| Sl. No. | Item Description |
| 1 | A) Supply Part |
| 2 | 11/0.4 kV 630 kVA sub-station with O/D Distribution transformer |
| 3 | Distribution Transformer (Outdoor Type) , 11/0.4 kV, 630 KVA |
| 4 | Steel Tubular Poles (10 meter) |
| 5 | Muffs with concerete filling |
| 6 | ACSR Conductor 6/1/3.35, 50 sq. mm for earthing , jumpering & Bus bar etc. Along with 70 m one span from existing line |
| 7 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 4 Nos] |
| 8 | MS Angle Iron (50X50x6 mm), Length: 2800 mm for four pole structure and bus bar etc. |
| 9 | X-Arm: [Channel Iron (75x40x6mm), Length : 2800 mm X 6 Nos] for supporting DO fuse unit , CT-PT Unit & GO switch |
| 10 | Transformer Belting & Knee Bracing |
| 11 | X-Arm [Channel Iron (100x50x6 mm), Length : 2800 mm x 2 Nos for Transformer Bed |
| 12 | X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer |
| 13 | X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of CT/PT Unit |
| 14 | MS Angle Iron (50X50x6 mm), Length : 2800 mm x 2 Nos |
| 15 | MS Angle Iron 35x35x5 mm), Length : 460 mm x 2 Nos |
| 16 | MS Angle Iron 50x50x6 mm), Length : 950 mm x 2 Nos for Bed Knee Bracing |
| 17 | Transformer LT Distribution Box and GO Switch fixing Assembly |
| 18 | MS Angle Iron (50X50x6 mm), Length : 2800 mm x 2 Nos |
| 19 | MS Angle Iron (50X50x6 mm), Length : 450 mm x 1 Nos |
| 20 | GO Switch Handle supporting : [ Channel Iron (75x40x6 mm), Length:460 mm |
| 21 | GO AB Switch Unit (11kV,1000A) ( Isolator Type) |
| 22 | D.O Fuse Unit |
| 23 | Surge Arrester, 9 kV Station Class (Porcelain Type) |
| 24 | Discs insulator sets (comprising 1 No. Disc: ^^(Polymeric, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 25 | Stay set complete |
| 26 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 27 | Pipe Earthing Set |
| 28 | Pin Insulator 11 kV (polymeric type) |
| 29 | LT Distribution Panel Box with MCCB for 630 kVA DTR (provided by HPSEBL) |
| 30 | Half Clamp (M.S. Flat 50X6 mm) |
| 31 | Full Clamp ( M.S Flat 50x6 mm) |
| 32 | Stay Clamp |
| 33 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 34 | Aluminium Thimble |
| 35 | Copper Thimble |
| 36 | Danger Plate |
| 37 | Barbed Wire |
| 38 | LT Cable (3.5 Core) 500 mm² |
| 39 | LT Cable (PVC) 3.5 core 300 sq. Mm from LT panel Box to EV Charging Panel Box length up to 40 m x 2 |
| 40 | Aluminium Paint. |
| 41 | Red Oxide Paint |
| 42 | Kit Kat 500 Amp for section |
| 43 | LT Switched Capacitors for 630 KVA DTR (216 kVAr) |
| 44 | Transportation of Material Central store to site road |
| 45 | Manual carriage of Material from road to site of work |
| 46 | CT-PT Unit arrangement along with metering for 630 kVA S/stn |
| 47 | Three Phase CT-PT Combined Unit 11 kV/110 V, 100/5A, accuracy class 0.5 s |
| 48 | Energy Meter (3-Phase, 4-Wire) DLMS compliant 400 A CT Type for 630 KVA Transformer ( C-Type) (provided by HPSEBL) |
| 49 | i) Multi Strand Copper Cable for CT-PT and Meter Connection 10C, 2.5 sq mm |
| 50 | ii) 1 inch dia GI pipe for concealin |
| 51 | iii) bend joints/ elbow |
| 52 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 53 | X-arm Channel Iron (75x40x6 mm): Length 2800mmx2 nos.) for supporting main channel for CT-PT Unit |
| 54 | CT-PT Unit Belting and knee Bracing a) M.S Angle Iron (50x50x6 mm), Length 2800mmx4 Nos. |
| 55 | CT-PT Unit Belting and knee Bracing a) M.S Angle Iron (35x35x6 mm), Length 2800mmx2 Nos. |
| 56 | Half Clamp (M.S. Flat 50X6 mm) |
| 57 | Full Clamps (M.S. Flat 50X6 mm) |
| 58 | 11/0.4 kV 250 kVA sub-station with O/D distribution transformer |
| 59 | Distribution Transformer (Outdoor Type) , 11/0.4 kV, 250 KVA |
| 60 | Steel Tubular Poles (10 m) |
| 61 | Muffs with concerete filling |
| 62 | ACSR Conductor 6/1/3.35, 50 sq. mm for earthing , jumpering & Bus bar etc. Along with 70 m one span from existing line |
| 63 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 4 Nos] |
| 64 | MS Angle Iron (50X50x6 mm), Length: 2800 mm for four pole structure and bus bar etc. |
| 65 | X-Arm: [Channel Iron (75x40x6mm), Length : 2800 mm X 6 Nos] for supporting DO fuse unit , CT-PT Unit & GO switch |
| 66 | Transformer Belting & Knee Bracing |
| 67 | X-Arm [Channel Iron (100x50x6 mm), Length : 2800 mm x 2 Nos for Transformer Bed |
| 68 | X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer |
| 69 | X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of CT/PT Unit |
| 70 | MS Angle Iron (50X50x6 mm), Length : 2800 mm x 2 Nos |
| 71 | MS Angle Iron 35x35x5 mm), Length : 460 mm x 2 Nos |
| 72 | MS Angle Iron 50x50x6 mm), Length : 950 mm x 2 Nos for Bed Knee Bracing |
| 73 | Transformer LT Distribution Box and GO Switch fixing Assembly |
| 74 | MS Angle Iron (50X50x6 mm), Length : 2800 mm x 2 Nos |
| 75 | MS Angle Iron (50X50x6 mm), Length : 450 mm x 1 Nos |
| 76 | GO Switch Handle supporting : [ Channel Iron (75x40x6 mm), Length:460 mm |
| 77 | GO AB Switch Unit (11kV,600A) ( Isolator Type) |
| 78 | D.O Fuse Unit |
| 79 | Surge Arrester, 9 kV Station Class (Porcelain Type) |
| 80 | Discs insulator sets (comprising 1 No. Disc: ^^(Polylmaric, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 81 | Stay set complete |
| 82 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 83 | Pipe Earthing Set |
| 84 | Pin Insulator 11 kV (polymeric type) |
| 85 | LT Distribution Panel Box with MCCB for 250 kVA DTR (Provided by HPSEBL) |
| 86 | Half Clamp (M.S. Flat 50X6 mm) |
| 87 | Full Clamp ( M.S Flat 50x6 mm) |
| 88 | Stay Clamp |
| 89 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 90 | Aluminium Thimble |
| 91 | Copper Thimble |
| 92 | Danger Plate |
| 93 | Barbed Wire |
| 94 | LT Cable (3.5 Core) 300 mm² |
| 95 | LT Cable (PVC) 3.5 core 240 sq. Mm from LT panel Box to EV Charging Panel Box length up to 30 m x 2 |
| 96 | Aluminium Paint. |
| 97 | Red Oxide Paint |
| 98 | Kit Kat 500 Amp for section |
| 99 | LT Switched Capacitors for 250KVA DTR (81 kVAr) |
| 100 | Transportation of Material Central store to site road |
| 101 | Manual carriage of Material from road to site of work |
| 102 | CT-PT Unit arrangement along with metering for 250 kVA S/stn |
| 103 | Three Phase CT-PT Combined Unit 11 kV/110 V, 50/5A, accuracy class 0.5 s |
| 104 | Energy Meter (3-Phase, 4-Wire) DLMS compliant 400 A CT Type for 250 KVA Transformer ( C-Type) (provided by HPSEBL) |
| 105 | i) Multi Strand Copper Cable for CT-PT and Meter Connection 10C, 2.5 sq mm |
| 106 | ii) 1 inch dia GI pipe for concealin |
| 107 | iii) bend joints/ elbow |
| 108 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 109 | X-arm Channel Iron (75x40x6 mm): Length 2800mmx2 nos.) for supporting main channel for CT-PT Unit |
| 110 | CT-PT Unit Belting and knee Bracing a) M.S Angle Iron (50x50x6 mm), Length 2800mmx4 Nos. |
| 111 | CT-PT Unit Belting and knee Bracing a) M.S Angle Iron (35x35x6 mm), Length 2800mmx2 Nos. |
| 112 | Half Clamp (M.S. Flat 50X6 mm) |
| 113 | Full Clamps (M.S. Flat 50X6 mm) |
| 114 | Bifurcation of new 11 kV Feeder from 33/11 kV Sub-station Chamba to Baloo- 11 kV HT Line on Steel Tubular poles-2.915 km |
| 115 | Providing Steel Tubular Poles 9 Mtr. Long |
| 116 | Providing Steel Tubular Poles 10 Mtr. long |
| 117 | Muffs with concrete filling |
| 118 | Prov. ACSR 6/1/3.35 mm [{ includes 3 conductor length for 3 ph and additional 3 % ( sag., jumpering and wastage) |
| 119 | Prov. 11 kV Disc Insulator complete set including dead end clamps etc |
| 120 | Prov. 11 kV Pin Insulator (3 No. per Single pole structure and 3 No. per Double Pole structure) |
| 121 | X-Arm (C.I. 2340x100x50x6 mm) i/c tolerance of 100 mm either side |
| 122 | X-Arm (C.I. 1270x100x50x6 mm) i/c tolerance of 100 mm either side |
| 123 | X-Arm (C.I. 1800x100x50x6 mm) i/c tolerance of 100 mm either side |
| 124 | X-Arm (C.I. 2340x75x40x6 mm) i/c tolerance of 100 mm either side |
| 125 | M.S A.I 50x50x6 Length 1800 mmx2 No. belt set |
| 126 | A.I. Knee Bracing set 2(750x50x50x6mm) |
| 127 | A.I Cross Bracing Set complete |
| 128 | Pole Top Bracket [MSCI 100x50x6 mm-100 mm}] |
| 129 | Stay set complete (1 No. for Single Pole, 5 Nos. for Double Pole structure) |
| 130 | Egg Ins. |
| 131 | Stay Wire (10 kg per set) |
| 132 | GO AB Switch Unit (11kV 400 A, 25 KA) |
| 133 | Earthing set H.T complete in all respect |
| 134 | Single Continuous earth wire ( GI, 8SWG) |
| 135 | MS Angle Iron 50x50x6 Length 2400 mm for guarding Angle |
| 136 | Eye Hook |
| 137 | Earth wire clamp |
| 138 | Barbed Wire |
| 139 | Half clamp |
| 140 | Full clamp |
| 141 | Stay clamp |
| 142 | Prov. Danger Plate |
| 143 | Prov. Nut & Bolts off sizes |
| 144 | Prov. Aluminium paint |
| 145 | Prov. Red Oxide Paint |
| 146 | Transportation of Material Central store to site road |
| 147 | Manual carriage of Material from road to site of work |
| 148 | Augmentation of 33/11 kV , 2.5 MVA Sub-Station( Damaged ) to 3.15 MVA Sub station in 33/11KV 2X10 MVA S/Stn Chamba |
| 149 | Power Transformer (3.15 MVA, 33/11 kV, ONAN, OLTC,Outdoor) |
| 150 | 33 kV Switchgear & Allied Equipment: with 01 No., 33kV Incomer |
| 151 | 33 kV Control and Relay (CR) Panel (with Numeric Differential Relay, IEC 61850) |
| 152 | 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type) |
| 153 | 33 kV Isolator (1250 A, 25kA, with Earth Switch) with structure |
| 154 | 33 kV Isolator (1250 A, 25kA, without Earth Switch) with structure |
| 155 | 33 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO,Porcelain) |
| 156 | 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core,Outdoor) (1 No. per Φ) (600/300/1-1) |
| 157 | 33 kV Potential Transformer (33 kV/110 V, 1Φ, Multi-Core,Outdoor), (1No. per Φ) |
| 158 | 11 kV Switchgear and Allied equipment: 01 No. incomer Bus |
| 159 | 11 kV incomer Bus: Control and Relay (CR) Panel with VCB(12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850] |
| 160 | 11 kV Incomer Bus: Potential Transformer (11 kV/110V, 3Φ,Indoor) |
| 161 | 11 kV Cable (11 kV, 400 mm², XLPE, single Core, Armoured){Transformer to 11 kV Bus} {50m+ Spare- 50m} |
| 162 | 11 kV Cable Termination Kit (400 mm², Outdoor) |
| 163 | 11 kV Cable Termination Kit (400 mm², Indoor) |
| 164 | 11 kV Switchgear and Allied equipment: Single (2 No.+1 Spare) Outgoing Feeder |
| 165 | 11 kV Outgoing Feeder: Control and Relay (CR) Panel withindoor VCB (12 kV, 1250 A, 25KA) including CT |
| 166 | 11 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured){Busbar VCB to Isolator} {50m+ Spare- 50m} |
| 167 | 11 kV Cable Termination Kit (185 mm², Outdoor) |
| 168 | 11 kV Cable Termination Kit (185 mm², Indoor) |
| 169 | 33 KV Super Structure and Bus-bar( Extension of Existing Bus Bar) |
| 170 | R.S. Joists, size 12800x250x125 mm 15 supports i.e.4x12.8x37.3) i/c foundation of RS Joist. |
| 171 | R.S.Joists, size 4200x250x125 mm supports for PowerTransformer's LA, , I/C, PowerTransformer's CTs (10x4.2)m =42m |
| 172 | Foundation of R.S. Joist supports |
| 173 | Foundation of CT, PT & LA |
| 174 | M.S. channel iron 125x65 mm, X-arm @13.1 kg/m at 5% wastage for Bus-bar,Isolators,CT, LA's transformer etc(i)10 Meter Long=2 No (II)6 Meter Long=6 No (III)4 Meter Long=10 No Total =96 meter+5% wastage(4.8)=100.8 Says 101 Mater |
| 175 | Nuts & Bolts with Washers off sizes |
| 176 | BUS-BAR |
| 177 | 33 Kv Pin Insulator |
| 178 | 3 Disc insulators Tension String complete with fitting |
| 179 | ACSR conductor 150 mm² at 10 % wastage for Bus Bar & Jumper avarage of 2 meter |
| 180 | Tee connections |
| 181 | PG clamps |
| 182 | EARTHING (33 kV Sub-Station) |
| 183 | Control and LT power cables |
| 184 | Battery Bank 30V, 200 A |
| 185 | Battry Charger 30 V -200 AH with Allied Spares |
| 186 | 11 kV VCB Trolley CGL make |
| 187 | Civil Work |
| 188 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 189 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size) |
| 190 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 191 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 192 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 193 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size) |
| 194 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) |
| 195 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo- Mechanically Treated bars of grade Fe-500D or more. |
| 196 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 197 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm. |
| 198 | Supplying, filling, spreading & leveling gravels of approved size in required thickness, for all leads & lifts, all complete as per direction of Engineer- incharge. |
| 199 | Providingandlayinginpositioncementconcreteofspecifiedgradeexcludingthecostofcenteringandshuttering-Allworkuptoplinthlevel.1:3:6(1Cement:3coarsesand):6gradedstoneaggregate40mm nominal size) |
| 200 | Earthworkinexcavationbymechanicalmeans(Hydraulicexcavator)/manualmeansinfoundationtrenchesordrains(notexceeding1.5minwidthor10sqmonplan),includingdressingofsidesandramming of bottoms, lift upto 1.5 m, including getting outtheexcavatedsoilanddisposalofsurplusexcavatedsoilasdirected,withinaleadof50m.Allkinds of soil. |
| 201 | Centeringandshutteringincludingstrutting,propping etc. and removal of form |
| 202 | Foundations,footings,basesofcolumns,etc.formassconcrete. |
| 203 | Reinforcedcementconcreteworkinwalls(anythickness),includingattachedpilasters,buttresses,plinthandstringcourses,fillets,columns,pillars,piers,abutments,postsandstrutsetc.aboveplinthleveluptofloorfivelevel,excludingcostofcentering,shuttering,finishingandreinforcement1:1.5:3(1cement:1.5coarsesand):3gradedstoneaggregate 20 mm nominal size) |
| 204 | SteelreinforcementforR.C.C.workincludingstraightening,cutting,bending,placinginpositionandbindingallcompleteuptoplinthlevelThermo-Mechanically Treated bars of grade Fe-500D or more. |
| 205 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 206 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 Cement : 4 coarse sand): 8 graded stone aggregate 40 mm nominal size) |
| 207 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:2:4 (1 Cement : 2 coarse sand): 4 graded stone aggregate 40 mm nominal size) |
| 208 | Foundation and plinth |
| 209 | Brick masonary in cm 1:4 in foundation wall of cable o/d trench |
| 210 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 211 | 15 mm cement plaster on rough side of brick masonary in cm 1:4 |
| 212 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 213 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size) |
| 214 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 215 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 216 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 217 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size) |
| 218 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 219 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation |
| 220 | Providing and laying in position cement concrete of specified grade excluding the cost of centering |
| 221 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of |
| 222 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position |
| 223 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including |
| 224 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. |
| 225 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete |
| 226 | Evcavation in foundation trenches etc in earth work pick work. Pick / Jumper work 50%. |
| 227 | P/L C.C.1:3:6 (1 cement:3 sand : 6 agraded stone agg. 40mm nominal size) in foundation and plinth. |
| 228 | Centring and shuttering including strutting, propping etc. and removal of form for: |
| 229 | Foundation, footings, bases of columns, etc for mass concrete. |
| 230 | Providing and laying reinforced cement concrete 1:1.5:3 (1 cement:1.5 sand and 3: graded stone agg. 20mm nominal size |
| 231 | P/L Tor steel / mild steel reinforcement for RCC work the cutting bending and placing complete. Qty same as in item No. 3 |
| 232 | Extension of control room building along with Trenches for 11 Kv Cable, power & control Cable |
| 233 | Eathwork in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.Ordinary rock |
| 234 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size |
| 235 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge |
| 236 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand): 10 graded stone aggregate 40 mm nominal size) |
| 237 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand |
| 238 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 239 | (i) Foundations, |
| 240 | (ii) Columns , pillars |
| 241 | Lintels, beams, plinth beam |
| 242 | Suspended floors, roofs, landings, balconies and access platform |
| 243 | Edges of slabs and breaks in floors and walls under 20 cm. wide. |
| 244 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size) |
| 245 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size) |
| 246 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size). |
| 247 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 248 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 249 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm) |
| 250 | Providing & Fixing Prelaminated board 12mm flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge Pre-laminated particle board with decorative lamination on both side |
| 251 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete |
| 252 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete |
| 253 | Providing and fixing aluminium tower bolts, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 254 | (i) 150x10 mm |
| 255 | (ii) 100x10 mm |
| 256 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 257 | (i) 125 mm |
| 258 | (ii) 100 mm |
| 259 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber |
| 260 | Providing and fixing bright finished brass hard drawn hooks and eyes 200mm |
| 261 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 262 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete ng with bricks of class designation |
| 263 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete 600x600mm |
| 264 | PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 265 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110mm Bend 87.5° 110 mm bend PVC plain bend 150mm dia. |
| 266 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) |
| 267 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand) |
| 268 | 20 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) |
| 269 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 270 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 271 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 272 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 273 | Add sanitary and electrical fitting |
| 274 | Civil Work for foundation of 2 Nos. structures for 11KV Structure |
| 275 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 276 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size) |
| 277 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 278 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 279 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 280 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size) |
| 281 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 282 | Erection part |
| 283 | 11/0.4 kV 630 kVA sub-station with O/D Distribution transformer |
| 284 | Distribution Transformer (Outdoor Type) , 11/0.4 kV, 630 KVA |
| 285 | Steel Tubular Poles (10 m) |
| 286 | Muffs with concerete filling |
| 287 | ACSR Conductor 6/1/3.35, 50 sq. mm for earthing , jumpering & Bus bar etc. Along with 70 m one span from existing line |
| 288 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 4 Nos] |
| 289 | MS Angle Iron (50X50x6 mm), Length: 2800 mm for four pole structure and bus bar etc. |
| 290 | X-Arm: [Channel Iron (75x40x6mm), Length : 2800 mm X 6 Nos] for supporting DO fuse unit , CT-PT Unit & GO switch |
| 291 | Transformer Belting & Knee Bracing |
| 292 | X-Arm [Channel Iron (100x50x6 mm), Length : 2800 mm x 2 Nos for Transformer Bed |
| 293 | X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer |
| 294 | X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of CT/PT Unit |
| 295 | MS Angle Iron (50X50x6 mm), Length : 2800 mm x 2 Nos |
| 296 | MS Angle Iron 35x35x5 mm), Length : 460 mm x 2 Nos |
| 297 | MS Angle Iron 50x50x6 mm), Length : 950 mm x 2 Nos for Bed Knee Bracing |
| 298 | Transformer LT Distribution Box and GO Switch fixing Assembly |
| 299 | MS Angle Iron (50X50x6 mm), Length : 2800 mm x 2 Nos |
| 300 | MS Angle Iron (50X50x6 mm), Length : 450 mm x 1 Nos |
| 301 | GO Switch Handle supporting : [ Channel Iron (75x40x6 mm), Length:460 mm |
| 302 | GO AB Switch Unit (11kV,1000A) ( Isolator Type) |
| 303 | D.O Fuse Unit |
| 304 | Surge Arrester, 9 kV Station Class (Porcelain Type) |
| 305 | Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 306 | Stay set complete |
| 307 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 308 | Pipe Earthing Set |
| 309 | Pin Insulator 11 kV (polymer type) |
| 310 | LT Distribution Panel Box with MCCB for 630 kVA DTR |
| 311 | Half Clamp (M.S. Flat 50X6 mm) |
| 312 | Full Clamp ( M.S Flat 50x6 mm) |
| 313 | Stay Clamp |
| 314 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 315 | Aluminium Thimble |
| 316 | Copper Thimble |
| 317 | Danger Plate |
| 318 | Barbed Wire |
| 319 | LT Cable (3.5 Core) 500 mm² |
| 320 | LT Cable (PVC) 3.5 core 300 sq. Mm from LT panel Box to EV Charging Panel Box length up to 40 m x 2 |
| 321 | Aluminium Paint. |
| 322 | Red Oxide Paint |
| 323 | Kit Kat 500 Amp for section |
| 324 | LT Switched Capacitors for 630 KVA DTR (216 kVAr) |
| 325 | CT-PT Unit arrangement along with metering for 630 kVA S/stn |
| 326 | Three Phase CT-PT Combined Unit 11 kV/110 V, 100/5A, accuracy class 0.5 s |
| 327 | Energy Meter (3-Phase, 4-Wire) DLMS compliant 630 A CT Type for 630KVA Transformer ( C-Type) |
| 328 | i) Multi Strand Copper Cable for CT-PT and Meter Connection 10C, 2.5 sq mm |
| 329 | ii) 1 inch dia GI pipe for concealin |
| 330 | iii) bend joints/ elbow |
| 331 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 332 | X-arm Channel Iron (75x40x6 mm): Length 2800mmx2 nos.) for supporting main channel for CT-PT Unit |
| 333 | CT-PT Unit Belting and knee Bracing a) M.S Angle Iron (50x50x6 mm), Length 2800mmx4 Nos. |
| 334 | CT-PT Unit Belting and knee Bracing a) M.S Angle Iron (35x35x6 mm), Length 2800mmx2 Nos. |
| 335 | Half Clamp (M.S. Flat 50X6 mm) |
| 336 | Full Clamps (M.S. Flat 50X6 mm) |
| 337 | 11/0.4 kV 250 kVA sub-station with O/D distribution transformer |
| 338 | Distribution Transformer (Outdoor Type) , 11/0.4 kV, 250 KVA |
| 339 | Steel Tubular Poles (10 m) |
| 340 | Muffs with concerete filling |
| 341 | ACSR Conductor 6/1/3.35, 50 sq. mm for earthing , jumpering & Bus bar etc. Along with 70 m one span from existing line |
| 342 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 4 Nos] |
| 343 | MS Angle Iron (50X50x6 mm), Length: 2800 mm for four pole structure and bus bar etc. |
| 344 | X-Arm: [Channel Iron (75x40x6mm), Length : 2800 mm X 6 Nos] for supporting DO fuse unit , CT-PT Unit & GO switch |
| 345 | Transformer Belting & Knee Bracing |
| 346 | X-Arm [Channel Iron (100x50x6 mm), Length : 2800 mm x 2 Nos for Transformer Bed |
| 347 | X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer |
| 348 | X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of CT/PT Unit |
| 349 | MS Angle Iron (50X50x6 mm), Length : 2800 mm x 2 Nos |
| 350 | MS Angle Iron 35x35x5 mm), Length : 460 mm x 2 Nos |
| 351 | MS Angle Iron 50x50x6 mm), Length : 950 mm x 2 Nos for Bed Knee Bracing |
| 352 | Transformer LT Distribution Box and GO Switch fixing Assembly |
| 353 | MS Angle Iron (50X50x6 mm), Length : 2800 mm x 2 Nos |
| 354 | MS Angle Iron (50X50x6 mm), Length : 450 mm x 1 Nos |
| 355 | GO Switch Handle supporting : [ Channel Iron (75x40x6 mm), Length:460 mm |
| 356 | GO AB Switch Unit (11kV,600A) ( Isolator Type) |
| 357 | D.O Fuse Unit |
| 358 | Surge Arrester, 9 kV Station Class (Porcelain Type) |
| 359 | Discs insulator sets (comprising 1 No. Disc: ^^(Polymeric, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 360 | Stay set complete |
| 361 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 362 | Pipe Earthing Set |
| 363 | Pin Insulator 11 kV (Polymeric type) |
| 364 | LT Distribution Panel Box with MCCB for 250 kVA DTR |
| 365 | Half Clamp (M.S. Flat 50X6 mm) |
| 366 | Full Clamp ( M.S Flat 50x6 mm) |
| 367 | Stay Clamp |
| 368 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 369 | Aluminium Thimble |
| 370 | Copper Thimble |
| 371 | Danger Plate |
| 372 | Barbed Wire |
| 373 | LT Cable (3.5 Core) 300 mm² |
| 374 | LT Cable (PVC) 3.5 core 240 sq. Mm from LT panel Box to EV Charging Panel Box length up to 30 m x 2 |
| 375 | Aluminium Paint. |
| 376 | Red Oxide Paint |
| 377 | Kit Kat 500 Amp for section |
| 378 | LT Switched Capacitors for 250KVA DTR (81 kVAr) |
| 379 | CT-PT Unit arrangement along with metering for 250 kVA S/stn |
| 380 | Three Phase CT-PT Combined Unit 11 kV/110 V, 50/5A, accuracy class 0.5 s |
| 381 | Energy Meter (3-Phase, 4-Wire) DLMS compliant 400 A CT Type for 250 KVA Transformer ( C-Type) |
| 382 | i) Multi Strand Copper Cable for CT-PT and Meter Connection 10C, 2.5 sq mm |
| 383 | ii) 1 inch dia GI pipe for concealin |
| 384 | iii) bend joints/ elbow |
| 385 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 386 | X-arm Channel Iron (75x40x6 mm): Length 2800mmx2 nos.) for supporting main channel for CT-PT Unit |
| 387 | CT-PT Unit Belting and knee Bracing a) M.S Angle Iron (50x50x6 mm), Length 2800mmx4 Nos. |
| 388 | CT-PT Unit Belting and knee Bracing a) M.S Angle Iron (35x35x6 mm), Length 2800mmx2 Nos. |
| 389 | Half Clamp (M.S. Flat 50X6 mm) |
| 390 | Full Clamps (M.S. Flat 50X6 mm) |
| 391 | Bifurcation of new 11 kV Feeder from 33/11 kV Sub-station Chamba to Baloo- 11 kV HT Line on Steel Tubular poles-2.915 km |
| 392 | Providing Steel Tubular Poles 9 Mtr. Long |
| 393 | Providing Steel Tubular Poles 10 Mtr. long |
| 394 | Muffs with concrete filling |
| 395 | Prov. ACSR 6/1/3.35 mm [{ includes 3 conductor length for 3 ph and additional 3 % ( sag., jumpering and wastage) |
| 396 | Prov. 11 kV Disc Insulator complete set including dead end clamps etc |
| 397 | Prov. 11 kV Pin Insulator (3 No. per Single pole structure and 3 No. per Double Pole structure) |
| 398 | X-Arm (C.I. 2340x100x50x6 mm) i/c tolerance of 100 mm either side |
| 399 | X-Arm (C.I. 1270x100x50x6 mm) i/c tolerance of 100 mm either side |
| 400 | X-Arm (C.I. 1800x100x50x6 mm) i/c tolerance of 100 mm either side |
| 401 | X-Arm (C.I. 2340x75x40x6 mm) i/c tolerance of 100 mm either side |
| 402 | M.S A.I 50x50x6 Length 1800 mmx2 No. belt set |
| 403 | A.I. Knee Bracing set 2(750x50x50x6mm) |
| 404 | A.I Cross Bracing Set complete |
| 405 | Pole Top Bracket [MSCI 100x50x6 mm-100 mm}] |
| 406 | Stay set complete (1 No. for Single Pole, 5 Nos. for Double Pole structure) |
| 407 | Egg Ins. |
| 408 | Stay Wire (10 kg per set) |
| 409 | GO AB Switch Unit (11kV 400 A, 25 KA) |
| 410 | Earthing set H.T complete in all respect |
| 411 | Single Continuous earth wire ( GI, 8SWG) |
| 412 | MS Angle Iron 50x50x6 Length 2400 mm for guarding Angle |
| 413 | Eye Hook |
| 414 | Earth wire clamp |
| 415 | Barbed Wire |
| 416 | Half clamp |
| 417 | Full clamp |
| 418 | Stay clamp |
| 419 | Prov. Danger Plate |
| 420 | Prov. Nut & Bolts off sizes |
| 421 | Prov. Aluminium paint |
| 422 | Prov. Red Oxide Paint |
| 423 | Re-sagging of existing ACSR conductor6/1/3.35 |
| 424 | Augmentation of 33/11 kV , 2.5 MVA Sub-Station( Damaged ) to 3.15 MVA Sub station in 33/11KV 2X10 MVA S/Stn Chamba |
| 425 | Power Transformer (3.15 MVA, 33/11 kV, ONAN, OLTC,Outdoor) |
| 426 | 33 kV Switchgear & Allied Equipment: with 01 No., 33kV Incomer |
| 427 | 33 kV Control and Relay (CR) Panel (with Numeric Differential Relay, IEC 61850) |
| 428 | 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type) |
| 429 | 33 kV Isolator (1250 A, 25kA, with Earth Switch) with structure |
| 430 | 33 kV Isolator (1250 A, 25kA, without Earth Switch) with structure |
| 431 | 33 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO,Porcelain) |
| 432 | 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core,Outdoor) (1 No. per Φ) 600/300 |
| 433 | 33 kV Potential Transformer (33 kV/110 V, 1Φ, Multi-Core,Outdoor), (1No. per Φ) |
| 434 | 11 kV Switchgear and Allied equipment: 01 No. incomer Bus |
| 435 | 11 kV incomer Bus: Control and Relay (CR) Panel with VCB(12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850] |
| 436 | 11 kV Incomer Bus: Potential Transformer (11 kV/110V, 3Φ,Indoor) |
| 437 | 11 kV Cable (11 kV, 400 mm², XLPE, single Core, Armoured){Transformer to 11 kV Bus} {50m+ Spare- 50m} |
| 438 | 11 kV Cable Termination Kit (400 mm², Outdoor) |
| 439 | 11 kV Cable Termination Kit (400 mm², Indoor) |
| 440 | 11 kV Switchgear and Allied equipment: Single (2 No.+1 Spare) Outgoing Feeder |
| 441 | 11 kV Outgoing Feeder: Control and Relay (CR) Panel withindoor VCB (12 kV, 1250 A, 25KA) including CT |
| 442 | 11 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured){Busbar VCB to Isolator} {50m+ Spare- 50m} |
| 443 | 11 kV Cable Termination Kit (185 mm², Outdoor) |
| 444 | 11 kV Cable Termination Kit (185 mm², Indoor) |
| 445 | 33 KV Super Structure and Bus-bar( Extension of Existing Bus Bar) |
| 446 | R.S. Joists, size 12800x250x125 mm 15 supports i.e.4x12.8x37.3) i/c foundation of RS Joist. |
| 447 | R.S.Joists, size 4200x250x125 mm supports for PowerTransformer's LA, , I/C, PowerTransformer's CTs (10x4.2)m =42m |
| 448 | Foundation of R.S. Joist supports |
| 449 | Foundation of CT, PT & LA |
| 450 | M.S. channel iron 125x65 mm, X-arm @13.1 kg/m at 5% wastage for Bus-bar,Isolators,CT, LA's transformer etc(i)10 Meter Long=2 No (II)6 Meter Long=6 No (III)4 Meter Long=10 No Total =96 meter+5% wastage(4.8)=100.8 Says 101 Mater |
| 451 | Nuts & Bolts with Washers off sizes |
| 452 | BUS-BAR |
| 453 | 33 Kv Pin Insulator |
| 454 | 3 Disc insulators Tension String complete with fitting |
| 455 | ACSR conductor 150 mm² at 10 % wastage for Bus Bar & Jumper avarage of 2 meter |
| 456 | Tee connections |
| 457 | PG clamps |
| 458 | EARTHING (33 kV Sub-Station) |
| 459 | Control and LT power cables |
| 460 | Battery Bank 30V, 200 A |
| 461 | Battry Charger 30 V -200 AH with Allied Spares |
| 462 | 11 kV VCB Trolley CGL make Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail