| 1 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 2 | M&L for brick work in cement mortar 1:4 of old size sub class ‘B' bricks straight or curved on plan exceeding 6mtr mean radius complete all as specified and directed. |
| 3 | All as per description of item 2.00 here-in-above but except bricks complete all as specified and directed |
| 4 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed. |
| 5 | Demolition of cement concrete unreinforced of any description in any position not otherwise specifically provided for complete all as specified and directed |
| 6 | M&L for PCC 1:4:8 type D-2 (using 40mm broken graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 7 | M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in copings, PCC block for hold fast, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed |
| 8 | Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for key scrubbing down with water complete all as specified and directed. |
| 9 | M&L for Rendering 15mm thick plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces including scaffolding at any height complete all as specified and directed. |
| 10 | Demolition of stone slabs, paver blocks and tiles of any description or thickness in floors/apron laid dry complete all as specified and directed. |
| 11 | S&F machine pressed precast concrete interlocking paver blocks with grey cement and no pigment, any shape and size conforming to IS 15658:2006 of 60mm thickness M35 grade complete all as specified and directed. |
| 12 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 13 | M&L for 75mm thick PCC, type C-1, 1:3:6, (using 20mm graded crushed stone aggregate) as in floor finish the surface complete all as specified and directed. |
| 14 | M&L for Chequered cement concrete coloured tiles 300mm x 300 mm x 25 mm thick table vibrated set, jointed and pointed in neat cement slurry with grey pigment cement and pigments as in floor over and including screed bed or bedding layer of 20 mm thick CM (1:6) as in floor, complete all as specified and directed. |
| 15 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 16 | M&L for mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 complete all as specified and directed. |
| 17 | M&L steel work in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) Forming holes with riveted, bolted, or welded attachments complete all as specified and directed. |
| 18 | Excavation in post holes not exceeding 0.50cum getting out in Hard/dense soil, returning, filling in layers not exceeding 50 mtr and making good surfaces complete all as specified and directed. |
| 19 | Dismantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings |
| 20 | S&F Prepainted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength 550 Mpa as in roof covering/cladding to walls, fixed with self taping screws complete all as specified and directed. |
| 21 | S&F pre painted galvalume aluminum zinc coated GI based plain steel sheeting 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self taping screws complete all as specified and directed. |
| 22 | M&L for reinforced concrete pipes, 450 mm bore, class NP-3, laid and jointed with collars complete all as specified and directed. |
| 23 | M&L for 100mm thick plain cement concrete 1:2:4 type B-2 (using 40mm crushed stone agg) as in floors ,ramps ,hard standing or as in similar work finished even and smooth without using extra cement including form work where required complete all as specified and directed. |
| 24 | M&L for 50mm thick PCC, type C-1, 1:3:6, ( using 20mm graded crushed stone aggregate) as in plinth protection finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 25 | M&L for Providing precast cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) louvers and jallies, 40mm thick (measured solid), including all mouldings but excluding frame, set in CM 1:4 complete all as specified and directed. |
| 26 | M & L for Providing precast cement concrete Type B-1 1:2:4 in window or door ,cills, lintels, bressumers , steps, quoin block (for use with masonry) string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pikntle block, anchorage blocks, bonders (for stone walling), corbels, brackets etc (of any section indicated) with plain fair faces, including chamfers weathering throating etc and setting in mortar complete with joints to match complete all as specified and directed. |
| 27 | Dismantling RCC posts and struts any section including taking out embedded portion in natural ground and making good disturbed surface. |
| 28 | S&F for Mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde-E-165 complete all as specified & directed. |
| 29 | S & F in repair Galvanised, (hot dip) 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed (each line wire to be measured) |
| 30 | Preparation of new steel surfaces of any description not otherwise described, over 10 cm width or girth and providing two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 31 | Supply only Chain link MS galvanised fencing of wire mesh size 50 mm x 50 (Nominal pitch of wires), complete all as specified and directed. |
| 32 | Fixing only chain link fencing incl line wires any mesh, size and type to any type of standards, rails, straining bolts, etc incl provision of binding wire complete all as specified and directed. |
| 33 | S&F MS round bar 10 mm dia as in strands for holding chain link fencing incl hooking etc complete all as specified and directed. |
| 34 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, 5 to 10 mm diameter of shank, complete all as specified and directed. |
| 35 | Dismantling timber scantling 40 Sqcm and over in section, in any position of framed work, complete all as specified and directed. |
| 36 | M&L for Non abrasive paving (rectified endura) cement concrete coloured tiles 300x300mmx10mm thick set jointed and pointed in neat cement slurry mixed with pigment laid over 15mm thick screed bed in cement mortar 1:4 including demolition/dismantling old surface/tiles complete all as specified and directed. |
| 37 | S&F machine pressed precast concrete interlocking paver blocks with grey cement and no pigment, any shape and size conforming to IS 15658:2006 of 80mm thickness M40 grade complete all as specified and directed. |
| 38 | Preparation of new plastered surfaces of walls and Materials & Labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/L and UC resistance as per IS 15489:2004 alkali and fungal resistance, dust resistance, water repellant, crack-bridging, weather proof 1st quality exterior paint of required shade with silicon additives @ 1.43L/10 Sqm and including priming coat of exterior primer applied @ 0.90L/10 Sqm and scaffolding at any height complete all as specified and directed by Engr-in-Charge. Note : - Tint/Shade shall be approved by Engr-in-Charge. |
| 39 | Dismantling of timber scantling as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed. |
| 40 | M&L for Rendering 10mm thick in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces on walls finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 41 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in surface channels and drains including formwork complete all as spd and directed. |
| 42 | Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. Please Enable Macros to View BoQ information |