| 1 | Civil Work |
| 2 | 2.31Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees andsaplings of girth up to 30 cm measured at a height of 1 m above ground level andremoval of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 3 | OD185105/2025-2026Cutting, felling and removing trees of all girths within a width of 6 meters along theproposed fencing alignment , stacking of serviceable wood within 50 m lead, anddisposal of unserviceable material as directed by the Engineer-in-Charge, complete inall respects. |
| 4 | 2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 5 | 4.1.3Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarsesand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 6 | 50.10.2Steel work for purlin/single section with G I pipes including cutting, hoisting, fixingin position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete |
| 7 | Electrical Work |
| 8 | OD185087/2025-2026ENERGIZER FOR HANGING FENCE With the following specifications 12VENERGIZER,9.9 KV output AC, input 12 V DC, minimum 4 Jule must be from a reputed company, must confirm to CPRI certificate and all National and International standards of safety. Switch to high, medium and low power settings. Should possess the following output characters - Peak o/p voltage not more than 9.90 KV O/p energy 4 to 4.5 J minimum - Pulse duration 1.01-3.0 m. sec - Pulse interval 1.1-1.4 sec -including all testing charges etc.. completed with minimum 3 years replacementwarranty against manufacturing defects |
| 9 | OD185102/2025-2026180W solar module (mono- or polycrystalline solar cells) is a compact and efficientphotovoltaic panel designed for off-grid and small-scale solar power applications. Itscompact design makes it ideal for limited-space installations such as on rooftops,solar streetlights, RVs, or rural solar systems, while still delivering reliable energyoutput to charge 12V batteries |
| 10 | OD185095/2025-2026MODULE STAND WITH BOX With MS thickness tilted to 13-15 degree waterproof box for safe up keeping of Solar system including Energizer, battery etc... |
| 11 | OD185100/2025-202612.8V 150Ah Solar Tubular Battery ,Deep cycle, long-life tubular battery designedfor solar applications with high efficiency, low maintenance, fast charge acceptance,and reliable backup for inverters and renewable energy systems |
| 12 | OD185099/2025-2026A C CHARGER Charging current minimum 8A, High charging volt cut off 14.20 Vfrom reputed companies with minimum 1 year warranted |
| 13 | OD185092/2025-2026LIGHTNING DIVERTER Must be capable of diverting stray lightening. The diverterassembly must be adjustable for spark gaps.; Adequate earthing to be provided |
| 14 | OD185103/2025-2026EARTHING SYSTEM Must contain earth mixture capable of retaining moisture and8 mm dia stainless steel rod grade 304 or above non rusting quality of 4 feet long fixing in min 30cm dia and 50cm depth pit |
| 15 | OD185101/2025-2026SUPER STRAIN INSULATOR Must be of polypropylene /poly carbon material andshould withstand of 16 KV. |
| 16 | OD185090/2025-2026WARNING SIGNS Poly ethylene plastic with statutory colors and signs of nominalsize |
| 17 | OD185104/2025-2026LEAD OUT CABLE Must be double insulated withstanding 15 KV voltage and Innercore wire must be GI |
| 18 | OD185096/2025-2026BOTTOM FIXTURE: Includes A. GI/GP SQUARE TUBE of 32 inches length, 2.5inches inner diameter,14 gauge, HDPP material with ISI standards. B. BUSH- UVstabilized, heat resistant, non electrical conductible poly propylene material for fixinginside the square tube. |
| 19 | OD185094/2025-2026STAINLESS STEEL WIRE ROPE 1.5 1.5mm 304 grade, non rusting quality for bothmain horizontal lines and vertical hanging. Including all standard specification |
| 20 | OD185086/2025-2026STAINELESS STEEL WIRE 1.5mm, 304 grade, non rusting quality |
| 21 | OD185089/2025-2026BULLETS (Ferrul) Connectors of Aluminum 2.5 mm material. good quality |
| 22 | OD185097/2025-2026JOINT CLAMPS. Positive locking mechanism Zinc coating of more than 25 micronswith nuts and bolts |
| 23 | OD185091/2025-2026TOOL KIT. Including bolt cutter 14 inch length, cutting pliers, twisting toolkit,multimeter, Volt meter,Neon Tester, double ended spanner. From reputed companies like Taparia or equivalent |
| 24 | OD185093/2025-2026DIGITAL VOLT METER. As per the required specification. Quality should ensurewith replacement warranty for minimum 3 years. minimum 10 KV capacity formeasuring fencing line volt |
| 25 | OD185088/2025-2026ERECTION OF HANGING FENCE (Installation, Testing and commissioning withall materials) AS PER STD SPECIFICATION AND THE DIRECTION OFOFFICER IN CHARGE |
| 26 | OD185098/2025-2026PROVIDING G.S.M ALERT SYSTEM- With fence voltage alarm and SMS alert tominimum 3 mobile numbers. Two additional relay contacts provided. Alarm can beswitched on or off by a missed call Please Enable Macros to View BoQ information |