Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | NOTE:-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.(ii) It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer. (iii) (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH'A' before entry/quoting the rates. |
| 2 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed. |
| 3 | Excavating over area not exceeding 1.50 m depth for foundation and getting out soft/loose soil complete all as specified and as directed. |
| 4 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundations or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10Sqm on plan and not exceeding 1.50m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 5 | Excavation in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50m and making good disturbed surface in any type of soil complete all as specified and as directed. |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm on soft/loose soil complete all as specified and as directed. |
| 7 | Removing excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 8 | Material and labour for hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 9 | Material and labour for providing cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concreting complete all as specified and as directed. |
| 10 | Material and labour for providing cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concreting complete all as specified and as directed. |
| 11 | Material and labour for PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary use and waste of formwork complete all as specified and as directed. |
| 12 | Material and labour for providing 40mm thick cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in damp proofing course(DPC) to horrizontal or vertical surface including necessary formwork and mixing of waterproofing compound as per manufacturer's specification complete all as specified and as directed.Note: Waterproofing compound shall be measured and paid seperately under respective item. |
| 13 | Material and labour for reinforced cement concrete 1:2:4 type B1 (Nominal Mix) (using 20mm graded stone aggregate) as in beams, cantilevers, lintel over 1.50m span complete all as specified and as directed. |
| 14 | Material and labour for reinforced cement concrete 1:2:4 type B1 (Nominal Mix) (using 20mm graded stone aggregate) as in footing, foundation beam, bases of column plinth beams, etc complete all as specified and as directed. |
| 15 | Material and labour for reinforced cement concrete 1:2:4 type B1 (Nominal Mix) (using 20mm graded stone aggregate) as in as in column, pillars, piers, posts and struts complete all as specified and as directed. |
| 16 | Material and labour for reinforced cement concrete 1:2:4 type B1 (Nominal Mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roof landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 17 | Material and labour for reinforced cement concrete 1:2:4 type B1 (Nominal Mix) (using 20mm graded stone aggregate) as in vertical / retaining wall complete all as specified and as directed. |
| 18 | Material and labour for reinforced cement concrete 1:2:4 type B1 (Nominal Mix) (using 20mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 19 | Material and labour for providing precast cement concrete (1:1½:3), type B-1, (using 20mm graded aggregate) as in landings, cover slabs(for manholes, etc.), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar (1:4) including necessary use and waste of form work complete all as specified and directed.Note: Reinforcement shall be measured and paid seperately under respective item. |
| 20 | Material and labour for 100mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base floring and finish the surface fair and even complete all as specified and as directed. |
| 21 | Material and labour for 75mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base floring and finish the surface fair and even complete all as specified and as directed. |
| 22 | Material and labour for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, paving, footpath etc and finished the surface even and smooth without using extra cement laid in panels including joint filled with sealing compound complete all as specified and as directed. |
| 23 | Material and labour for 25mm thick PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in sub base floring and finish the surface fair and even complete all as specified and as directed. |
| 24 | Material and labour for Providing precast cement concrete (1:2:4), type B-1, (using 20mm graded aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified and as directed. |
| 25 | Material and labour required extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed. |
| 26 | Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 27 | Materials and labour for half brick thick brick work with sub class 'B' bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed. |
| 28 | Materials and labour for use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bres-summers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished flat surfaces of concrete complete all as specified and as directed. |
| 29 | Material and labour for use and waste of formwork to chullah hoods, chajjas, trough and similar items including edges, fair finished flat surface complete all as specified and as directed |
| 30 | Material and labour for flat formwork to soffits of suppended slab such as roof slabs, floor slab, landings and similar works, not exceeding 200mm thick with rough finished flat surface complete all as specified and as directed. |
| 31 | Material and labour for flat formwork to soffits of suppended slab such as roof slabs, floor slab, landings and similar works,exceeding 200mm thick with rough finished flat surface complete all as specified and as directed. |
| 32 | Material and labour for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter with rough finished flat surface complete all as specified and as directed. |
| 33 | Material and labour for flat formwork to sides of pillars,posts,struts,piers,columns and stanchions with rough finished flat surface complete all as specified and as directed. |
| 34 | Material and labour for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings,openings in concrete walls, floor and roofs not exceeding 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide complete all as specified and as directed. |
| 35 | Material and labour for mild steel TMT bars 10mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed. |
| 36 | Material and labour for mild steel TMT bars 5mm dia and over and upto and including 10mm dia, cut to length bent to shape required, including cranking bending spirally for hooping for stirrups, spacers, binders and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed. |
| 37 | Material and labour for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing, conforming to Fe 410 W (Gde-E-250) quality A complete all as specified and as directed. |
| 38 | Supply and fixing steel work in tubular trusses i.e truss bottom, top bend, sides, side supports, holding plates, posts and base plate etc. including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St-240 etc complete all as specified and as directed. |
| 39 | Materials and labour for mild steel fencing posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 40 | Material & Labour for Mild steel screw bolts 5mm to 10mm dia of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5cm and not exceeding 10cm long complete all as specified and as directed. |
| 41 | Fixing only Chain link fencing 4mm dia galvanised steel wire,100x100mm mesh, made up into mattresses or cages, lapped, wired and laid/fixed in position, including line wires, any mesh, any size,any type of standards rails straining bolts etc including provisioning of binding wires complete all as specified and directed. |
| 42 | Supply only Chain link fencing 4mm dia GI wire netting having mesh size of 100x100mm, made up into mattresses or cages, lapped, wired and laid/fixed in position complete all as specified and directed. |
| 43 | Supply and fixing galvanised. 2 strand, steel barbed wire 2.24mm dia. barbed with 2mm dia. barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as in repair complete all as specified and as directed. |
| 44 | Supply and fix Concertina coil razor tape barbed wire (reinforced barbed tape) of the following specifications complete all as specified and as directed :- (i) Dia of coil when unstretched -600 mm(ii) No of circles- 50 to 53 per coil(iii) Weight of each coil -8.62 to 10 Kg(iv) Coverage per coil- 6 RM.(v) Central Core Wire:- Made from high tensile spring steel core wire conformning to IS-4454 duly hot dipped galvanised (conforming to IS 2629) with diameter 2.59 mm ± 0.05 mm, UTS 162 Kg/Sqmm, Zinc coating 230 gms /Per Sqm.(vi) Strip :- Electro galvanised steel strip 0.5mm ± 0,02 mm thick, width 19 mm (before wrapping on central core wire), conforming to IS-1573, Zinc coating - 120 gm/Sqm, width of barbs 11.5 mm, pitch of barbs 25.4 mm ± 0.2 mm.(vi) Clips:-Galvanised - 1.5 mm thick U clips, \\"U\\" clips special type for joining one coil to another coil and PBT(R) wire to PBT(R) wire joining and the strengthening wire (two line wires for each run)fixed to angle iron post with box clips, nuts and bolts.(vii) No of clips 105 for each coil, handle and spikes to be provided as required. |
| 45 | Material and labour for 1.25 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including, steel gates and similar work, cut size, holes punched; including round headed screws, and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded , including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 46 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 47 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 48 | Supply and fixing Anodised powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators etc with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 49 | Supply and fixing Anodised powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21, 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed. |
| 50 | Supply and fixing 4.00 mm thick frosted glass, ordinary quality and glazing in square not exceeding 0.5 sqm in each pane fixed to aluminium frame window/ventilator complete all as specified and as directed. |
| 51 | Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. |
| 52 | Supply and fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded decorative coloured laminates PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and decorative coloured laminates PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail or bottom rail ; panelling of decorative coloured laminates PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC laminated sheet beeding, and joined together with solvent cement, supplying and fixing in the frame at the site as per specification complete all as specified and as directed. |
| 53 | Supply and fixing 150mm size PVC handle complete all as specified and as directed. |
| 54 | Supply and fixing 100mm size PVC butt hinges, for PVC door complete all as specified and as directed. |
| 55 | Supply and fixing PVC barrel tower bolts, 150mm long complete all as specified and as directed. |
| 56 | Material and labour for non skid ceramic coloured tiles (Premium Quality) 7 to 8mm thick (Square/ rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm coloured in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 57 | Material and labour for non skid ceramic coloured tiles (Premium Quality) 7 to 8mm thick (Square/ rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm coloured in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 58 | Material and labour for glazed ceramic coloured tiles (Premium Quality) of size 350x250x7mm/ 450x350x 7mm thick as on vertical surfaces, set and jointed in neat cement slurry and pointed in white cement with pigment to match with the shade of tiles laid over and including 10mm thick cement plaster in CM (1:4) complete all as specified and as directed. |
| 59 | Material and labour for precast Cement Concrete chequered tiles of size 200 x 200 x 25mm thick as in floor, set and jointed in neat cement slurry and pointed with cement laid over and including 20mm thick screed bed in CM (1:4) complete all as specified and as directed. |
| 60 | Material and labour for machine pressed precast cement concrete interlocking paver blocks 60mm thick and M 35 Grade confirming to IS-15658-2006 and laid over and including 25mm thick sand cushioning complete all as specified and as directed. |
| 61 | Material and labour for Granite work (of any type) 20 mm thick (table rubbed and polished) in slab, jambs, platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with granite shade complete all as specified and as directed. |
| 62 | Materials and labour for 15 mm thick rendering on brick work in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 63 | Materials and labour for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) with using water proofing coumpound and as per manufacturer specification and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.Note : WPC will be measured and paid separately. |
| 64 | Materials and labour for 10 mm thick rendering on concrete surfaces in ceiling in cement mortar (1:3) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 65 | Supply only liquid integral water proofing compound conforming to IS-2645 complete all as specified and directed. |
| 66 | Materials and labour for 15 mm thick screed bed on concrete surface in cement mortar (1:6) and finished the surfaces fair and even complete all as specified and as directed. |
| 67 | Material and labour for water proofing treatment to RCC roof slab incl parapet comprising with the following course of treatment/specifications from bottom to top :- (a) Applying bituminous primer @ 200-300 gm per Sqm over plastered surfaces of roof including parapet surfaces. (b) One layer of APP based polymeric membrane of approved manufacturer, 3mm thick, weight not less than 3.60 kgs per sqm, reinforced with non woven polyester fabric or weight not less than 150 grm per sqm. Polymeric membrane shall taken to a height 60 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. Note: (i) Laying of APP based polymeric membrane shall be done by torch on method or as per manufacturers instructions. (ii) A minimum overlap of 100mm and 75mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instructions. (c) Applying two coats of bituminous aluminum paint on top of APP membrane. |
| 68 | Materials and labour for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed. |
| 69 | Materials and labour for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 70 | Material and labour for applying two coats of cement base paint over a coat of primer including preparation of newly plastered surfaces of wall complete all as specified and as directed. |
| 71 | Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 72 | Material and labour for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, brick work walls and roof slab in M-25 including beams etc with vent shaft, manhole openings with cover connection etc, as per TD Drg for 10 users complete all as specified and as directed. |
| 73 | Material and labour for soakage well (1.8 M dia × 3.0 M effective depth) excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete made of brick masonry in CM, RCC cover slab in M-25 / SFRC cover, interconnecting pipes of RCC/DWC filled with brick bats as per TD Drg for 10 users complete all as specified and as directed. |
| 74 | Cutting of CI/GI/DI pipes specials and reducing to required length in position for insertion of new tees, tail pices, branches etc 100 x 100 x 25mm bore dia CI pipe line complete all as specified and as directed. |
| 75 | Material and labour for PCC 1:3:6, type C2, (using 40mm graded stone aggregate) as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 150mm bore of pipe complete all as specified and as directed.Note: Reinforced concrete pipes shall be measured and paid seperately. |
| 76 | Material and labour for 150mm bore Reinforced concrete pipes, class NP3, laid and jointed with collars, laid in trenches on concrete bed to required slope complete all as specified and as directed.Note: Earthwork and concrete bed shall be measured and paid seperately. |
| 77 | Supply and laying 25mm bore galvanised steel water tubing medium grade including all fittings and laid in trenches complete all as specified and as direcetd. |
| 78 | Supply and fix 20mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and as direcetd. |
| 79 | Supply and fix 15mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and as direcetd. |
| 80 | Supply and fixing 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 81 | Supply and fixing 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 82 | Supply and fixing 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with suitable size of MS flat iron clamp complete all as specified and as directed. |
| 83 | Supply and fixing 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 84 | Supply and fixing 110mm bore PVC (SWR) junction single, (Single T) equal or unequal, with oval access door complete all as specified and as directed. |
| 85 | Supply and fixing 110 mm bore PVC (SWR) vent cowl complete all as specified and as directed. |
| 86 | Supply and fixing 75mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 87 | Supply and fixing 125/110 mm dia, PVC (SWR) gully trap, including jointing with solvent cement complete all as specified and as directed. |
| 88 | Supply and fixing Vitreous China squatting pan of ‘Orissa pattern’, size 580 mm x 440mm (white) with ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern complete including provision of PCC bedding and connection to trap, flushing pipe, antisyphonage pipe, etc. including making good the disturbed floor complete all as specified and as directed. |
| 89 | Supply and fixing Vitreous China urinals half stall type of size 460mm x 330mm x 250mm (minimum) with urinal spreader, grating and union for discharge pipe, 15mm dia PVC connection pipe 450mm long, CP waste coupling, 40mm dia waste pipe 600mm long high density polyethylene(HDPE) pipes of pressure rating 6 kgf/sq.cm complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinals to plugs with and including 60mm long brass screws, pointing around urinals back in cement complete all as specified and as directed. |
| 90 | Supply and fixing vitreoues china WHB, white, flat back, of size 550X400mm including CP brackets, CP waste coupling 32 mm bore, PVC waste pipe 32mm dia with and including 15mm bore PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and as directed. |
| 91 | Supply and fixing looking mirror of size 600mm x 450mm x 5mm thick bevelled edge of selected quality glass, decorative type mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 92 | Supply and fixing 10 litre capacity low level PVC flushing cistern (White colour), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete all as specified and as directed. |
| 93 | Supply and fixing 15mm bore fancy type bib taps cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed to pipe complete all as specified and as directed. |
| 94 | Supply and fixing 15mm bore fancy type angular stop cock made of brass chromium plated screwed both ends for pipe with crutch handle, screwed down, screwed for iron pipe complete all as specified and as directed. |
| 95 | Supply and fixing 15mm bore Chromium Plated pillar tap fancy type cast copper alloy, with capstan heads screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for pipe complete all as specified and as directed. |
| 96 | Supply and fixing soap dish holder chromium plated of approximate size 200x 200x90mm fixed to plugs with chromium plated brass screws complete all as specified and as directed. |
| 97 | Supply and fixing tubular towel rail brass chromium plated, 20mm dia, D type, 60cm long fixed with two plugs (gutties) of 2nd class hard wood embedded in CM 1:3 with screws complete all as specified and as directed. |
| 98 | Supply and fixing 25mm bore Gun metal Globe or gate valve with iron wheel head and gun metal spindle screwed both ends complete all as specified and as directed. |
| 99 | Material and labour for (concealed Type) point wiring including necessary chase cutting of wall for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit medium grade with all accessories and sunk modular GI box for mounting of fittings like switch, socket and fan regulator and making good the disturbed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge.Note: A. Red colored cable shall be used for live connection; black colored cable shall be used for neutral connection and green colored cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.B. The Rate of point wiring includes the following: - (i) Copper standard wire. (ii) PVC conduit with accessories. (iii) Chase cutting. |
| 100 | . -Ditto- all as per item No 98.00 here-in-before but for 3 pin 6 amps switch socket combination on the same board with 1.5 Sqmm cable and -ditto-. |
| 101 | . -Ditto- all as per item No 98.00 here-in-before but for 3 pin 6 amps switch socket combination on the independent board with 1.5 Sqmm cable and -ditto-. |
| 102 | . -Ditto- all as per item No 98.00 here-in-before but for one 6 pin multi, Modular socket outlet, 6/16 Amps, independent, with single core multi strand insulated unsheathed copper conductor 4.00 Sqmm FRLSH of size including single core multi strand unsheathed copper conductor 4.00 Sqmm FRLSH for earth continuity and connecting to common earth dolly and -ditto-. |
| 103 | Supply and fixing Metal flush box modular for 3 module complete all as specified and as directed. |
| 104 | Supply and fixing Metal flush box modular for 6 module complete all as specified and as directed. |
| 105 | Supply and fixing White cover plate with frame (both inner plate & outer plate cover),modular for 3 module complete all as specified and as directed. |
| 106 | Supply and fixing White cover plate with frame (both inner plate & outer plate cover),modular for 6 module complete all as specified and as directed. |
| 107 | Supply and fixing Modular type shuttered socket outlet 2/3 pin, 6 Amps, 230 volt, 2 Module complete all as specified and as directed. |
| 108 | Supply and fixing Modular type shuttered socket outlet 2/3 pin, 6/16 Amps, 230 volt, 2 Module complete all as specified and as directed. |
| 109 | Supply and fixing for switch socket combination multipurpose 2 in 1, 5 pin 6/16 amps 230 volt flush type complete all as specified and as directed. |
| 110 | Supply and fixing Modular switch single pole one way 6 Amps, 230 volt, 1 Module complete all as specified and as directed. |
| 111 | Supply and fixing Modular switch single pole one way 16 Amps, 230 volt, 1 Module complete all as specified and as directed. |
| 112 | Supply and fixing Piano switch flush button single pole one way 5/6 Amps, 240 volt complete all as specified and as directed. |
| 113 | Supply and fixing Modular type 5 step fan regulator 120 watt step type, AC 220 Volt, 2 Module complete all as specified and as directed. |
| 114 | Supply and fixing ceiling rose surface Bakelite three terminal complete all as specified and as directed. |
| 115 | Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. minimum air delivery 210 CFM with service value 6.00 BEE. Five stars rated (Current Year) with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 116 | Supply and fixing Exhaust fan steel body AC single phase 230 V of size 300 mm sweep with blades, frame & louvers including necessary hole for insertion of exhaust fan all as specified and directed.Note:– (i)The item rate is inclusive of making holes or making existing opening suitable for the installation of exhaust fan as per site condition all as specified and directed by Engr-in-chrg.(ii) The louvers for the exhaust fan shall be made of GI sheet suitable and properly fixed to the opening. |
| 117 | Supply and fixing MCB DB SPN 4 ways double door including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.Note:- MCB SPN and MCB SP shall be measured and paid seperately under respective item. |
| 118 | Supply and fixing MCB SPN, 240 Volts, of 32 amps current rating, 10 KA breaking capacity ‘C' series complete all as specified and as directed. |
| 119 | Supply and fixing MCB SP, 240 Volts, of 6-32 amps current rating, 10 KA breaking capacity ‘C' series complete all as specified and as directed. |
| 120 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 6 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 6 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through 20 mm conduit/ Casing Caping with all accessories and PVC rectangular boxes for mounting switch socket and fan regulator etc complete all as specified and as directed.Note : Three runs of 6 Sqmm cable and conduit shall be measured as one unit. |
| 121 | Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 122 | Supply and fixing Compact street lighting luminaires with deep drawn housing for single 35 Watt LED, 5700K with toughened glass protection, pressure die cast aluminium housing IP66,with epoxy white powder coated and fixing bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length 1.2 mtr,fixed over the vertical wall through two numbers mild steel clamp of 25mm width, 3mm thick MS flat strip and four Nos nuts, bolts & washers of 12mm dia, 150mm long grouted into wall complete all as specified and as directed. |
| 123 | Supply and fixing Compact street lighting luminaires with deep drawn housing for single 70 Watt LED, 5700K with toughened glass protection, pressure die cast aluminium housing IP66,with epoxy white powder coated and fixing bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length 1.2 mtr,fixed over the vertical wall through two numbers mild steel clamp of 25mm width, 3mm thick MS flat strip and four Nos nuts, bolts & washers of 12mm dia, 150mm long grouted into wall complete all as specified and as directed. |
| 124 | Supply and fixing 20 Watt LED post top (white colour), 230 volt, 360 degree made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP65 protection including fixing with LED driver and lamp complete all as specified and as directed. |
| 125 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 126 | Supply and laying GI tubing 40mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables complete all as specified and as directed. |
| 127 | Material and labour for HDPE pipe of pressure rating 10 kgf/cm² and dia 25 mm for passing of cable through PCC foundation from trench to distribution board with necessary clamp nuts and bolts complete all as specified and as directed. |
| 128 | Labour only for boring of hole under roads with mechanical arrangement upto 50 mm dia without disturbing the top surface of the road for passing the cable across the road complete all as specified and as directed. |
| 129 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 25 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. complete all as specified and as directed. |
| 130 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 25 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. complete all as specified and as directed. |
| 131 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 16 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. complete all as specified and as directed. |
| 132 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 10 Sqmm 2 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. complete all as specified and as directed. |
| 133 | Supplying, laying, PVC insulated flat twin-core copper conductor cable of size 2.5 sqmm, including PVC conduit, saddles/clamps, nut-bolts, screws, glands, lugs, and all other necessary accessories, complete in all respects, suitable for street light wiring/connection, including making all required terminations and connections as per site requirement, relevant IS standards complete all as specified and as directed. |
| 134 | Material and labour for LT 1.1 KV (Earthed) grade heat shrinkable end termination jointing kit indoor type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 to 35 sqmm complete all as specified and as directed. |
| 135 | Supply and fixing steel tubular swaged poles, type 410 SP 31 (Overall length 9.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, painting black & white alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified and as directed.Note: Excavation and earth work and PCC shall be measured and paid separately under respective items. |
| 136 | Supply and fixing of cable entry terminal box for street light made of PVC of size 155 × 210 × 92 mm, IP 55/65 degree of protection, brackets provided inside to facilitate DIN rail along with cable entry, including bracket for mounting, including necessary DIN channel fixed and connection including RYB N terminal complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 137 | Supply and fixing of cable entry terminal box for street light made of PVC of size 155 × 210 × 92 mm, IP 55/65 degree of protection, brackets provided inside to facilitate DIN rail along with cable entry, including bracket for mounting, including necessary DIN channel fixed and connection including RYB N terminal complete all as specified and as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail