| 1 | Excavation in trenches not exceeding 1.5M width and not exceeding 1.5M depth and getting out for laying of pipe etc in soft/loose soil. |
| 2 | Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25cm in in soft/loose soil. |
| 3 | Removing excavated surplus in soft/loose soil to a distance not exceeding 50M and depositing where directed and at a level not exceeding 1.5M above the starting point. |
| 4 | Material & Labour for PCC 1: 3: 6 type C1, using 20mm graded crushed trap stone aggregate & grouting in cement mortar 1:4 for making good road cutting. |
| 5 | Taking out old unserviceable GI pipe line alongwith fittings from existing connections of size 100 mm dia complete all as specified and directed. |
| 6 | All as per item No. 05 above but of size 80mm dia. |
| 7 | All as per item No. 05 above but of size 50mm dia. |
| 8 | All as per item No. 05 above but of size 40 mm dia. |
| 9 | All as per item No. 05 above but of size 25 mm dia. |
| 10 | All as per item No. 05 above but of size 20 mm dia. |
| 11 | All as per item No. 05 above but of size 15 mm dia. |
| 12 | Supply & Laying in trenches galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc as required at site of size 100 mm dia complete all as specified and directed. Note :- (i) Excavation and earth work shall be measured and paid seperately under relevant item of Sch A (ii) The rates quoted inclusive of cutting, jointing and testing of the pipe. |
| 13 | All as per item No. 12 above but of size 80 mm dia. |
| 14 | All as per item No. 12 above but of size 50 mm dia. |
| 15 | All as per item No. 12 above but of size 40 mm dia. |
| 16 | All as per item No. 12 above but of size 25 mm dia. |
| 17 | Supply & Fixing galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc and fixed complete to walls and ceilings or laid in floors all as directed of size 25 mm dia complete. Note:- (i) The rates quoted inclusive of cutting, jointing and testing of the pipe. |
| 18 | All as per item No. 17 above but of size 20 mm dia. |
| 19 | All as per item No. 17 above but of size 15 mm dia. |
| 20 | S&F gun metal gate valves with iron wheel head screwed at both ends for iron pipes complete including dismantling of old unserviceable gate valve fixed at any location of Size 50 mm dia all as directed |
| 21 | All as per item No. 20 above but of size 40 mm dia. |
| 22 | All as per item No. 20 above but of size 25 mm dia. |
| 23 | All as per item No. 20 above but of size 20 mm dia. |
| 24 | Supply and fix cast iron sluice valve PN-1.6 conforming to IS 14846/2000, ISI Mark with MS spindle and iron wheel head with both ends flanged with new rubber gasket, bolts and nuts including dismantling of old unserviceable sluice valve fixed at any location of size 300 mm dia all as directed. |
| 25 | All as per item No. 24 above but of size 250 mm dia. |
| 26 | All as per item No. 24 above but of size 200 mm dia. |
| 27 | All as per item No. 24 above but of size 150 mm dia. |
| 28 | All as per item No. 24 above but of size 100 mm dia. |
| 29 | All as per item No. 24 above but of size 80 mm dia. |
| 30 | All as per item No. 24 above but of size 400 mm dia. |
| 31 | M&L for Construction of valve chambers of size 1.0 x1.0 x 1.0 internal dimentions with 150 mm thick PCC foundation 1:4:8 type D2 using 40 mm graded trap stone aggregate, 230 mm thick brick masonary wall with sub class 'B' bricks builts in cement mortar 1:4 10 mm thick plastering to brick masonary in cement mortar internally and externally upto 15 cm below ground level, 50 mm thick coping with PCC 1:2:4 type B1 using 20 mm graded crushed trap stone aggregate valve chamber having coller frame size 1.0 x 1.0 x 1.0 made of mild steel angles of size 50mm x 50mm x 6mm and cover made of 2.5 mm thick mild steel sheet framed by 40 x 40 x 5 mm MS angle having 02 nos cross 'X' supprt fixed with coller frame by mild steel hinges - 02 Nos, locking arrangements with provision of locks and painting the steel surfaces with two coats of alluminium enameled paint over a coat of zinc chromate primer including neccessary earth work, excavation, all as specified and directed by Engineer-in-Charge . |
| 32 | All as per item No. 31 above but of size 1.2 M x 1.2 M X 1.2 M (Internal Size) |
| 33 | Providing JCB Loader to manage the breakdown and otherwise Excavation, shifting of pipes,and balancing work at any time in round the clock as per the direction of Engineer in Charge. Note:- Minimum hiring time not less than 3 Hrs |
| 34 | M & L for rectification of joint leakage of CI/DI pipeline incl excavation, return filling, leadwool, lead pig, tyton Joint, 'D' Joint, MS Clamp and short piece of CI/DI pipes as required at site etc of size 300 to 400 mm dia pipe all as required and directed at site.Note:- Contractor will have to make arrangement for T&P, drain out/ pump out water. cutting of road/ path/culvert shall be make good as per original existing without any extra cost. |
| 35 | All as per item No. 34 above but of size 200 to 250 mm dia pipe. |
| 36 | All as per item No. 34 above but of size 100 to 150 mm dia pipe. |
| 37 | All as per item No. 34 above but of size 80 mm dia pipe. |
| 38 | Repair to leakage of existing GI pipe line 15 mm to 20 mm bore in any positions (joints, fittings etc) on wall ,roof, floor etc including replacement of GI fittings such as tee ,sockets elbows,unions nipples,reducers etc incl necessary excavation and earth work complete all as directed by Engineer in Charge. Note:- (i) GI Pipe off size and Earth work for replcement of GI Pipe shall be measured and Paid separately under relevant items of this schedule. |
| 39 | All as per item No 38 above but GI Pipe of dia 25 mm to 50 mm dia |
| 40 | All as per item No 38 above but GI Pipe of dia 80 mm to 100 mm dia |
| 41 | M & L for Taking out Sluice valve of size 250 to 300 mm dia for Refacing, Regrinding, Opening all parts at site and replacement of UNSV parts like MS Spindle, U clamp check Nut, Brass Gate, gasket seel, glands, nut, bolts, washer etc and refixing complete after repair at site as directed by Engineer in Charge. |
| 42 | All as per item No. 41 above but Sluice valve of size 150 to 200 mm dia. |
| 43 | All as per item No. 41 above but Sluice valve of size 80 to100 mm dia. |
| 44 | S&F of CI Detachable joint with nut bolts complete suitable for CI/DI pipe line of 50mm bore size with and incl all jointing material complete all as specified and directed. Note:- The rate quoted by contractor deemed to be incl necessary earth works. |
| 45 | All as per item No. 44.00 here-in-before but of size 80 mm dia |
| 46 | All as per item No. 44.00 here-in-before but of size 100 mm dia |
| 47 | S&F of DI Mechanical joint (MJ) collar with rubber ring complete suitable for CI/DI pipe line of 100mm bore size with and incl all jointing material complete all as specified and directed. Note:- The rate quoted by contractor deemed to be incl necessary earth works. |
| 48 | All as per item No. 47.00 here-in-before but suitable for pipe of size 150mm dia |
| 49 | S & F in repalcement of Bib tap standard of PTMT any colour high pressure screwed for iron pipe suitable for 15mm dia complete all as specified and directed. |
| 50 | All as per item No. 49.00 here-in-before but of size 20 mm dia |
| 51 | S & F in repalcement of Stop cock standard of PTMT any colour high pressure screwed for iron pipe suitable for 15mm dia complete all as specified and directed. |
| 52 | All as per item No. 51.00 here-in-before but of size 20 mm dia |
| 53 | Taking up old UNSV CI/DI pipe incl all fittings with spigot and socket ends and lead joint of size 100mm bore complete all as specified and directed. |
| 54 | All as per Item No. 53.00 here-in-before but of size 150mm bore. |
| 55 | Supply, laying and testing of Ductile iron pipe (Conforming to IS: 8329-2000), Centrifugally Cast (Spun) Pressure Pipe with Socket and Spigot ends suitable for Push-on-Joint incl jointing material, duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and Cement Motor Lining with Bituminous Seal Coat on internal surfaces complete of size 100mm bore class K-9 laid in trenches complete all as specified and directed . |
| 56 | All as per Item No. 55.00 here-in-before but of size 150mm bore. |
| 57 | M&L for ductile iron fittings suitable for CI/DI pipe of size 80mm to 400mm bore and any type, class K-12, such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces (single branch, \\"Y\\" junction, double branch, cross etc), caps and plugs etc, complete all as specified and directed. |
| 58 | Supply and fixing MS clamp made out of 150mm x 5mm with 40/25/20mm dia hole for taking branch connection with and including fixing of 40/25/20mm dia GI socket duly welded complete including fixing of clamp on existing GI pipe line of size 50/80/100/150mm dia with suitable rubber gasket packing to ensure leak proof joint and suitable nuts, bolts and washers etc complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |