| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm. |
| 2 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 3 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead of area of 3 sqm. and below. |
| 4 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge. 1:3:6 or richer mix (i/c equivalent design mix). |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 7 | 12mm Cement plaster of mix 1 : 6 (1 cement : 6 coarse sand). |
| 8 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead With cement mortar 1:4 (1 cement : 4 coarse sand). |
| 9 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 10 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete in all colours, shades, except White, Ivory, Fume Red Brown. |
| 11 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigmentsetc. complete size of tile 600x600 mm. |
| 12 | Providing and fixing of PVC wall panelling of superior quality of make like wall face or equivalent (0'-10\\" x 10'-0\\" @ 3.4 Kg/E) with necessary fittings / accessories (Make approved by E.I.C) complete job. |
| 13 | Providing and fixing of Zebra blinds of approved colour made from 100% polyester yarn coated with fade resistant polymer to ensure complete opaquely with zero light transmittance having width of 280cm and weight of 148g/sqm +5% and fabric repeat size having solid 13.5cm +5% and mesh 9cm+5% conforming to relevant IS parameters (Hunter Douglas / Johnson / Hillarys / Vista / marvel) including all fixtures and fittings complete in all respect as per design and make approved by engineer in charge (Complete job). |
| 14 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 15 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick. |
| 16 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 17 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work. |
| 18 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work. |
| 19 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. W.C. pan with ISI marked white solid plastic seat and lid. |
| 20 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 21 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931. |
| 22 | Providing and fixing uplasticized PVC connection pipe with brass unions 45 cm length 15 mm nominal bore. |
| 23 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete. Flexible pipe 32 mm dia. |
| 24 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31mm of 79 mm length and 62 mm breadth weighing not less than 45gms. |
| 25 | Providing and fixing PTMT grating of approved quality and colour. Circular type. 125 mm nominal dia with 25mm waste hole. |
| 26 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931. |
| 27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 15mm nominal outer dia pipes. |
| 28 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 20mm nominal outer dia pipes. |
| 29 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 30 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265mm sizes respectively. |
| 31 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre. |
| 32 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 75 mm diametre. |
| 33 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (4 kg/Sqcm pressure) Coupler 75 mm. |
| 34 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler 110 mm. |
| 35 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door 75x75x75 mm. |
| 36 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm. |
| 37 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. 25 mm nominal bore. |
| 38 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 39 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. |
| 40 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 41 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 42 | Renewing glass panes, with putty and nails wherever necessary including raking out old putty. Float glass panes of thickness 5.0 mm(weight not less than 12.5 kg/sqm). |
| 43 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately) For fixed portion Powder coated aluminum (minimum thickness of powder coated 50 microns). |
| 44 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately). For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminum (minimum thickness of powder coated 50 microns). |
| 45 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge. Pre-laminated particle board with decorative lamination on both sides. |
| 46 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item). With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm). |
| 47 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm. |
| 48 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 150x10 mm. |
| 49 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete. 250x16 mm. |
| 50 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Single rubber stopper. |
| 51 | Engaging tractor with trolley for disposal of mulba, unhygenic material away from site as per direction of Engineer-in-charge. |
| 52 | Engaging labour as per requirement at site. |
| 53 | Engaging Carpenter as per requirement of site. |
| 54 | Engaging Plumber as per requirement of site. |
| 55 | Supplying, Installation, Testing and commissioning of 1.5 Ton Invertors Type Split AC (Copper) Cold type of minimum capacity, following specification as detailed below :-1/ Should be of Invertors Type. 2/ Coiling capacity, (In tr) : 1.5. 3/ BEE Star rating 3.4/ Maximum local temperature 52-C.5/ Rated coiling capacity (BTL/ Hr) : 19000 or above.6/ Condensing coil : 100% copper with grooved copper tubes.7/ Electrical input, 220 V + 30/50 Hz / Single Phase.8/ Noise level (indoor unit) : = close to 35 DB.9/ Compressor type : Rotary or any other suitable technology.10/ Refrigerant type : R-32.11/ Ant-Corrosive coating for the outdoor unit Bule Fin / Gold Fin equivalent.12/ Compressor warranty : 10 Years.13/ PCB warranty : 5 Years14/ Total system warranty : 1 Year.15/ Minimum noise level of the indoor unit should be mound 28 DB (A).16/ Should have air filtering mechanism for removing dust.17/ Supplier has to include brochure of the quoted model each unit must provide coiling and dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job include repairs. |
| 56 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required (Group-B) |
| 57 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required. |
| 58 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 59 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 60 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 61 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 62 | Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. |
| 63 | 2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire |
| 64 | 2 x 2.5 sq mm + 1 x 2.5 sq. mm earth wire |
| 65 | 2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
| 66 | 2 x 6 sq. mm + 1 x 6 sqmm earth wire |
| 67 | 4 x 10 sq. mm + 2 x 6 sq. mm earth wire |
| 68 | 4 x 16 sq. mm + 2 x 6 sq. mm earth wire |
| 69 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. |
| 70 | 1 x 1.5 sq. mm |
| 71 | Supplying and fixing of ceiling fan of followingsweep with 2.25 mfd condenser and 1'-6\\" down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. (As approved site in-charge) |
| 72 | 1200 mm sweep (3 Star) |
| 73 | Supplying and fixing of 400 mm sweep wall mounting fan (oscillating type) on wall with necessary connection as required. |
| 74 | Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. |
| 75 | 300mm/12\\" sweep exhust fan |
| 76 | Supplying and fixing of fan hook (U hook) on celiling with 4 nos. of anchor fastener on both ends with necessary bolts and nuts and mansonry work as required. |
| 77 | Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. |
| 78 | 16 way (Double door) |
| 79 | Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper bus bar neutral buss bar, earth bar,din bar interconnection nection,powder painted including earthing etc. as required. |
| 80 | 4 Way (4+12), (Double door ) |
| 81 | Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 2 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover. |
| 82 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 83 | Supplying and fixing of Following light fitting with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire. |
| 84 | IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.).Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. 20/22 watt LED 4 feet with min. lumen output (2000- 2200) lm |
| 85 | Supplying, installation, Testing & Commissioning of 18- 22 watt LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) |
| 86 | Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required. |
| 87 | 5/6 amps switch |
| 88 | 15/16 amp switch |
| 89 | 3 pin 5/6 amp socket outlet |
| 90 | 6 pin 15/16 socket outlet |
| 91 | Supplying and fixing of following rating 240/415 volts \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 92 | Single pole upto 32 amp. |
| 93 | Single pole and neutral upto 32 amp. |
| 94 | Single pole and neutral 40 Amp |
| 95 | Single pole and neutral 63 Amp |
| 96 | TPN 40 Amp |
| 97 | TPN 63 Amp |
| 98 | Supplying and fixing single pole blanking plate in the existing MCB DB Complete etc. as required |
| 99 | SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 100 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type) |
| 101 | 100 Amp, 30 KA, FP MCCB ICU = 100% ICS |
| 102 | Aluminium Bus Bar 500 Amp set of 4 strips 12\\" |
| 103 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 104 | Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) |
| 105 | 25 sq. mm 3.5 core |
| 106 | Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete. |
| 107 | Stone agg. / Sand for an avg. lead of 10 Kms. |
| 108 | Disposal of excavated earth / mulba for an average lead of 10 Kms. Please Enable Macros to View BoQ information |