| 1 | Replacement of CI/ DI Double flange sluice valves,non return valves,butter fly valves etc. in existing Distribution/Rising Main/Transmission Main pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including providing and fixing MS Nut and Bolt and rubber gasket, dewatering and providing adequate safety arrangement at site and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as Valve, Tail piece, CID Joints etc. shall be provided by Department free of cost) In all type Soil |
| 2 | 80 mm |
| 3 | 100 mm |
| 4 | 125 mm |
| 5 | 150 mm |
| 6 | Restoration of cement concrete road including making of pit in regular shape, ramming and consolidation of surface, laying, positioning and compacting cement concrete ( M-20 ) minimum thickness 200 mm upto the satisfaction of engineer incharge. The rate includes the making of pit in regular shape, all labour, material and T&P charge complete job. |
| 7 | Cleaning of Ground water reservoir ( GLR's) of below mentioned capacity including removal of all silt from reservoir, scrapping of wall, disinfection of reservoir after cleaning and disposal of silt up to 1.00 Km lead and painting the date of cleaning on the reservoir. |
| 8 | 16 to 20 KL |
| 9 | 26 to 30 KL |
| 10 | 31 to 50 KL |
| 11 | 51 to 100 KL |
| 12 | Cleaning of Over Head Service Reservoir ( OHSR ) of below mentioned capacity including removal of all silt from reservoir, scrapping of walls, disinfection of reservoir after cleaning and disposal of silt up to 1.00 Km lead and painting the date of cleaning on the reservoir. |
| 13 | 50 to 100 KL |
| 14 | 201 to 300 KL |
| 15 | 401 to 500 KL |
| 16 | Maintenance of pipelines irrespective of size & material which includes Repairing of Bursts & leakages pollution control, survey & removal of choking, disconnection of illegal connections, Collection & recording minimum 10 nos. residual chlorine samples during daily supply timings, interconnections and all works related to pipeline network in existing distribution /rising main pipe lines of all sizes by digging out suitable size of pit in soft and loose soil/ hard soil including cutting of Black top, WBM & CC top of road of any size at work site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. For entire job contractor will use their own T & P. Contractor with his own resources shall arrange de-watering,JCB & Tractor compressor if any and restore any amenity at his own cost damaged while performing the work in this item. The work includes daily patrolling and repair the leakages within stipulated time and complete maintenance of pipe line network of rising and distribution pipeline network within the scope of work for per km pipe line per month. Jointing material shall be provided by the department. Minimum labour for a following kms pipelines to be deployed. 1 km to 50 km - one fitter-II & one beldar |
| 17 | 51 km to 100 km - one fitter-II & Two beldar (64 KM *12 Months=768 Kms) |
| 18 | Maintenance of tubewells which includes complete repairs / rewinding of submersible pump sets including cost of material components required to repair pumpsets, starters, meters etc. of electric panel of tube wells, Lowering and unlowering of pumpsets complete in all respect, maintenance of Histroy sheet as directed by Engineer-in-charge for tubewell per month. |
| 19 | 8.0 HP to 10.0 HP ( 17 Nos. * 12 Months=204) |
| 20 | 11.0 HP to 12.5 HP (1*12=12 Nos.) |
| 21 | 13.0 HP to 15.0 HP ( 6 Nos. * 12 Months=72) |
| 22 | Maintenance of tubewells which includes round the clock monitoring of tubewells of all sizes, complete repairs / rewinding of submersible pump sets including cost of material components required to repair pumpsets, starters, meters etc. of electric panel of tube wells, Lowering and unlowering of pumpsets complete in all respect, maintenance of log-books & Histroy sheet as directed by Engineer-in-charge for tubewell per month. |
| 23 | 8.0 HP to 10.0 HP (7 Nos.Tubewells *12 Months= 84 Nos. ) |
| 24 | 11.0 HP to 12.5 HP (3*12=36 Nos.) |
| 25 | Daily/ periodical operation of valves at supply times for specified by department per sluice valve per month. (Valve rod and cap to be arranged by contractor) 80-300mm (20 Nos.*12 Months=240 Nos.) |
| 26 | Unlowering of submersible pump set along with lowering pipes with depth up to 120 mtr and submersible cable with safety from tube well, checking the pump set, transportation of pump set from tube well site to store as direction, receiving repaired / new pump set from store/ divisional store , testing the same, transportation to site and lowering back into tube well along with submersible cable, lowering pipes, specials etc and commissioning of the tube well. The job also includes cable jointing, checking of discharge of pump set, interconnection of lowering pipe from nearby distribution pipe line, checking of starter and reporting for completion of Job or fault/problem if any. (Upto 20 Km distance run by lowering machine) For three Phase pump set G.I. Double Flanged Pipe Lowering Assembly of nominal dia 50 mm |
| 27 | Providing, Fabrication of Mild Steel Plane Ended/ Flanged Specials like Tees, Bends, Reducers, Enlargers, Plugs, Tail Pieces and Blank Flange made from MS pipes, MS sheet strip and MS Sheet of required sizes by welding, cutting and treading as per site conditions and as directed by the Engineer- In- Charge complete in all respect. |
| 28 | Supplying of MS Rods and Chuck Nut (Complete Set) for different sizes of sluice valve and should be supplied as according to size of Check Nut including material for the following sizes. |
| 29 | Sluice Valve Size 80mm |
| 30 | Sluice Valve Size 100mm |
| 31 | Sluice Valve Size 125mm |
| 32 | Sluice Valve Size 150mm |
| 33 | Sluice Valve Size 200mm |
| 34 | Making Direct Pump Piece with heavy duty pipes (Class- B) and flange (as per table- D) including cutting of pipe, threading welding and MS strip for length - 100 mm, Width- 20 mm and thickness- 6 mm and to be welded around the strip with pipe and flanged. Hole in the flanged will be standard size and above 15 mm in size. After tightening the pipe and flanged, welding will be done at junctin of flange and pipe complete in all respect including cost of material. The Length of Direct Pump Piece will be 30 cm (300 mm). |
| 35 | 2\\" dia. Size (50 mm) |
| 36 | Making Reducer Pump Piece with heavy duty pipes (Class- B) and flange (as per table- D) including cutting of pipe, threading welding and MS strip for length - 100 mm, Width- 20 mm and thickness- 6 mm and to be welded around the strip with pipe and flanged. Hole in the flange will be standard size and above 15 mm dia. in size. After tightening the pipe and flanged, welding will be done at junctin of flange and pipe complete in all respect including cost of material (Both the larger and smaller pipe will have equal length making reducer). The Total Length of Reducer Pump Piece will be 30 cm (300 mm). |
| 37 | 2x2 ½ “ dia size (50 x 65 mm) |
| 38 | Turning of various sizes of CID Joints Class- 10/ 15 Complete set (Labour Charges), The Joints will be supplied by the Junior Engineer concern of Department and carting to workshop and after turning of these joints, firm is liable to transport upto Junior Engineer concern's store own his cost. |
| 39 | 80 mm dia |
| 40 | 100 mm dia |
| 41 | 125 mm dia |
| 42 | 150 mm dia |
| 43 | Replacement of existing wire mesh on ventilators of GLRs, OHSRs, CWRs etc. with 16 mm dia MS vertical bars placed at 10 cms wherever required, having 16-gauge wire mesh with a inner base of expanded jali welded around with vertical bars |
| 44 | Replacement of existing copper float dia 300 mm and iron counter weight for water level indicator |
| 45 | Providing, fabrication and fixing mainhole cover 600X600 size made of angles 50X50X6 mm frame,40X40X5 mm frame of cover, 6 mm thick MS sheet with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide With lock (minimum weight 50 Kg) |
| 46 | Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 47 | Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish : 20mm thick |
| 48 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar. |
| 49 | P & F Stop Cock (IS :8931 Mark), superior quality & of approved make: Brass 400 gm. 15mm nominal bore. |
| 50 | P & F Push Cock superior quality, of approved make C.P. Brass 15 mm. |
| 51 | Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size : 32mm dia nominal bore |
| 52 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : |
| 53 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: Old work (one or more coats) including scrapping surface and necessary repairs. Same colour Please Enable Macros to View BoQ information |