| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in soft/ loose soil complete all as specified and as directed. |
| 2 | Removing excavated material /soil to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed |
| 3 | M&L for Sand filling in trenches using dry river sand as cushioning to under ground cable including spreading, levelling and consolidation complete all as specified and directed.[Note: Punned thickness of sand shall only be measured.] |
| 4 | Returning filling in, including spreading, levelling,watering and well ramming in layers not exc 25cm thickness as in soil complete all as specified and directed. |
| 5 | Supply and laying common burnt burnt building clay bricks of sub-class 'B' designation 75 old size laid along alignment of cables as protection to cables in trenches complete all as directed |
| 6 | M & L for laying 100mm dia GI pipe light grade laid for cable protection at road crossings or fixed on walls / poles secured with clamps complete all as directed |
| 7 | M & L for laying 80mm dia GI pipe light grade laid for cable protection at road crossings or fixed on walls / poles secured with clamps complete all as directed |
| 8 | M & L for laying 50mm dia GI pipe light grade laid for cable protection at road crossings or fixed on walls / poles secured with clamps complete all as directed |
| 9 | M & L for boring holes horizontally under road, pavements, hard standing by trenchless technology using sounding technique and necessary machine including inserting and providing 150mm dia HDPE pipe suitable for 0.4 mpa working pressure complete all as directed. |
| 10 | Supply and laying unreinforced precast concrete cable covers of class HPV, type-1, flat of size 300x180x40mm laid in trenches along alignment of cable for protection complete all as directed |
| 11 | M & L for 100mm thick, PCC 1:2:4, type B-2, using 40mm graded stone aggregate as in pavement / hard standing, etc finished by brooming laid in alternate bays including taking down carefully existing interlocking paver blocks of any size, pattern and thickness and relaying at the same location after concreting as directed by the Engineer-in-Charge |
| 12 | Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to galvanised earth strip 32x6mm [Earth Lead] and GI pipe 40 mm dia light Grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI bolts & nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to earthing test point including testing on completion including PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm angle iron, MS funnel with 20 mm bore medium grade GI Watering pipe, wire mesh, earth work excavation, returning filling, removal of surplus soil etc. including removing old unserviceable earthing set complete all as specified and as directed. |
| 13 | S & F Cable Jointing Kit for 11 KV [Earthed] Grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and as directed. |
| 14 | S & F Cable Jointing Kit for 11 KV [Earthed] Grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm, complete all as specified and as directed. |
| 15 | S & F Cable Jointing Kit for 11 KV [Earthed] Grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and as directed. |
| 16 | S & F Cable Jointing Kit for 11 KV [Earthed] Grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm, complete all as specified and as directed. |
| 17 | Supplying, laying and testing HT UG cable [earthed], XLPE insulated, screened insulated, steel strip armoured and PVC bedded, 11000 Volts grade [heavy duty] with aluminium conductor of size 3 Core 240 Sqmm laid in trenches, fixed to walls or passing through pipes and connecting up including taking out old unserviceable cable complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 18 | Supplying, laying and testing HT UG cable [earthed], XLPE insulated, screened insulated, steel strip armoured and PVC bedded, 11000 Volts grade [heavy duty] with aluminium conductor of size 3 Core 240 Sqmm laid in trenches, fixed to walls or passing through pipes and connecting up including taking out old unserviceable cable complete all as specified and as directed. Please Enable Macros to View BoQ information |