|
| 1 | Demolition of Brickwork built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions complete all as specified and as directed. |
| 2 | Demolition of cement concrete (unreinforced) of any descriptions, below or above Ground floors (Floor Topping, Sub Base etc) not exc 150mm thick, above or below ground level complete all as specified and as directed. |
| 3 | Dismantling Stone slabs and tiles of any description or thickness in floors, apronsm paved laid dry or laid dry and pointed etc complete all as specified and directed. |
| 4 | M&L for 60 mm thick coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006; M-35 Grade with grey cement and pigment complete all as specified and as directed. |
| 5 | All as per BOQ Serial item No-04 above but except tiles complete all as specified and directed. |
| 6 | M&L for 80 mm thick coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-40 Grade with grey cement and pigment complete all as specified and as directed. |
| 7 | All as per BOQ Serial item No 06 above but except tiles complete all as specified and directed. |
| 8 | M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of flooring complete all as specified and as directed. |
| 9 | M&L for laying sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 10 | M&L for pre-polished cement concrete designed coloured pavement tiles glossy finish of size not exec 0.16 Sqm of each tile of thickness 20mm thick or equivalent size as in floor set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of the tiles and laid over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. |
| 11 | M&L for hard core of gauge n.exc 63mm,deposited spread and levelled in layer n exc 15cm thick watered and rammed to a true surface of broken stone boulders to fill dipressions/pot holes and bring to proper level and gradient etc complete all as specified and as directed. |
| 12 | M&L for brick work with sub class 'B' brick straight of curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and as directed. |
| 13 | All as per BOQ Serial item No 12 above but except briks complete all as specified and directed. |
| 14 | M&L for Brick work with sub class B bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and as directed. |
| 15 | M&L for providing plain cement concrete type B1 (1:2:4) (using 20mm graded stone aggregate) as in coping and the like including weathering, slightly rounded or chamferred angles and throating as complete all as specified and as directed. |
| 16 | M&L for 100mm thick plain cement concrete type B- 2, (1:2:4) (using 40mm graded stone aggregate) as in floors, hard standings and the like complete all as speficied and as directed. |
| 17 | M&L for 75mm thick PCC (1:3:6), type C2, (using 40mm graded stone aggregate) as in plinth protection / paving, surface finished even & smooth without using extra cement as complete all as specified and as directed. |
| 18 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 19 | M&L for Exterior cladding wall tiles (Avg thickness 12-15 mm thick) glazed wall tiles (7 to 8mm thick) of approved size not less than 153mmx 76mm, colour and design as approved; set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering with cement mortar (1:3) complete all as specified and as directed. |
| 20 | M&L for Granite (of any type) tiles 10-12 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing in wall, jambs, pillars, etc with & including 10 mm thick screed bed complete all as specified and as directed.Note: Work shall be carried out in bldgs with height upto 4 storey. |
| 21 | Dismantling of plain or corrugated aesbestos sheet any gauge, thickness in roof coverings complete all as specified and directed. |
| 22 | M&L Pre-painted galvalume aluminium zinc coating GI based partially/ fully corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 23 | M&L Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.56mm of an colour having tensile strength of Alloy 31000 H4 as in ridges, Valley gutter, drip and straight to flashing (length and, fixed girth as fixed) with self tapping screws complete all as specified and as directed. |
| 24 | S&F steel Steel work of MS Square/round pipe or angles, Tee, etc as in purlins, rafters, posts and trusses including special shaped washer etc. using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specfied and directed. |
| 25 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 26 | S&F framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars, barred iron doors, iron gate, ladders; framed balusters, ways : railing : frame work of watertanks and similar work conforming Fe-290, Gde E-165 complete all as specified and as directed. |
| 27 | Excavating in post holes (or similar holes) each n.exc 0.5cu m, getting out, returning, filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding, 25cm watering & removing surplus soil to a distance n exc 50m and making good surface in any type of soil complete all as specified and as directed. |
| 28 | M&L for Cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 29 | Dismantling fencing wire mesh any type complete all as specified and as directed. |
| 30 | Dismantling posts or struts embaded in concrete, brick work, ground masonry, etc. (wood, steel or R.C.C.) any section, including taking out embedded portion etc complete all as specified and as directed. |
| 31 | S&F joist, channel, angle, or tee section, fixed independantly, without connecting plates, etc. as in fencing post conforming to Fe 410 W (gde E-250 quality B) complete all as specified and as directed. |
| 32 | S&F 11-15mm dia of shank mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long complete all as specified and as directed. |
| 33 | S&F in repairs Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and as directed. NOTE:- Each line wire to be measured. |
| 34 | S&F MS galvanised Chainlink fencing with 3.15mm dia of wire and 100 x 100mm mesh complete all as specified and directed. |
| 35 | Taking down cement plaster or lime plaster of any description from stone or brick wall/ ceiling etc including raking out joints, hacking for key scrubbing down with water including necessary working platform/scafolding as required complete all as specified and as directed. |
| 36 | M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick walls or concrete surface, finishing even and smooth (without using extra cement) etc including necessary working platform/scafolding as required complete all as specified and as directed. |
| 37 | All as per BOQ Serial item No 36 above but other then fair faces of brick work or on one side of lathing complete all as specified and as directed. |
| 38 | Preparing new plastered or previously untreated plastered surfaces of walls and M&L for applying two coats of cement base paint over & including a coat of primer complete all as specified and as directed. |
| 39 | Preparation on new plastered surfaces of wall and M&L for applying two coats of anti-algae and anti-fungal exterior grade weather coat paint over & including a coat of primer complete all as specified and directed. |
| 40 | Preparation of old plasteded surface of walls and M&L for applying one coat of cement base paint including necessary working platform/scafolding as required complete all as specified and as directed. |
| 41 | Preparation of old decorated surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds,etc and M&L for applying one coat of anti-algae and anti-fungal exterior grade weather coat paint complete all as specified and as directed.Note: Work shall be carried out in bldgs with height upto 12 storey. |
| 42 | Preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described, and M&L for applying of two coats of synthetic enamel paint over & including one coat of red oxide zinc chrom primer complete all as specified and directed. |
| 43 | M&L for one coat of synthetic enamel paint including preparation on old steel surfaces of any description over 10 cm width or girth complete all as specified and as directed. |
| 44 | Cleaning of existing floors/paved area and M&L for applying one coat of floor paint (combination of Red and yellow) on old surfaces etc complete all as specified and as directed. |
| 45 | M&L for Granite slab (of any type) 18 to 20 mm thick work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms over 15 screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade etc complete all as specified and as directed. |
| 46 | S&F in repairs Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc with L-type or J-type or cranked hook bolts etc complete all as specified and directed. |
| 47 | S&F in repairs concertina coil of dia (600/900mm) fixed in steel brackets hooked properly etc complete all as specified and directed. |
| 48 | M&L for removal of debris (Consisting of soil and consruction material) out of MOD land etc (One load contains 4.0cum) complete all as specified and as directed. |
| 49 | S&F in repairs 75mm thick precast RCPC drain cover including frame having load bearing capacity of 3MT (confirming to IS 12592) with embosing RCPC 3MT of required size as per site requirement after complete all as specified and as directed. |
| 50 | S&F in repairs 75mm thick precast RCPC drain cover including frame having load bearing capacity of 5MT (confirming to IS 12592) with embosing RCPC 5MT of required size as per site requirement after complete all as specified and as directed. Please Enable Macros to View BoQ information |