| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed Heavy class PVC Conduit having wall thickness minimum 2.0 mm , with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Make:- Anchor (Roma classic )/ L&T(Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge. |
| 2 | Group - C |
| 3 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed Heavy class PVC Conduit having wall thickness minimum 2.0 mm , 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Make:- Anchor (Roma classic )/ L&T(Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge. |
| 4 | Wiring for Group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor singlecore cable etc as required.Make:- Anchor (Roma classic )/ L&T(Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge. |
| 5 | Group c |
| 6 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.ke :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge |
| 7 | 5/6 amp Modular switch |
| 8 | 5 pin 5/6 amp socket outlet |
| 9 | Telephone socket |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. Make :-Anchor (Roma classic )/L&T(Entice) /Legrand(Myrius) as approved by Engineer-In-Charge |
| 11 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 amps modular socket outlets and 2 nos 5/6 amps modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).ke :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge |
| 12 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.Make :-Anchor (Roma classic )/L&T (Entice)/Legrand(Myrius) as approved by Engineer-In-Charge |
| 13 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 , 3pin 5/6 amp modular socket outlet and 15/16 amp&5 /6 amp modular switch, connection etc. as required. Make :-Anchor (Roma classic )/L&T(Entice)/ Legrand (Myrius) as approved by Engineer-In-Charge |
| 14 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. |
| 15 | Supplying and fixing Computer board comprising 3 nos 5 amp modular switches & Sockets , G.I box 2 module for jack box and G.I Box 12 module for 5 amp switchs and 5 amp sockets comprising sheet cover for each 2 module metal box , one no computer jack (RJ-45)with shutter including connections etc as required.ke :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge |
| 16 | Supplying and fixing Ding Dong bell suitable for single phase, 230 volts, complete as required. Make :-Anchor (Roma classic )/ L&T(Entice) /Legrand(Myrius) as approved by Engineer-In-Charge |
| 17 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required . Make:-Finolex/Polycab/Plaza as approved by Engineer-In-Charge |
| 18 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 19 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 20 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 21 | 2 X 10sq. mm + 1 X 6 sq. mm earth wire |
| 22 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.Make:-Finolex/ Polycab/ Plaza as approved by Engineer-In-Charge |
| 23 | 3 x 1.5 sq. mm |
| 24 | 3 x 4 sq. mm |
| 25 | Supplying and drawing of telephone cable of following size high conductivity copper conductor ,with high density polythylene insulation , paired ,polyster,and sheathedwith grey coloured, pvc compound telephone cables generally conforming to ITD specifications in the existing surface/recessed steel/ PVC conduit including conections,as required. Make:-Finolex/Polycab/Plaza as approved by Engineer-In-Charge |
| 26 | 2 pair telephone Cable |
| 27 | Supplying and fixing of following sizes of Heavy class FRLS PVC Conduit having wall thickness minimum 2.0 mm along with accessories in surface/recess including cutting the wall and making good as required. Diplast/BEC/Polyfit as approved by Engineer-In-Charge |
| 28 | 25 mm |
| 29 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable,IS 7098 1.1 KV grade of following sizes on wall surface with appropriate size lugs, gland as required. |
| 30 | Armoured cable 25 sq. mm (3.5 core) |
| 31 | Armoured cable 50 sq. mm (3.5 core) |
| 32 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 33 | Armoured cable 50 sq. mm (3.5 core) |
| 34 | Providing, Installation, testing and commissioning of BLDC ceiling fan including five year warranty with socket type 2 module regulator,including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mmt win twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required.Five star rating (Five year warranty)Make:- Usha (Technoaire BLDC without remote)/Orient/,Crompton as approved by Engineer-In-Charge |
| 35 | Ceiling Fan 1200 mm sweep |
| 36 | Supplying and fixing extra conduit down rod of 60 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored). |
| 37 | Providing, Installation, testing and commissioning of wall fan of aluminium blades ,rust free, following size by means of suitable rag-bolt/ nuts, connections, testing and commissioning etc. as required complete in all respects to the best satisfaction of Engineer-in-charge .(Five year warranty) |
| 38 | Wall Fan 400 mm sweep. |
| 39 | Providing and installation exhaust fan of 300mm Light duty size in the existing opening,including making the hole to suit the size of the above fan, making good thedamages, connections, testing and commissioning etc. as required: Make:- Usha (Technoaire BLDC without remote)/Orient/,Crompton as approved by Engineer-In-Charge |
| 40 | Providing and installation exhaust fan of 300 mm sizes PVC body in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required.(Five year warranty)Make:- Usha (Technoaire BLDC without remote)/ Orient/ Crompton as approved by Engineer-In-Charge |
| 41 | Exhaust Fan, Light duty, (Domestic) |
| 42 | Supplying and fixing exhaust fan louver shutter for 300 mm.exhaust fan on the existing wall,painting etc, as required, |
| 43 | Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required.(Five year warranty) |
| 44 | 25 Liter capacity water heater (Cat-A) |
| 45 | Supply and fixing of IP40 Led fixture 40 W+/- 2W with Surface Mounted 4 Feet with with anodised aluminium reflector Polycarbonate diffuser with aluminium housing minimum lumen output 4400 lumens and system lumen efficacy of 110 lm/W with P.F.>0.95 with THD<10% ,CCT 5700K, CRI 80,Surge Protection 3 KV .The LEDs with minimum life of 50000 burning hours. The Input voltage range shall be 150V to 270V.including ,hanging arrangement ,complete in all respect. Make Philips/Wipro/LT as approved by Engineer-in-Charge.(five year warranty) |
| 46 | Supply and fixing Supply of IP20 Led fixture 2FT 10 W+/- 1W with Surface Mounted 2 Feet with aluminium housing and Polycarbonate diffuser,minimum system efficacy of 100lm/W with P.F.>0.90 with THD<20% ,CCT6500 K,CRI 80,Surge Protection 2 Kv, IP20.The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 150V to 270V.including ,hanging arrangement ,complete in all respect. Make Philips/Wipro/LT as approved by Engineer-in-Charge.(five year warranty) |
| 47 | Supply and fixing of Led fixture 4Ftx1Ft 36 W+/- 1W Recess/Surface mounted Mounted with HET plastic diffuser with CRCA powder coated housing having efficacy of 100 lm/W with P.F.>0.95,THD<10%. The LED with useful life of 5000 hrs at L70. The LED used in the luminaire shall have CCT of 5000-5700K with CRI of minimum 80. The input voltage range shall be 150V-270V. Fixture have surge protection 2KV. Driver output voltage shall be less than SELV limits for safe operation and maintenance complete with all accessories, connections, testing and commissioning etc.as required.( Five year warranty) |
| 48 | Supply and fixing of backlit non slim surface/Recess led downlighter in 12 W +/- 1 W in Round Shape with with minimum system lumen efficacy of 120 lm/W and minimum system lumens 2880 lumen with Pressure Die cast Aluminium heat sink with and HET diffuser and polycarbonate mounting box P.F.>0.95 ,THD<10% ,CCT 5700K/4000K, CRI 80, UGR<23,IP20 protection.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2kV .Driver including ,hanging arrangement ,complete in all respect. Make Philips/Wipro/LT as approved by Engineer-in-Charge.(five year warranty) |
| 49 | Supply and fixing of backlit non slim surface/Recess led downlighter in 18 W +/- 1 W in Round Shape with with minimum system lumen efficacy of 120 lm/W and minimum system lumens 2880 lumen with Pressure Die cast Aluminium heat sink with and HET diffuser and polycarbonate mounting box P.F.>0.95 ,THD<10% ,CCT 5700K/4000K, CRI 80, UGR<23,IP20 protection.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2.5kV .Driver including ,hanging arrangement ,complete in all respect. Make Philips/Wipro/LT as approved by Engineer-in-Charge.(five year warranty) |
| 50 | Supply and fixing of led downlighter in 24 W +/- 1 W LED Surface Mounted Downlighter Round Shape with minimum system lumen efficacy of 100 lm/W and system lumen 2400lm with Pressure Die cast Aluminium Housing and HET diffuser and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80, IP20 optical compartement.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2kV .Driver, complete with all accessories, connections, testing and commissioning etc . Make Philips/Wipro/LT as approved by Engineer-in-Charge.(five year warranty) |
| 51 | Supply and fixing of Led fixture 600mmX600mm 36 W+/- 1W Recess/Surface Mounted with HET diffuser with minimum system lumen efficacy of 120lm/W and system lumen of 4320lm with CRCA Housing and with P.F.>0.95,THD<10%,CCT 5700 K/4000K, internal surge protection 2.5KV with input voltage range of 150V-270V,CRI 80,UGR<22.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70, connections, testing and commissioning etc as complete in all respect . .(five year warranty) |
| 52 | Supply and fixing of Wellglass LED downlighter in 35 W +/- 1 W with with minimum system lumen efficacy of 120 lm/W and minimum system lumens 2880 lumen with Pressure Die cast Aluminium heat sink with and HET diffuser and polycarbonate mounting box P.F.>0.95 ,THD<10% ,CCT 5700K/4000K, CRI 80, UGR<23,IP20 protection.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2.5kV .Driver including ,hanging arrangement ,complete in all respect. Make Philips/Wipro/LT as approved by Engineer-in-Charge.(five year warranty) |
| 53 | Supplying and fixing street light LED 60 watt IP66 with G.I bracket die cast Aluminium housing with frame and toughened glass, pipe mounting 5700k, (Five YEAR WARRANTY ) and it should be compatible with specification e.i. Power Factor > .9, Harmonic Distortion<10% and efficacy >120 Lumens per wat and lumen out put 6500 lumens suitable for input voltage: AC 220-240 V, 50/60Hz with 10kv surge protection including G.I bracket , complete with all accessories, connections, testing and commissioning etc. Make - Philips /wipro/LT as approved by Engineer-in-Charge |
| 54 | Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation made from (50 mm x 50 mm x 6 mm thick) M.S. angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-The panel should be approved /Tested from the CPRI lab.& should confirmed to ISI: 64139 I) i) 300 mm Deep |
| 55 | Cubical panel Overall Size(H) 1000MM X (W) 1000 MM X(D) 300 MM |
| 56 | Supplying and fixing copper strip bus-bars suitable for 100 Amp. 415 volts capacity 4 No. each of cross-sectional area (16mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-: |
| 57 | Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (16mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-: |
| 58 | Providing and fixing 160 AMP , four pole, 415 volts, On-Load change open execution in existing panel , including making connections, etc. as required. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty). |
| 59 | Supplying and fixing of MCCB Four pole following rating and breaking capacity with thermal magnet in release complete with connection ,testing and commissioning etc as required.Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty). ( |
| 60 | 32 amp -18KA. |
| 61 | 63 amp -18KA. |
| 62 | 160 amp -25kA. |
| 63 | Supplying and fixing , 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.) Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty). |
| 64 | Single pole 5-32 amp |
| 65 | Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of double poles in the existing MCB DB complete with connections etc. as required: Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty). |
| 66 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts,10 KA residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty). |
| 67 | 40 AMP |
| 68 | 63 AMP |
| 69 | Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar,din bar, detachable gland plate, interconnections, with appropriate rating copper lugs, gland , powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty). |
| 70 | MCBDB 8 WAY Double Door. |
| 71 | MCBDB 12WAY Double Door. |
| 72 | Supplying and fixing of Voltmeter flush mounting 96x96 mm inbuilt selector switch CT/PT site programmabe accuracy Class 1.0,0.5 complete with connection ;testing and commissioning etc as required Make:-L&T /legrand/Hagger /Schneider as approved by Engineer-in -charge.(five year warranty). |
| 73 | Supplying and fixing of Ammeter flush mounting 96x96 mm inbuilt selector switch CT/PT site programmabe accuracy Class 1.0,0.5 complete with connection,testing and commissioning etc as required Make:-L&T /legrand/Hagger /Schneider as approved by Engineer-in -charge.(five year warranty). |
| 74 | S/F indicator set R Y & B with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required. |
| 75 | S/F Shock treatment chart on the existing wall etc as required including carriage of material within all leads and lift. |
| 76 | supplying and fixing CT coil 600/5 amp with burden of VA 15 accuracy class -1 .Make:- Automatic Electric Ltd/L&T/Legrand as approved by E-in- charge. |
| 77 | S/F rubber mat 1x 2 meter long 12mm thick infront of main panel as required including carriage of material with in all leads and lift. |
| 78 | Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. including charcoal or coke and salt ) complete as required. |
| 79 | Supplying and laying lighting arrestor 1mtr copper electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer ) |
| 80 | Supplying and laying 20 mm X 3 mm copper strip as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 81 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 82 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/ PVC conduit including conections,as required. |
| 83 | Supplying and fixing Loaded Wall- Wall Mount 2u Dimensions 44 X57 X20 CM Front Glass Door(tinted,toughened) with LOCK &KEY, 2PAIRS OF I9\\" Mounting Rail with U-Marking welded Side walls !U Cable Manager (1) Hardware Packet (1Pkt)3 socket 5amp .power distribution Unit(1NO) . |
| 84 | Supplying and fixing 8-port 10/100/1000Mbps Unmanaged standalone gigabit switch in desk top (green ethernet) for getting blazing speed of giga bite that delivers power performance and reliability i.e increasing the speed of net work server in large in switching protocol storing and forwarding as required .. |
| 85 | Supply and fixing of IP20 Smart PIR Occupancy Sensor having 360 degree Detection Pattern with maximum dectection Diameter of 6 meters at maximum height of 4.5 meters haviing Power consumption of 1.8 Watt with Off Delay Timing of 1-90 minutes complete with all accessories, connections, testing and commissioning etc.as required. complete with all accessories, connections, testing and commissioning etc.as required. Make Philips/Wipro/Osram/Jaquar/panasonic as approved by Engineer-in-Charge.(five year warranty) |
| 86 | Providing and commissioning of self supporting stool type ladder heavy duty made out of aluminium section of 115 mm ribbed nonislip steps with large plateform of size 482x380 mm ,150mm brake type tyre castors for easy movement ,handrails 1 meter railing height from plateform for climbing comfort,guard rail 1 meter railing height from plate form complete in all respect as required. |
| 87 | 8 ft Height. |
| 88 | Supplying and fixing Surge protection device protection against indirect/direct lighting surges maxiumum dicharge current- I max upto 50 KA/ 3 pole+neutral Type 1+2 . |
| 89 | Supplying and laying of HDPE Pipe 90 mm dia for supplying and drawing of armoured cable complete in all respects as required. |
| 90 | Online UPS - Input supply: Single Phase, Out put Supply: Single Phase |
| 91 | Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor)ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, SinglePhase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA,SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology.The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and deliveringoutput AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage,battery over charging, output over current, short. |
| 92 | circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage powerparameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved asper EN 6204, EN6204 Part I and Part 2, it shall be aVoltage and Frequency Independent (VFI) type UPS(as per standard IEC 62040-1, 2 & 3) . The UPSshould be with IGBT Based Inverter Technology,Communication RS232/ RS485/ SNMP port openprotocol for BMS integration as per approved byEngineering in charge. Required battery racks, DC breaker of suitable rating and interconnectingcopper conductor cable of suitable size,including rack andconnectors and all required accessories are inclusive in the cost. Five year warranty . |
| 93 | 10 kva UPS |
| 94 | Providing and fixing of 4 Kg. ABC MAP-50% Powder type fire extinguishers are manufactured and marked to Indian standard IS: 15683. Hose shall made of EPDM Rubber, CE Marked Valve, Suitable first aid appliance for fighting fires in Class A, B & C fire that is wood, textile, flammable liquids & gases. |
| 95 | Providing & fixing of CO2 gas 4.5 kg ISI marked (IS:15683) portable fire extinguisher, carbondioxide type flat base including valve, discharge hose of not less than 10 mm dia. 1 M long & complete in all respects including initial fill confirming to IS:15222 filled to a filling ratio of not more than 0.667 and wall suspension bracket. |
| 96 | Providing and fixing Water CO2 9 .Litrs type fire extingushers consisting of seamless cylindrical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube, 30cms long high pressure discharge hoase, discharge nozzle, suspension bracket, confirming to IS: 15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Please Enable Macros to View BoQ information |