| 1 | Schedule 'A' |
| 2 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises, complete all as specified and directed by Engineer-in-Charge. |
| 3 | Taking down chowkhat with shutters (without taking of shutters from the frames of any description not exceeding 1.5 Sqm in each panel, complete all as specified and directed by Engineer-in-Charge. |
| 4 | Taking down chowkhat with shutters (without taking of shutters from the frames of any description exceeding 1.5 Sqm but not exceeding 4.0 Sqm in each panel, complete all as specified and directed by Engineer-in-Charge. |
| 5 | Demolition of Concrete of any description and in any position not otherwise specifically provided, complete all as specified and directed by Engineer-in-Charge. |
| 6 | Dismantling/ Demolition of brick work or stone masonry or RCC Pre cast Jali & Jafari built in cement mortar including all quoins, arches, pillars, etc., complete all as specified and directed by Engineer-in-Charge. |
| 7 | Taking down cement plaster on stone wall including racking out joints, hacking for key scrubbing with water etc., complete all as specified and directed by Engineer-in-Charge |
| 8 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided, complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply & Fixing 2nd class HW plain chowkhats and framed, rebated on the solid rounded or chamfered put together with glue pinned at joints, complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply & Fixing for 35mm thick Flush Shutter, solid core construction, with block board core and plywood face panels, both face is covered with decorative face veneer with lipping/ frame to match commercial type on both side, complete all as specified and directed by Engineer-in-Charge. |
| 11 | Providing 18-19mm thick factory made 100% solid WPC (Wood polymer composite) Solid Plain / Prelam / Enrouted Plain / Enrouted Painted flush Door Shutter of required size comprising of Virgin PVC resin of K Value 57-60 (Suspension Grade), Calcium carbonate and natural fibres (Wood Powders / rice husk / Wheat husk) and Non-toxic additives made from Extrusion process WPC foam sheet single Extruded (Inner) with density not less than 650 Kg/cum manufacture by an ISO 9001-2015 Certified Company, having good screw holding capacity (Screw withdrawal strength of 2000 N (face) & 1100 N (Edge), Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread flame of Class A category with Property of being Termite/Borer Free, Water/Moisture Proof, Fire Retardant and fixing with Stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws for WC/Bathroom/Toilet/Kitchen/Balcony Doors, complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply & Fixing for factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (±0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding interlock (one vertical length in each shutter) (45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick galvanized steel frame (30mm x 18mm) 2 Nos, sliding sash (30mm x 18mm) 2 Nos, sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100m long fastener. Hardware (touch lock of zinc alloyed (white powder coated), steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate excludes cost of glass and includes all other connected accessories) area not exceeding 2.00 sqm each fixed from ground floor to any height of floors, complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supply & Fixing factory made uPVC white colour fixed window/ventilator made of extruded profile with wall thickness of 2.3 mm (±2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (one vertical length in between two shutters) (60mm x74mm). Glazed bead (35mm x 20mm) will be mitered cut and fusion welded at all corners. Including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick. galvanized steel frame (28mm x 21.5mm), T profile (27mm x 17mm) to be inserted in repair profile. Frame will be fixed to the wall with 8mm x 100mm long fasteners. 5mm thick glazing with selected quality glass (Note: The unit rate excludes cost of glass and includes all other connected accessories.) area not exceeding 1.00 sqm each fixed from ground floor to any height of floors, complete all as specified and directed by Engineer-in-Charge. |
| 14 | Preparation of new or previously treated wood surfaces of any description, over 10 cm width or girth, not otherwise described applying one coat of pink primer and applying two coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supply & Fixing 300mm long brass ordinary rat tail rod pattern springs including roller and roller, complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply & Fixing 100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply & Fixing 150mm long Extruded Aluminium alloy handles, fabricated type, and anodised, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply & Fixing 150mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply & Fixing 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy, complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply & Fixing Hasp and staple for 100mm, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply & Fixing 140mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Supply & Fixing 5mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply & Fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium/pvc sections, complete all as specified and directed by Engineer-in-Charge. |
| 24 | Material & Labour for 20 to 25mm thick machine cut Kota stone (single piece of required size for steps) flooring over cement screed base laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and Mirror polishing complete all as specified over and including 15mm thick screed bed in Cement Mortar 1:4, complete all as specified and directed by Engineer-in-Charge. |
| 25 | ditto - all as above but kota stone slab (100/150mm x 550mm) and 20-25mm thick in riser of steps, skirting, dados and pillar laid over and including 10mm thick rendering to receive the stone in cement mortar 1:3 and jointed, complete all as specified and directed by Engineer-in-Charge.Note:- Kota stone in Stair case should be provided in single piece upto 1.5 Metre length |
| 26 | Material & Labour for PCC (1:2:4) type B-0 using 12.5mm graded aggregate as in floor of average 25mm thick, complete all as specified and directed by Engineer-in-Charge. |
| 27 | Material & Labour for 75mm thick cement concrete type C–1 (1:3:6) using 20mm graded stone aggregate as in plinth protection etc., complete all as specified and directed by Engineer-in-Charge. |
| 28 | Material & Labour for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and including 15mm cement plaster in 1:4 Cement Mortar, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Material & Labour for granite (of any type) 20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including, grinding, polishing, moulding the edges and polishing and including over screed bed 20mm thick in cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge. |
| 30 | Material & Labour for precast RCC 1:2:4 Type-B1 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face, set in Cement Mortar 1:4, complete all as specified and directed by Engineer-in-Charge. |
| 31 | Material & Labour for Porbandar stone masonry, well bonded, bedded and solidly hearted built in Cement Mortar 1:6, complete all as specified and directed by Engineer-in-Charge. |
| 32 | Material & Labour for rendering 5mm thick on ceiling concrete surfaces in cement mortar 1:3 and even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 33 | Material & Labour for rendering 15mm thick on stone surfaces in cement mortar 1:4 and even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 34 | Material & Labour for 15mm thick rendering in Cement Mortar 1:6 to stone surfaces trowelled to even & smooth w/o using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 35 | Material & Labour for preparing surfaces plastered or unplastered new surface of walls applying two coats of oil bound distemper over a coat of primer over layer of smooth Putty finish as per manufacture instruction with smooth roller finish, complete all as specified and directed by Engineer-in-Charge. Note: - After painting, cleaning of all floors, glass & furniture by own arrangement. |
| 36 | Material & Labour for complete removal of existing treatment by washing down and smoothing old surface of walls including scrapping and applying two coats of oil bound distemper over a coat of primer over layer of smooth Putty finish two coats as per manufacture instruction with smooth roller finish, complete all as specified and directed by Engineer-in-Charge. Note: - After painting, cleaning of all floors, glass & furniture by own arrangement. |
| 37 | Material & Labour for preparing surfaces plastered or unplastered new surface of ceiling applying two coats of oil bound distemper over a coat of primer on smooth putty finish two coats as per manufacture instruction with smooth roller finish, complete all as specified and directed by Engineer-in-Charge. Note: - After painting, cleaning of all floors, glass & furniture by own arrangement. |
| 38 | Material & Labour for preparing surfaces plastered or unplastered old surface of ceiling applying two coats of oil bound distemper over a coat of primer two coats as per manufacture instruction with smooth roller finish, complete all as specified and directed by Engineer-in-Charge. Note: - After painting, cleaning of all floors, glass & furniture by own arrangement. |
| 39 | Material & Labour for complete removal of old plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over a coat of smooth putty all as per the manufacturer’s instructions, complete all as specified and directed by Engineer-in-Charge. |
| 40 | Material & Labour for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over a coat of smooth putty all as per the manufacturer’s instructions, complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply & Fixing 110mm dia PVC rain water pipe of pressure single socketed with rubber joint, jointed with solvent joint fixed to wall, complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supply & Fixing 110mm dia PVC band any radius, complete all as specified and directed by Engineer-in-Charge. |
| 43 | Supply & Fixing in repair Harrison rails stainless steel (Curtain rod/drapery rod), 20mm dia, powder coated with and including fancy type bracket 2 Nos of each opening and side stopper fancy type powder coated of required shape and size 2 Nos of each opening, complete all as specified and directed by Engineer-in-Charge. |
| 44 | Roughening surfaces of old concrete floor by picking sweeping cleaning & washing down with water to remove dust etc., including removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00 Kg/Sqm, complete all as specified and directed by Engineer-in-Charge. |
| 45 | Material & Labour for 40mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in padding to roof slab and rendering 5mm thick in one layers on concrete surface cement sand mortar 1:3 using water proofing compound as per manufacturer’s instruction finished even fair and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. Note: - WPC will be measured and paid separately under respective Item. |
| 46 | Material & Labour for providing APP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3KG/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely.(ii) Applying APP based pre-fabricated with non-woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method.(iii) Applying a coat of solar reflective bituminous aluminium paint @ 0.10Kg/Sqm over mineral surface. |
| 47 | Supply only liquid water proofing compound, complete all as specified and directed by Engineer-in-Charge. |
| 48 | Material & Labour for weld-mesh of size 75x75x3mm to be wrapped on the exposed surface of rib of beam & on the slab bottom and tack welding to the exposed reinforcement at close intervals and applying Cement Mortar 1:3 all in complete as per the technical specifications and manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge. |
| 49 | Supply & Fixing Joist, channel, angle, or tee sections, Fe-410-W (Gde- E-250) quality-B fixed independently, without connecting plates, etc., complete all as specified and directed by Engineer-in-Charge. |
| 50 | Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed by Engineer-in-Charge. |
| 51 | Material & Labour for preparing new surface of steel of any desc over 10 cm width or girth and applying two coat of synthetic enamel paint over red oxide primer, complete all as specified and directed by Engineer-in-Charge. |
| 52 | Material & Labour for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in filling in chowkhats, hold fast block etc., complete all as specified and directed by Engineer-in-Charge. |
| 53 | Chipping of loose/ damaged /cracked / previously repaired / delaminated or weak concrete by chiselling to expose the sound core concrete where ever required and to expose rusted reinforcement upto depth not exceeding 50mm and disposal of rubbish off the premises to a distance not exc 50 mtrs including cleaning of reinforced concrete surface by air compressor, complete all as specified and directed by Engineer-in-Charge. |
| 54 | Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using product: Rustoff-100 of Sika or equivalent make in Fosroc/ Thermax as approved by GE, with density 1.01 Kg/ltr at 30 degree celsius and consumption : 0.2 Kg/Sqm/coat, complete all as specified and directed by Engineer-in-Charge. Note: The mtrl to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar). |
| 55 | Supply and apply a cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and Product requirements: carbonation resistance: 2mm of Sika Top Armatec ®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20mm of normal mortar; bond strength > 1N / Sqmm according to ASTM C 882-78, complete all as specified and directed by Engineer-in-Charge. Note: The mtrl to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar) |
| 56 | Material & Labour for Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer's specification including preparation of surface thoroughly and cleaning complete where ever required with using Product: Sikadur ®-32 LP of Sika or equivalent in Fosroc / Thermax as approved by GE with Consumption: 0.4 kg/Sqm and Product requirements: Complies with ASTM C 881-78, Type II Grade 2 Class B+C, complete all as specified and directed by Engineer-in-Charge. |
| 57 | Material & Labour for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete surface in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply and apply a ready to use non shrink, cementitious free flow micro-concrete (<100mm) using Product: Sika Rep® Microcrete-4 + adequate coarse aggregate, Yield: approx 17 Ltr/bag (30 Kg) (depending on the size and quantity of coarse aggregate added), Product : Sika Rep ® Microcrete-4 or equivalent make in Fosroc / Thermax as approved by GE, Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99, complete all as specified and directed by Engineer-in-Charge. Note: 1 Providing and erecting hydraulic & manual steel props upto full height, braced at centre, resting on wedge and block to support the structure provisionally during repair work .This is not paid separately. Note: 2 Providing and fixing water tight centering and shuttering including bolting, strutting, propping etc. including removal of form work from column, beam etc. complete as per site requirement. This is not paid separately. |
| 59 | Material & Labour for CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge. |
| 60 | -ditto- all as per item No. 58 above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders, complete all as specified and directed by Engineer-in-Charge. |
| 61 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and directed by Engineer-in-Charge. |
| 62 | Material & Labour for Hard-core of broken stone or boulders gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer-in-Charge. |
| 63 | Material & Labour for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors, complete all as specified and directed by Engineer-in-Charge. |
| 64 | Material & Labour for 80mm thick M-40 Grade Machine pressed precast concrete paver block of any colour any shape and size confirming to IS 15658-2006 with grey cement and pigment, complete all as specified and directed by Engineer-in-Charge. |
| 65 | Material & Labour for 50mm thick Sand filling under floors or in foundation including watering and consolidation, complete all as specified and directed by Engineer-in-Charge. |
| 66 | Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cills, bed blocks, copings, bed plates, bond stones, etc., including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work, complete all as specified and directed by Engineer-in-Charge. |
| 67 | Excavating in trenches, not exceeding 1.5 Metre wide and not exceeding 1.5 Metre depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5 Metre in depth for shafts, cesspits, manholes, pier holes, etc and getting out in loose/soft soil, complete all as specified and directed by Engineer-in-Charge. |
| 68 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each, complete all as specified and directed by Engineer-in-Charge. |
| 69 | Removing excavated soil not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge. |
| 70 | Material & Labour for pre cast RCC jali 35mm thick in PCC 1:2:4 type B0 using 12.5mm graded stone aggregate set and jointed in Cement Mortar 1:4 including dismantling of old jali, complete all as specified and directed by Engineer-in-Charge. |
| 71 | Material & Labour for precast RCC 1:2:4 Type-B1 (using 20mm graded crushed stone aggregate) as in manhole and drain cover slab and similar article with plain faces, set in cement Mortar 1:4, complete all as specified and directed by Engineer-in-Charge. |
| 72 | Re-fixing for 80mm thick M-40 Grade Machine pressed precast concrete paver block of any colour any shape and size confirming to IS 15658-2006 with grey cement and pigment, complete all as specified and directed by Engineer-in-Charge. |
| 73 | Material & Labour for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors, complete all as specified and directed by Engineer-in-Charge. |
| 74 | Material & Labour for Pre-cast cement concrete block masonry (Type C-1, 1:3:6 (20mm aggregate) in with solid blocks, exc. 10 cm in width and setting in Cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge. |
| 75 | Supply & Fixing Rolled sections of grade Fe 410 as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, complete all as specified and directed by Engineer-in-Charge. |
| 76 | Material & Labour Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to GDE Fe410-0 or Fe 310-O, complete all as specified and directed by Engineer-in-Charge. |
| 77 | Supply & Fixing Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed by Engineer-in-Charge. |
| 78 | Supply & Fixing Pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screw, complete all as specified and directed by Engineer-in-Charge. |
| 79 | Supply & Fixing Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screw, complete all as specified and directed by Engineer-in-Charge. |
| 80 | Material and labour for powder coated Aluminium Anodised frame (minimum thickness of powder coating 50 micron) for door, sliding windows & ventilators with one or more rebates including joining cleats for fixing etc., complete all as specified and directed by Engineer-in-Charge. |
| 81 | Material and labour for powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc., complete all as specified and directed by Engineer-in-Charge. |
| 82 | Supply & Fixing 4.8mm thick ordinary glass, pin headed type and glazing with/ without oil putty in squares not exceeding 0.5 Sqm in each pane in metal or aluminium window, complete all as specified and directed by Engineer-in-Charge. |
| 83 | Supply & Fixing 125mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-22, complete all as specified and directed by Engineer-in-Charge. |
| 84 | Supply & Fixing 65mm Aluminium mortice lock vertical type 2 lever, complete all as specified and directed by Engineer-in-Charge. |
| 85 | Material & Labour for two coats of anticorrosive Epoxy Paint over a coat of primer on steel & iron surfaces over 10cm width or girth including preparation of new surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 86 | Material & Labour for Mild steel screw bolts (machine made) of dia 11 to 15mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm long, complete all as specified and directed by Engineer-in-Charge. |
| 87 | SCHEDULE 'A' E/M |
| 88 | Taking down carefully copper /aluminium point wiring (light, fan, socket or power point) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, socket, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition separately) and making good distribution surfaces of walls, floors, etc., complete all as specified and directed by Engineer-in-Charge. |
| 89 | Taking down electric connections and taking down old unserviceable MCB SPN/SP/TPN/MS, DB's etc., of any capacity, complete all as specified and directed by Engineer-in-Charge. |
| 90 | Taking down Ceiling fan, sealing cable end, dismantling blades and removing fan and blades and deposit to E/M store, complete all as specified and directed by Engineer-in-Charge. |
| 91 | Material & Labour for Point wiring complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non-metallic rigid heavy duty concealed steel conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules, complete all as specified and directed by Engineer-in-Charge.for the following:- |
| 92 | One light point controlled by one, one way switch |
| 93 | One Ceiling fan / exhaust fan point controlled by one, one way switch |
| 94 | Supply & fixing Rotary isolator Flameproof switch 1 way, 16 Amps, DP with termination box, complete all as specified and directed by Engineer-in-Charge. |
| 95 | Supply & Fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed by Engineer-in-Charge. |
| 96 | Supply and fixing LED light fitting 30 Watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed by Engineer-in-Charge. |
| 97 | Supply & Fixing Flameproof Ceiling fan having 1200mm blade sweep 1440 RPM, including flame proof fan regulator operating voltage 220-240 V and frequency 50 Hz, and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling to the fan, complete all as specified and directed by Engineer-in-Charge. |
| 98 | Supply & Fixing Flameproof exhaust fan having 450mm blade sweep 1440 RPM, operating voltage 220-240 V and frequency 50 Hz, with louvers and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling to the fan, complete all as specified and directed by Engineer-in-Charge. |
| 99 | Supply & Fixing of Flameproof MCB DB 4 way SPN, double door, type, IP - 53 with 200 Amps rated bus bar, Concealed and connecting up, complete all as specified and directed by Engineer-in-Charge. a) Incoming MCB 32 Amp DP--01 nos. b) Outgoing MCB 16 Amp SP--02 nos. |
| 100 | Supply & fixing Flameproof 4/3 way junction box 100mm dia, complete all as specified and directed by Engineer-in-Charge. |
| 101 | Supply & fixing Flameproof MS conduit 300mm long flexible pipe with both end brass screw plug, complete all as specified and directed by Engineer-in-Charge. |
| 102 | Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 25 Sqmm 4 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc., all connections, complete all as specified and directed by Engineer-in-Charge. |
| 103 | Supply and laying 50 /38mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor, complete all as specified and directed by Engineer-in-Charge. |
| 104 | Material & Labour for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well ramming watering finish surface 10 cm from top using PCC 1:3:6; including removal of surpluses soil, complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |