| 1 | M&L for Surface dressing n exc 15 cm deep in soft/loose soil and geting out complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 3 | M&L for Sand filling under floors or in foundations including watering and consolidation as specified or directed by Engr In Charge. |
| 4 | M&L for Cement concrete (1:4:8) using 40 mm graded stone aggregate as in foundation filling and mass concrete as specified or directed by Engr in Charge . |
| 5 | M&L for TMT Bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed. |
| 6 | M&L for TMT Bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required including cranking, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed. |
| 7 | M&L for use and waste for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; roof beam and similar work; vertical or to batter complete all as specified and directed. |
| 8 | M&L for use and waste for Formwork to sides of pillars,posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 9 | M&L for use and waste for form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams for rough finished surfaces of concrete flat complete all as specified and directed |
| 10 | M&L for RCC (Design mix) M-30 (20 mm graded aggregate) foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete as specified or directed by Engr in Charge . |
| 11 | M&L for RCC (Design mix) M-30 (20 mm graded aggregate) Columns, pillars, piers, posts and struts etc., as specified or directed by Engr in Charge . |
| 12 | M&L for RCC (Design mix) M-30 (20mm aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span as specified and directed by Engr In Charge . |
| 13 | M&L for RCC (Design mix) M-30 (20 mm graded aggregate) Chajjas etc., as specified or directed by Engr in Charge . |
| 14 | M&L for use and waste for form work to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete flat complete all as specified and directed. |
| 15 | M&L for use and waste for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide including edges for rough finished surfaces of concrete flat complete all as specified and directed. |
| 16 | M&L for brickwork with fly-ash bricks (with old size bricks), straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed |
| 17 | M&L for Rendering 15mm thick in cement mortar (1:4) on EXTERNAL fair faces or Brick walls or on concrete surfaces plastered surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 18 | M&L for Rendering 15mm thick in cement mortar (1:6) on INTERNAL fair faces or Brick walls or on concrete surfaces plastered surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 19 | M & L for hardcore of gauge n.exc 63mm deposited spread and leveled in layer not exc 150 mm thick water, rammed to a true surfaces as floor complete all as specified and as directed. |
| 20 | M & L for PCC (1:3:6) type C2 with 40 mm graded aggregate as in foundation filling and mass concrete in column & wall foundation, complete all as specified and as directed. |
| 21 | M & L for PCC (1:2:4) type B2 100 mm thick (using 40mm graded aggregate) as in floor finished the concrete surface even and smooth W/O using extra cement complete all as specified and as directed. |
| 22 | M & L for 40 mm thick cement concrete type-B0 1:2:4 (Using 12.5mm graded stone aggregate) as in floor finished the concrete surface even and smooth with using extra cement complete all as specified and as directed. |
| 23 | M&L for Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade A. thickness of concrete slab in 250 mm complete all as specified and as directed. |
| 24 | Supply and Installation of Vinyl floor of Enlio 4.5mm Blue PVC sports floor mat with standard Doubles Badminton Court 2 layer marking and game line marking complete all as specified and directed by Engr- in -Charge. |
| 25 | S&F for Steel work in tubular trusses in roof trusses (framed), trussed, posts, purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and directed. |
| 26 | S&F Framed work as Fe 410 W(Gde-E-250)quality A (inverted Hollow Circular U shape Pipe jointed with bend in ground)in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled forfixing of steel sheeting or other covering,Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete complete all as specified and directed. |
| 27 | M&L for plates (plain or chequred) channels, square cut or notched with riveted or welded attachments complete all as specified and directed. |
| 28 | M&L16 to 20mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm and 30cm long all as specified. |
| 29 | S&F for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed. |
| 30 | S&F for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed. |
| 31 | M&L for new steel and iron surfaces apply two coats of synthetic enamel paint over one coat of red oxide primer of any description, exc 10cm in width or girth, not otherwise described complete all as specified and directed. |
| 32 | M&L for Finishing walls with Acrylic Smooth exterior paint of required shade: New work (two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) all as specified and directed. |
| 33 | M&L for two coat of oil emulsion distemper over a coat of primer on internal surface of new wall,complete all as specified and directed. |
| 34 | M&L for 100mm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in plinth protection finishing surface even and fair complete all as specified and directed. |
| 35 | M&L for forming construction 100 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’complete all as specified and directed. |
| 36 | M & L for PCC (1:2:4) type B-1 40mm thick as in floors finished in flooring/ hard standing finished even complete all as specified and directed. |
| 37 | M&L for providing chequered cement concrete tiles 20cmx 20cm x25mm thick with mixture of white and grey cement in equal proportion and no pigment over 20mm thick screed bed or bedding layer of mortar in CM (1:6) to receive floor finishes complete all as specified and directed. |
| 38 | Returning filling including spreading, levelling, watering & well ramming in layers n exc. 25 cm soft and loose soil complete all as specified and directed. |
| 39 | Removing excavated material nexc 50 m but n exc 1.5 m & depositing where directed at a level n exc. 1.50m above the starting point complete all as specified and directed. |
| 40 | S&F for anodised aluminium powder Coating minimum thickness of powder coating 50 micron to frame for doors, windows, ventilators, Almarah, cup board and partation walls with one or more rebates including joining cleat for fixing. rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed. Note : powder coat should be match existing colours. |
| 41 | S&F for Anodised aluminium powder coating 50mm thick micron door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. |
| 42 | S&F for Anodised aluminium powder coating 50mm micron window and ventilator shutters, cup board shutter for sliding type etc fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified. |
| 43 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge |
| 44 | S&F 4.8mm thick ordinary quality sheet glass/frosted glass and glazing with oil putty in square exc. 0.5 Sqm in each pane complete all as directed. |
| 45 | S&F 4mm thick Figured glass pin headed type and glazing with oil putty in square exc 0.5 Sqm in each pane. |
| 46 | S&F stainless steel wire cloth, 0.65mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples complete all as directed. |
| 47 | S&F butt hinges, medium weight, cold rolled mild steel, 125mm complete all specified. |
| 48 | S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded setion or cast aluminium alloy and fixed 250 mm long complete all as specified and directed. |
| 49 | S&F anodised aluminium barrel tower bolt extruded section 150 mm size complete all as specified and directed. |
| 50 | S&F 150mm floor door stopper of aluminium alloy body and tongue anodised, with hard drawn steel spring fixed in door complete all as specified and directed. |
| 51 | S&F Extuded aluminium alloy handles, fabricated type anodised section 150 mm size complete all as specified and directed. |
| 52 | S&F for Brass 4 levers Mortice lock, vertical type, size 100 mm all as specified and directed. |
| 53 | S&F for movable badminton posts(set of 2) (weight of posts 100 kgs of pair, adjustable rachid with Badminton Net fine quality spray PU paint complete all as specified and directed by Engr- in -Charge. |
| 54 | M & L for concealed type point wiring with 2.5 sqmm (Nominal Area) FRLSH PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC conduit medium duty (ISI marked) not less than 25 mm dia with accessories such as bends, cross, elbow, tees etc. of suitable size including continuous earth wire FRLSH PVC insulated unsheathed 2.5 Sq mm(nominal area) copper multi-stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly and making good disturbed surfaces complete all as specified and as directed. |
| 55 | All as per item No 54 above but for one three pin socket outlet, 5 amp on independent board with 1.5 sqmm PVC insulated (FRLSH) unsheathed copper cable multistranded conductor 1100 volts grade complete all as specified and directed. |
| 56 | Supply and fixing LED highway lights 200 Watt with efficiency upto 110 LPW with IP 66 protection, glare free , front toughned glass with high lumens suitable for indoor sports court complete as per site requirements and all as specified and as directed |
| 57 | Supply and fixing 600mm sweep industrial type wall mounted air circulator fans complete including fittings and fixtures complete as per site requirements and all as specified and as directed |
| 58 | Supply and fix LED street light 70W IP 65 for Bldg Security light with minimum system efficacy 100 lumen/watt including all necessary bracket and fittings complete all as specified and as directed. |
| 59 | M & L Ceiling rose, surface type polycarbonate/ PVC three terminals, for tube light, conforming to IS complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 60 | M & L Ceiling rose, surface type polycarbonate/ PVC three terminals, for tube light, conforming to IS complete all as specified and as directed. Please Enable Macros to View BoQ information |