| 1 | Demolition of plain cement concrete (Un reinforced) in benching and surface channels,bedding etc above ground level. |
| 2 | Demolition of cement concrete bed in haunching and breaking up RCC drain pipes set in cement mortar of 150 mm Dia |
| 3 | Demolition of cement concrete bed in haunching and breaking up RCC drain pipes set in cement mortar of 200 mm Dia |
| 4 | Demolition of cement concrete bed in haunching and breaking up RCC drain pipes set in cement mortar of 300 mm Dia |
| 5 | Excavation in trenches n.exc 1.5m deep and n.exc 1.5m wide in manholes,etc. n getting out any type of Soil in foul water position |
| 6 | M&L 150mm dia RCC pipes class NP-2 with collars laid in treches with cement joint and tested including Cement Concrete 1:4:8 type D2 bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed . |
| 7 | M&L 200mm dia RCC pipes class NP-2 with collars laid in treches with cement joint and tested including Cement Concrete 1:4:8 type D2 bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed . |
| 8 | M&L 300mm dia RCC pipes class NP-2 with collars laid in treches with cement joint and tested including Cement Concrete 1:4:8 type D2 bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed . |
| 9 | M&L for plain cement concrete 1:3:6 Type C2 using 20mm graded aggregateas in foundation, filling in mass concrete complete all as specfied as directed |
| 10 | M&L for plain Cement concrete 1:2:4 Type B1 using 20 mm graded aggregate as in benching/kerbing or surface channel etc complete |
| 11 | M&L for plain cement concrete 1:3:6 Type C1 using 20mm graded aggregate as in coping including form work etc complete. |
| 12 | Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars ,etc, all as specified and directed. |
| 13 | M&L for Pre-cast cement concrete block masonry with solid blocks, Type D-5, 1:5:8, exc. 10 cm in width and setting in mortar, complete, built in cement mortar (1:6) all as specified & directed. |
| 14 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. |
| 15 | Rendering 15mm thick in cement mortar 1:4 on brick surfaces / concrete finished even smooth with spong finish without using extra cemnet complete all specified and directed. |
| 16 | M & L for cutting in to existing manhole for connectiing new drain 150/200/300 mm bore , making good to pipe & renderring cutting out existing benching for & forming branch channel in cement concrete ( 1:2:4) type B1 smooth finished & reforming benching as requierd. |
| 17 | Returning filling in soil including spreading, levelling and well ramming in layers n.exc 25cm thick in layer etc all complete. |
| 18 | Removing excavated soil n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 19 | Cleaning of manholes upto 1.00m depth by means of removing the silt, sludge, etc & baling out water complete manually or mechanically and removing the sludge all as specified |
| 20 | Cleaning of manholes exceeding 1.00m but not exceeding 2.00m depth by means of removing the silt, sludge, etc & baling out water complete manually or mechanically and removing the sludge |
| 21 | Cleaning of choked sewage lines of any bore of pipe including drains by roding and well flushing with water taking out waste materials any quantity and depositing where directed |
| 22 | Dewatering and desludding of foul water and Slude from soakage wells/Septic tanks manually or mechanically as directed by Engineer-in-Charge. |
| 23 | M&L for removal of blockage in between WC and nahani trap/WC to 1st manhole/floor trap to nahani trap etc, by flexible roding and removal the all dirt upto a distance of 100m all as directed by Engineer-in-charge. |
| 24 | Extra forming fair finished drain or channel inner girth n.exc 30 CM in cement, concrete using extra cement including forms, moulds, mitred/stopped ends etc complete. |
| 25 | M&L extra for forming fair finished drain or channel 45 cm inner girth in cement concrete using extra cement incl, forms mould, mi-tred/stopped ends etc. |
| 26 | M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of white wash complete all as specified. |
| 27 | Dismantling of floors health or walls tiling and Stone floor including cement mortar bedded (but not backing) & removing serviceable tiles to store and rubbies of the premises |
| 28 | M/L PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub bases, 75 mm thick complete. |
| 29 | M&L for precast coloured, chequered cement concrete tiles, glossy finish of size 300 x 300mm x 20mm thick, conforming to IS-1237 (2006) set jointed and pointed in neat cement slurry in floor laid over and including 20mm thick screed bed in CM (1:6). |
| 30 | Dismantaling Stone slabs and tiles of any description or thickness in floors,laid dry or aprons etc |
| 31 | M&L for Machine pressed coloured Glossy finish precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, M-35 Grade including 30 mm thick grit/stone dust cushioning all as specified. |
| 32 | Fixing only interlocking tiles of any thickness and size including 30 mm thick sand cushoning complete all as spd and directed. |
| 33 | Dismantling of cast iron RCC, AC or PVC pipe jointed in CM any dia bore |
| 34 | PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm dia out let |
| 35 | S&F PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls |
| 36 | S&F PVC (SWR) pipes of 75 mm dia, single socket fixed to walls |
| 37 | S&F PVC (SWR) bends with or without access door of 110 mm dia, any radius |
| 38 | S&F PVC (SWR) bends with or without access door of 75mm dia, any radius |
| 39 | (PVC (SWR) vent cowl, 100 mm dia |
| 40 | Providing precast cement concrete 1:2:4 Type B1 using 20 mm graded aggregate, in cover slabs (for man holesetc.) set in CM 1:6 complete |
| 41 | M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia orsecuring with clips |
| 42 | Dismantling of fencing wire mesh any type |
| 43 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 44 | Dismantling posts or struts (Wood, Steel or RCC), any section embedded in concrete, brick work etc. including taking out embedded portion and making good disturbed ground. |
| 45 | S&F Posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 |
| 46 | Supply only Chain link MS galvanised fencing, any size or type |
| 47 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire |
| 48 | S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con-forming to Fe 290.Gde-E-165 |
| 49 | S &F framed work as in doors or gates of with tube section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and decorative cast iron artical etc. |
| 50 | S&F 2.00mm thick, Fibre glass reinforced translucent plain sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc including dismantling of old sheets. |
| 51 | M&L for preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide or zink chrome primer on new steel urfaces al as specified. |
| 52 | M&L 40 mm thick for Cement concrete type B-1,1:2:4 (20mm graded aggregate) as in flooring surface finished even and smooth without using etxra cement |
| 53 | M&L for Precast factory Made SFRC (Steel fibre reinforced concrete) manhole cover with frame of following specification for Heavy duty including groove & hook arragement for liftingand placing in position complete all as specified :(a) Clear Opening : 600mmx900mm (b) cover size : 700mmx1000mm (c) thickness of cover : 100mm (d) frame outside diamention : 830mmx1150mm (e) Thickness of Cover frame : 150mm (f) Resting length : 75mm (g) Grade of concreate : M-30 |
| 54 | M&L for Precast factory Made SFRC (Steel fibre reinforced concrete) manhole cover with frame of following specification for Heavy duty including groove & hook arragement for liftingand placing in position complete all as specified(a) Clear Opening : 600x600mm (b) cover size : 700mmx700mm (c) thickness of cover : 100mm (d) frame outside diamention : 820mmx820mm (e) Thickness of Cover frame : 150mm (f) Resting length : 50mm (g) Grade of concreate : M-30 Please Enable Macros to View BoQ information |