated flooring. PU Flooring System 7+2mm for Badminton COURT Conipur Hg Eco System 7+2 mm IF, FIBA, FIVB, BWF APPROVED |
| 49 | Providing and fixing of Flooring for Table Tennis:Providing & laying multilayer Sports synthetic sports surface of 4. 5mm thickness and comprising of 100% pure PVC Wear Layer sport flooring sheet, insuring optimal adhesion on its surface through its embossing. Special foam layers to absorb impacts from jumps and protects the joints and muscles. Excellent power return and optimal slip coefficient which offers natural grip to avoid falls and accidents. Glass fiber reinforced middle layer to provide dimensional stability to the product. It should provide high wear resistance up to 27% and easy maintenance to Sports and made with solvent free technology in any colour complete in all respect & as per specifications and as desired by Engineer-in-Charge. |
| 50 | ELECTRICAL WORKSRECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring light point |
| 51 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (Un-sheathed) |
| 52 | Overall size 2.5sq.mm (Un-sheathed) |
| 53 | XLPE INSULATED LT CABLES: XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 16sq.mm (2Core) Un-armoured(Loose) |
| 54 | Overall size 25sq.mm (3½ Core) Un-armoured (Loose) |
| 55 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD GeneralSpecifications:- Heavy Gauge PVC Conduit Pipe 25mm dia.(Flushed) |
| 56 | MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size ofthimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 57 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 58 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color- coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles andbonding to existing earth etc:- TP&N Horizontal Double Door DistributionBoard 4 way each |
| 59 | SHEET METAL IRON CLADCHANGEOVER SWITCHES: Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications: IC Four Pole Changeover Switch 200amp.,415volts |
| 60 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double Walled Corrugated HDPE Pipe 50/38mm (Outer/ Inner dia.) |
| 61 | LT PANELS:Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panelenclosure (dust, vermin and interchangeable modules with facilites for extensions or reductionas per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel.The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimumdepth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc.The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fullycompartmentalized type i.e. bus bar chamber as well as the cable chamber should be totallyisolated from the feeder chamber. Where there crossing of the wire or bus links. It should haveproper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishingtreatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work. |
| 62 | Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustablecable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering:-The panel shall be completed with digital metering unit (with selector switches,voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc.Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding thecost of MCCB's) as per following:- LT Panel enclosure having space for 1No. Incomer MCCB 200Amp. and 4Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 1000 x 300mm)MCCB's (FOR PANELS & SHEET ENCLOSURE): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-MCCB Four Pole 63/80/100amp., 415volts,≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 63 | MCCB Four Pole 200amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 64 | Supply and erection of Copper Chemical Earthing 3 meter long earthing rod typically has a copper-bonded steel rod with a minimum 250-micron copper coating, a diameter ranging from 14 mm to 50 mm or more, and a high tensile strength of around 90,000 psi. For installation, it is placed in an augured hole, surrounded by earth enhancing compound, and often interconnected with other electrodes using a 25x2mm copper strip or 8mm solid copper conductor, buried at least 500 mm deep. Complete in all respect as per satisfaction of engineer in charge at site. |
| 65 | Supply and Erection of Heavy Duty Exhaust Fan Suitable size 12” (300mm) including Louver shutter, connection & testing complete in all respects as desired by the Engineer in charge of work at site. Exhaust Fan, Blade Sweep : 300 mm (12”), Type of motor : Permanent capacitor induction motor, C75 Rated Voltage : 230 volts, 50 Hz, AC. single Phase, Test voltage : 230 volts, 50 Hz, .AC. I Phase, Frequency : 50 Hz., Capacitor rating : 1.0 F, 400V, 50 Hz, AC., Rated watts at full (load) speed & at 230V. : 27 watts., Current in amps at full speed & at 230 V. : 0.12 Amps., Power factor : 0.9 min., Rated full speed & at 230 V : 1310 rpm., Rated air delivery at 230 V : 800 M3/hr, Rated Service value : 30 m3/hr/watt, No. of blades leaves : Five, Type of blade leaf : Plastic (PP), No of running positions : One position, Class of Insulation : Class “E”, Type of bearings : Oil impregnated self aligned bush bearings. |
| 66 | Supply and Erection of Wall fan Suitable size 16\\" (400mm) including connection & testing. Complete in all respects as desired by the Engineer in charge of work at site. BASIC FEATURES - Sweep size : 400 mm, No. of blades : 3, Adjustable upward and downward tilt mechanism: Yes, Guard : 120 Spokes, Motor speeds (No.) : 3, Motor type : Normal Speed, Oscillation : Yes, Oscillation degree : 60˚, Remote control option : No, Reversible blades : Yes, Switch : Yes, DESIGN FEATURES - Blade design : Aerodynamically designed & Blanced Blade, Blade finish : Transparent, Body colour : White, Finish : Glossy, Pull cord : Yes, DIMENSIONS AND WEIGHT - Packaging dimensions WxHxD : 46.8 cm x 20 cm x 46.8 cm, Weight : 3.3 kg, PERFORMANCE FEATURES - Rated Speed : 1350 revolution per minute, Air delivery : 72 m³/min, Noise level : 63.2 dB, POWER FEATURES - Power Consumption : 50 W, Rated frequency : 50 Hz, Rated Voltage : 230 V, SAFETY FEATURES - Motor protection through thermal overload protection device : Yes. |
| 67 | SITC of Single Panel Glare free LED Racket Ray designed with uniform light distribution with low power consumption along with SMD based 5700K CCT, CRI >80, IP42 Protection, Aluminium Housing with Honeycomb lens, IK07, 150W Power consumption, Input Voltage/Current : 190 240V, PF >0.9, Beam angle 120°, Working Temperature : -10° ~ +60°, Dimension : L1200 x W180 x H50mm. complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Tubelight and drive should be tested by NABL accredited LAB. |
| 68 | Supply and Erection of 100 Watt LED Flood Light fitting (including LED driver) with pressure die cast aluminium housing with control gear (IP 66 protection),THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the Lighting Fixture manufacturer should have inhouse NABL accredited LAB. Please Enable Macros to View BoQ information |