| 1 | Steam Indicator Tap Class I | Lead Free Autoclave Tape roll |
| 2 | Steam Indicator Tap Class 5 Moving front technology | Self Adhesive ,Moving front Chemical integrators, indicating Accept orReject to verify allperimeters of steam sterilization together i e Time, Temperature and Quality of steam Can be used for pack control monitoring of all 118138 C 245280 F steam sterilization cyclesShould be compliant to BS EN ISO 111402005 Should have 510 k registration Should have a BSI Kitemark Certificate Pack of 500 PC 2 boxcase |
| 3 | Steam Biological Indicators SRBI | Rapid readout biological indicators for steam sterilization containing astandardized viable population of Bacillus stearothermophilus spores The indicator detects the presence of viable spores by the production of fluorescence in 3 hours in conjunction with Rapid Readout Incubator Designed and certified as per ISO 11138 and EN 866Should be compatible with the following cyclesa 121 123 C gravity steam sterilization Cycleb 132 135 C vacuum-assisted steam sterilization cycles Should be compliant to ISO 111381 2006 en Part 1 and ISO 111381 2006en Part 3Every box should contain Quality Assurance certificate with mention of Spore population D value Z valueShould have a BSI Kitemark CertificateShould have FDA clearance |
| 4 | ETO Cartridge 10 gram Big ETO | for ETO sterilization |
| 5 | ETO Cartridge 40 gram Small ETO | for ETO sterilization |
| 6 | ETO Bio logical Indicators SRBI | Rapid readout biological indicators containing a standardizeviable populationof Bacillus Atropheus spores for ETO Sterilization CyclesThe indicator detects the presence of viable spores by the production of fluorescence within 4 hours in conjunction with Rapid Readout IncubatorDesigned and certified as per ISO 11138 and EN 866 Should be compliant to ISO 11138 1 2006 en Part 1 and ISO 1113812006en Part 2Every box should contain Quality Assurance certificate with mention of Spore population, D value Z valueShould have a BSI Kitemark CertificateShould have FDA clearance |
| 7 | dimethyl Benzyl ammonium chloride solution dimethyl ethylbenzyl ammonium chloride solution | for ETO sterilization |
| 8 | ETO Packing Roll Size 150 x 200 | for ETO sterilization |
| 9 | ETO Packing Roll Size 250 x 200 | for ETO sterilization |
| 10 | ETO Packing Roll Size 400 x 200 | for ETO sterilization |
| 11 | Bowie Dick Pack Lead Free | ISO 1114012014 and 1114052007Designed for testing air removal efficiency of 132134C 270 273F dynamic-air removal steam sterilizersTest pack will reproducibly detect residual air in the sterilizer chamber due to air leaks, air removal failures and inadequate vacuum by testing the air removal efficiency of 132 134C 270 273 F dynamic air-removal steam sterilizersIndicator sheet will turn a uniform dark color except when air removal failures, such as air leaks, occurLead freeEquivalent in performance to the Bowie-Dick Towel Pack described in ANSI AAMI ST79Does not change visually 24 months when properly stored Includes a scanable 2D bar code with lot number and expiration date for record keepingIncludes a process indicator on the test pack label Preassembled, single use designed for consistent performance resultsInk pattern design for easy interpretation Two year shelf lifeSheet can be filed for record keeping |
| 12 | dimethyl Benzyl ammonium chloride solution dimethyl ethylbenzyl ammonium chloride solution | surface disinfectant |
| 13 | Hydrogen peroxide and silver solution HP10 | surface disinfectant and fogger solution |
| 14 | Ultra Rapid Multienzyme cleaner 1 Liter | Multiple enzymatic concentrate solution with lipases cellulases, proteases and amylases Must act against all possible body secretions, compatible to all instrumentsFast acting within 2 10 minutes, allow safe disposable via the drain after use Leaves no residue after wash, Stable formulation with near neutral pH. Should have scale inhibition properties Should help retain shine of the instrument Should be usable for manual, ultra sonic and automatic cleaning systemsProperties should have been tested by methods prescribed by NACE TM0374 2007 NACE TM0169 ASTM G31 2012 1 Liter |
| 15 | Fabric incise drape iodinised | Incisde drape made up of Polyester film with an acrylic adhesive that contains a complex of iodoformN vinyl 2 pyrrolidine with a iodine concentration of 0.092 mg Iodinecm2. Film should be breathable and conformable to skin, compatible with Povidone and CHG skin preps Iodine from the drape should be present in the deepest skin layers 1000 microns depthwhere hair folices exist apart from killing microbes on skin layer. Size 26x20 cm with frame delivery mechanism which allow application by single person. |
| 16 | Negative pressure wound therapy system small | Negative Pressure Wound Therapy System Dressing kits containing Small Polyurethane Ether Black Foam Dressing10 x 7.5 x 3 cm with one drape, ruler, trac pad with double tubing along with 600 Ml Canister. It should be CDSCO, ISO CE Certified should be ETO Sterilize |
| 17 | Negative pressure wound therapy system medium | Negative Pressure Wound Therapy System Dressing kits containing Medium Polyurethane Ether Black Foam Dressing 18 x 12 5 x 3 cm with one drape, ruler, trac pad with double tubing along with 600 Ml Canister. It should be CDSCO, ISO CE Certified should be ETO Sterilize |
| 18 | negative pressure wound therapy system large | Negative Pressure Wound Therapy System Dressing kits containing Large Polyurethane Ether Black Foam Dressing 25 cm x 18 cm x 3 cm with one drape, ruler, trac pad with double tubing along with 600 Ml Canister. It should be CDSCO, ISO CE Certified should be ETO Sterilize |