| 1 | Excavating in post holes(or similar holes) each n.exc 0.5 cum in soft/disintegrated rock, getting out, returning, filling in, watering and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance n.exc 50m and making good surfaces complete all as specified and directed. |
| 2 | M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed. |
| 3 | S&F mild steel work in tubular trusses/framed work including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St.-240 complete all as specified and directed. |
| 4 | S&F mild steel framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gussets plates, riveting, etc. n exc 10 Kg each brackets, conforming to Fe-290. Gde-E-165 complete all as specified and directed . |
| 5 | M&L for preparation of new or previously untreated steel surfaces exceeding 10 cm width or girth and applying two coats of anti corrosive paint over a coat of red oxide primer all as specified and directed. |
| 6 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 7 | S&F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, ridge, hip and vally gutters, fixed with self tapping screws as specified complete all as specified and directed. |
| 8 | M&L for PVC semi circular (half cut) pipe 110 mm dia including stack clamp and other connected items such as bend, Tee etc. to fixed to CGI sheet as in valley gutter for rain water complete all as specified and directed. |
| 9 | M&L for PVC pipe 110 mm dia including stack clamp and other connected items such as bend, Tee, junction etc. as in rain water pipe complete all as specified and directed. |
| 10 | Surface excavation n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/disintegrated rock complete all as specified and directed. |
| 11 | Excavation in trenches in soft/disintegrated rock, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out complete all as specified and as directed. |
| 12 | Returning filling in including spreading levelling, watering and well ramming in layers n.exc 25 cm thick in any type of soil/rock complete all as specified and directed. |
| 13 | Removing excavated material (Soils/rock) to a distance not exceeding 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed. |
| 14 | M & L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed. |
| 15 | M&L for plain cement concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed. |
| 16 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping, benching, cills, sismic and similar other bands etc. including necessary weathering, slightly rounded or chamfered angles and throating and necessary form work complete all as specified and directed. |
| 17 | S&F rolled mild steel in Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections conforming to Fe- 290 (Gde E-165) complete all as specified and directed. |
| 18 | S&F rolled mild steel in roof trusses(framed), trussed purlins, crane gantries, rails and fastenings, MS pipe for post and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe- 290(Gde E-165) complete all as specified and directed. |
| 19 | S&F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe- 290 (Gde E-165) complete all as specified and directed. |
| 20 | S&F rolled mild steel in plates ( plain or chequered ) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 21 | S&F mild steel screw bolts (machine made) dia of shank 11 to 15 mm with hexagonal or square head at one end and screwed the other end or screwed both end, each screw end to be fitted with 3 mm thick MS washers and one hexagonal nuts, length of bolt exc. 5 cm and not exc. 10 cm long complete all as specified and directed. |
| 22 | M&L for RCC M-30 Design mix (using 20 mm graded stone aggregate) as in footing, foundation beams, plinth beams, bases of columns etc. complete all as specified and directed. |
| 23 | Use and waste of form work to flat sides of concrete foundation footing, bases of columns raft and raft beams sides and soffits of foundation and plinth beams and similar work vertical or to batter for rough finish surface of concrete complete all as specified and directed. |
| 24 | M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed. |
| 25 | M&L for mild steel TMT bars 5 mm dia and over in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed. |
| 26 | S&F 0.56 mm thick plain aluminium sheeting Alloy 31000 H4 as in ridges, hips, valley gutters, drips and straight flashing complete all as specified and directed. |
| 27 | M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) 75 mm thick as in sub base or in levelling course, finishing the surface even and rough to receive floor complete all as specified and directed. |
| 28 | M&L for hardcore of broken stone or boulder gauge n.exc. 63 mm deposited, spread & levelled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 29 | M&L for fixing 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 30 | M&L for precast cement concrete block masonry, type C-1 (1:3:6) (20 mm graded aggregate) with solid blocks, exc 10 cm in width and setting in CM 1:6 complete all as specified and as directed. |
| 31 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surface/ block masonary in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 32 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surface/block masonary in cement mortar 1:4 finished even & smooth without using extra cement complete all as specified and directed. |
| 33 | M&L for applying two coats of cement base paint over a coat of alkali resistant primer on new surfaces of walls including preparation of surface complete all as specified and directed. |
| 34 | M&L for 75 mm thick cement concrete type C2 1:3:6 (using 40 mm stone graded crushed stone aggregate) as in plinth protection surface finished even and smooth without using extra cement including forming construction (dummy) joints 6 mm wide & 10 mm deep and filled with filler at an interval not exceeding 3 metre and at change of direction and necessary formwork complete all as specified and directed. |
| 35 | S&F in position PUF (Polyurethane Foam) insulated sandwich roofing sheets of 50-70 mm nominal total thickness, top and bottom facing material comprising of (0.50 mm thick pre-painted galvalunm (PPGL) steel sheet, bounded to a rigid Polyurethane Foam (PUF) core manufactured with CFC and HCFC - free blowing agents. The PUF core shall have a minimum density of 40 + 2 Kg/m3 complete all as directed.Note :- Installation shall be carried out strictly in accordance with the manufacturer’s specifications and as directed at site. MAKE:- JSW/ RINAC India Ltd./ Alpha Roofing/ EPACK Prefab/ Virat Industries/ Prince Composite |
| 36 | M&L for point wiring complete for one light/ fan/ exhaust fan point controlled by one, one way 5/6 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20 mm dia 'medium grade' PVC conduit ISI marked concealed in wall and fittings and modular metal flush box, modular white cover plate with frame, blanking plate and cutting chases in wall/ ceiling incl making good to the disturbed surfaces to match the existing including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and directed.Note- (i) Rates include the cost of blanking plate, modular plate, modular boxes and covers of suitable modules as required at site.(ii) Modular box, plate and cover shall be of same make as of switch//socket/regulator. |
| 37 | All as per item No. 36 above but for one 5 pin 5/6 Amp socket outlet point on an independent board. |
| 38 | All as per Item No 36 above but for one 6 pin 15/16 amps socket outlet point on an independent board with FRLS cables of size 4 Sqmm and green colour earth cable of size 4 Sqmm. |
| 39 | S&F modular type switch one way 6 Amps, 230 Volt, 1 Module complete all as specified and directed. |
| 40 | S&F modular type switch one way 16 Amps, 230 Volt, 1 Module complete all as specified and directed. |
| 41 | S&F modular type socket one way 6 Amps, 2/3 pin, 230 Volt, 2 Module complete all as specified and directed. |
| 42 | S&F modular type socket one way 6/16 Amps, 2/3 pin, 230 Volt, 2 Module complete all as specified and directed. |
| 43 | S&F ceiling rose, two or three terminal, surface bakelite 65 x 50 mm complete all as specified and directed. |
| 44 | S&F modular type fan regulator, electronic step type, 120 W, 2 Module complete all as specified and directed. |
| 45 | S&F MCB single pole 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 46 | S&F MCB tripple pole and neutral(TPN) 415 volts, 'C' curve of rating 10 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 47 | S&F sheet metal enclosure MCB distribution board, double door with IP-43 protection TPN, 415 Volts, 8 way, Vertical type, including suitable size copper bus bar and metal door, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed. |
| 48 | S&F LED tube light fitting surface and wall mounted batten Aluminium body with 22/20 watts LED having minimum 100 lumens/watts and with integrated electronic driver complete all as specified and directed. Make: Philips cat No-BN021CLED22S PSU CW GR/ Crompton cat no-CCS-103-20-65-SL-DP-NWH/ Halonix HLB-03-20-CW-AL-SQ. |
| 49 | S&F brushless direct current (BLDC) ceiling fan 1400 mm sweep with service value 6.00 BEE, 5 star rating complete with blades and other accessories, single phase, 230 V including suitable size GI pipe down rod and making connection with sheathed 3 core cable of size 0.75 Sqmm flexible copper conductor wire complete all as specified and directed. Make : Havells cat No- FHCNF5SWHT56/Orient model Hector 500/ Bajaj Model- ENERGOS 28(SKU Code 251100EE) |
| 50 | S&F LED flood light fitting 120 Watts, IP 66, having pressure die cast aluminium alloy housing with high power LED as lightning source and lens embedded PC cover having top opening seperately including Driver having IP-66 protection, including surge protection device 5 KV and making electrical connection to the fitting with Suitable size of service wire complete as as directed.Make- Orient LFSMU-120-C/ Havells cat no: JETAIRISFL 120WLED 757APWBLTG/ Halonix Cat no: HLFLD-ML25-120-CWL-R. Note :- Connection cable will be measured and paid seperately under respective item |
| 51 | M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron Wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 15 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40 mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl. excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No. 3 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed.Note:- The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M. |
| 52 | S&F Earth continuity GI wire of size 4 mm fixed to wall and batton or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other situation for loop earthing etc. complete all as specified and directed. |
| 53 | S&F sub main wiring (three phase) with four single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 6 Sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 32 mm PVC conduit and fittings concealed in wall/ roof/ floors/ ceiling etc. including cutting chases to walls for laying conduit wherever required and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed.NOTE:- One unit length shall measured as four run of main wire, one run of earth wire and one run of PVC conduit |
| 54 | S&L XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 50 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 55 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in hard/dense soil for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out complete all as specified and as directed. |
| 56 | Supply & laying double walled corrugated (DWC) HDPE full rounded pipe conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 50 mm inner dia and 63 mm outer dia complete all as directed. |
| 57 | Supply and installing, testing, commissioning split AC unit indoor/outdoor, with cordless remote control unit and inbuilt air iodiser and plasma filter for better indoor air quality, minimum 5 star rating and ISEER rating of 3.75, 1.5 TR capacity with copper tubing condenser, low noise with 230 Volt range, LED display, anti-dust, antimicrobial protection, anti-corrosive coating, self diagnosis with all necessary fixing arrangements such as brackets etc. complete all as specified and directed.Make : Voltas Modal SAC185V VECTRA ELITE/ Blue star Model IC518 DNU/ LG US-Q24ENXENote:- Extra copper tubing, water pipe, voltage Stabilizer etc. required to complete the installation will be measured and paid separately under respective items herein after. |
| 58 | S&F Voltage stabilizer 5 KVA capacity, single phase, naturally Air Cooled indoor type and designed for input variation between 130 V to 280 V with output voltage stabilized at 230 V with accuracy of + 2.5 % complete all as specified and directed. Make: V-Guard/MicroTek/Luminous |
| 59 | S&F sheet metal enclosures, single pole and neutral with a two pin and earth plug and socket, plug top and one single pole MCB 20 Amps, C series 240 V complete all as specified and directed. |
| 60 | S&F sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 Sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 32 mm PVC casing caping and fittings fixed on wall/ roof/ floors/ ceiling etc. including cutting chases to walls for laying casing caping wherever required and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed.NOTE:- One unit length shall measured as two run of main wire, one run of earth wire and one run of casing caping. |
| 61 | S&F insulation for copper tubes of split type AC units, insulation type superlon of size 3/8\\" diameter all as directed. |
| 62 | S&F insulation for copper tubes of split type AC units, insulation type superlon of size 5/8\\" diameter all as directed. |
| 63 | S&F copper tubing soft grade suitable for split type AC suction /discharge line of size 5/8\\" diameter all as directed. |
| 64 | S&F copper tubing soft grade suitable for split type AC suction /discharge line of size 3/8\\" diameter all as directed. |
| 65 | Supply and fix 20 mm dia PVC flexible drain pipe heavy duty with necessary fittings for Split AC's complete all as directed. |
| 66 | S&F MCB SPN 240 volts, 'C' curve of rating 40-63 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 67 | S&F sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 10 Sqmm nominal cross sectional area and one run of 10 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 32 mm PVC casing caping and fittings fixed on wall/ roof/ floors/ ceiling etc. including cutting chases to walls wherever required for laying casing caping wherever required and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed.NOTE:- One unit length shall measured as two run of main wire, one run of earth wire and one run of casing caping. |
| 68 | S&F sheet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 8 way, including suitable size copper bus bar and metal door, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed. Please Enable Macros to View BoQ information |