| 1 | Demolition of brick work or stone/boulder masonry including all quoins, arches, pillars, etc, built in cement mortar complete all as specified and directed. |
| 2 | Dismantling posts or strut (wood, steel or R.C.C.) any section, including taking out embedded portion in ground or in cement concrete brick work,masonary etc and making good disturbed ground complete all as specified and directed. |
| 3 | M&L for brick work with flyash bricks , using old size bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.. |
| 4 | Dismantling jarfi wall/RCC jallies fixed in rcc post complete all as specified and directed. |
| 5 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, n exc 10 sqm on plan and n exc 1.5m in depth and getting out any type of soil complete all as specified and directed. |
| 6 | M&L for Cement concrete type D-2 1:4:8 (using 40 mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 7 | RCC (Design mix M-25) in foundations, including, rafts, footings, foundation beams, bases for columns, etc , basement slab, under reamed piles and mass concrete complete all as specified and directed.Note:- Reinforcement shall be measured and paid separately under respective item. |
| 8 | RCC M-25 design mix as in columns , pillars, piers, posts and struts etc.complete all as specified and directed.Note:- Reinforcement shall be measured and paid separately under respective item. |
| 9 | RCC (Design mix M-25) in beams, cantilevers, bressumers, lintels over 1.50 m span complete all as specified and directed.Note:- Reinforcement shall be measured and paid separately under respective item. |
| 10 | Use and waste Formwork to sides of concrete fdn, footings, bases of cols, raft and raft beams, sides and soffits of fdns and plinth beams and similar works vertical or to batter, rough finish surfaces of concrete complete all as specified and directed. |
| 11 | Use and waste Formwork to sides of pillars,posts,struts,piers,cloumns and stanchions rough finish surfaces of concrete complete all as specified and directed. |
| 12 | Use and waste formwork to sides and soffits of floor beams, roof beams , beam haunchings girders, lintels, cantilevers etc to plain surface complete all as specified and directed. |
| 13 | Removing excavated materials n. exc. 50 m and depositing were directed at a level n exc 1.5 mtr above the staring point. |
| 14 | Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm etc complete all as specified and directed |
| 15 | M&L TMT steel bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) complete all as specified and directed. |
| 16 | M&L TMT steel bars 5mm dia and over, up to and including 10mm dia in stirrups spcers and binders complete all as specified and directed. |
| 17 | S&F in Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified and directed. |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 19 | Demolition of PCC of any description and any position not otherwise provided for complete all as specified and directed |
| 20 | M&L for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165etc complete all as specified and directed. |
| 21 | M&L for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and strainingand fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc. complete all as specified and directed. |
| 22 | M&L for 15 mm thick rendering in CM 1:4 on stone masonry surfaces or surfaces other than fair faces of brick work, finished fair and even complete all as specified and directed. |
| 23 | Material & Labour for preparation of new/old external surfaces of wall/ceiling and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces incl coat of putty scraping (using Mechnical sprayer scraper etc) surfaces, complete all as specified and directed. |
| 24 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone agg) as in seismic and other similar bands, coping, bed block or similar work including necessary form work complete all as specified and directed. |
| 25 | M&L for preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified |
| 26 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated,10 Sqmm 4 core screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion complete all as specified and directed. |
| 27 | Supply and laying in trenches/under roads/crossings or fixed to wall/pole/roof, GI tubing light grade of 50 mm for protection of UG cables complete all as specified and directed. |
| 28 | Supply and laying in trenches/under roads/crossings or fixed to wall/pole/roof, GI tubing light grade of 15 mm for protection of UG cables complete all as specified and directed. |
| 29 | Supply and laying sand cushioning with dry and clean washed sand over and under the under ground cable in trenches, ducts for cable protection complete all as specified and directed. |
| 30 | Supplying and laying unreinforced precast concrete cable cover, class LV Type 2 flat, size 300mm x 180mm x 40mm complete all as specified and directed. |
| 31 | Supply and errect Steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with MS base plate, finial taper plug, bolts, nuts, screws and top cover, with single swan neck bracket all as specified, directed and including the following:- (a) Excavation in trenches not exceeding 1.5 mtr wide and 1.6 mtr deep for pole foundation and getting out in soft/loose soil, returning filling in the excavation of soil after fixing the pole in foundation ramming earth around in layer not exc 25cm thick and disposal of surplus soil to a distance not exc 50 mtrs. (b) Material and labour for providing PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in foundation, 600 mm x 600 mm cross section for 150 mm and PCC 1:3:6 type C-2, using 40mm graded stone aggregate as in foundation, 600 mm x 600 mm cross section planting depth 1.5 mtr for concrete casing the pole upto GL complete all as directed. (c) Material and labour for providing PCC 1:2:4 type B-1, using 20mm graded stone aggregate for plinth block/collar above GL 300 mm high and 600 mm x 600 mm cross section all as directed. (d) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/concrete collar with two coat of aluminium paint over a coat of red oxide steel primer for preparation of surface complete all as specified and directed. |
| 32 | Supply and fix in repairs road lighting luminaires, 90 watts, 230 Volt high power IP 65/66 rated LED with unique peanut lens for uniform distribution, higher spacing between poles, fixing it in new bracket (painting the bracket with one coat of red oxide and one coat of aluminum paint) and connecting it with pole mounted junction box with 2.5 sqmm 2 core copper conductor complete all as specified and directed. |
| 33 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth lead wire 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. complete all as specified and directed. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. complete all as specified and directed. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 20 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Total Quantity of common salt 60 kg and charcoal 25 kg in a ratio 3:1should be maintained in alternat 3 to 4 layers complete all as specified and directed. (f) Testing of earthing. complete all as specified and directed. |
| 34 | S&F in repair earth continuity conductor or main earth lead of aluminium strip 25 x 3.15 mm with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as specified and directed. |
| 35 | M&L for PCC (1:2:4) type B2 using 40 mm graded stone aggregate as in foundation, filling, mass concrete and pilasters, buttresses columns, posts etc complete all as specified and directed. |
| 36 | Supply and fix junction box made out of polycarbonate with IP 65 protection of specified size for 10-16 sqmm XLPE cables,having terminals for termination of cable with necessary nuts and bolts, including polycarbonate cable gland, 01 Nos rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete all as specified and directed. |
| 37 | S&F in repairs three core PVC insulated cables 1.5 Sqmm size, 1100 Volt grade with copper conductor and drawing into street light brackets/PVC Conduits and connecting with Junction Box and Street light fittings including continuous PVC insulated copper conductor three core copper conductor of size 1.5 Sqmm complete all as specified and directed. |
| 38 | M&L for cable root indicator MS sheet embossed with LT 1100 Volts Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified and directed. |
| 39 | S&F in repairs Infrared sensor based NATURE SWITCH three phase 8 kw consisting of power contactor, AC conforming to IEC - 60947 - 4 - 1/ IS - 13947 - 4 - 1 for load switching and terminal blocks. The enclosure is made of UV stabilized, FR grade special moulding compound to provide a rust proof, electric shock proof, termite proof, outdoor mountable electrically insulating body capable of enduring solar radiation in the outdoor & suitable for mounting. The enclosure is provided with mounting brackets, cable glands, openable door with lock and key. Selectable options for duration based switching OFF as well as override facility for maintenance should be available complete all as specified and directed. |
| 40 | Deduct schedule of credit amount Rs. 30,575.00 to be deducted during AOC Please Enable Macros to View BoQ information |