| 1 | Supplying, Installation, Testing and Commissioning of 1 No minimum 13 passenger MRL traction elevator of with the following specifications with latest is 17900 code and features. Make :- KONE /OTIS / MITSUBISHI/TKE |
| 2 | Type and Capacity : 884Kg or better, 13 Passengers Minimum |
| 3 | Speed : 1.5/1.75 meter per second |
| 4 | Travel :- 34.5 mtr(approx.) (B1+B2+G+3) |
| 5 | Controller : LVA/ACD |
| 6 | Serving:- 7 stop with all opening on all same side. |
| 7 | Hoist way Dimensions:-2250 MM W X 2650 MM D |
| 8 | Head Room Required :- 47 METER |
| 9 | PIT Depth:-1600 MM |
| 10 | CAR SIZE:-1600 MM Wx 1350 mm D x 2300 mm H) |
| 11 | CAR ENCLOSURE:- Constructed out of S.S. panels with Honey comb finish |
| 12 | CAR ENTRANCE:- Two speed slide side opening automatic S.S. panels in Honey comb finish with a clear opening |
| 13 | CAR & HOISTWAY DOOR TYPE:-Central opening power operated landing door in SS 1.5 MM Honey comb. |
| 14 | DOOR OPENING:-900 MM W X2100 H |
| 15 | DOOR OPERATION:- Automatic D.C. door operation with adjustable door opening & closing timing |
| 16 | POWER SUPPLY :- 400/415 Volts, 3 Phase, A.C. supply, 50 Hz |
| 17 | FAN :- 1 No with 300 mm sweep |
| 18 | FLOORING :- GRANITE |
| 19 | LIGHTING :- orange LED Illumination. |
| 20 | INDICATORS:- LED D & P Indicators in car . |
| 21 | Details :- |
| 22 | Motor compatible for 180 starts per hour. |
| 23 | Car operating panel with luminious floor button in car |
| 24 | Automatic Break Testing |
| 25 | Battery operated alarm bell and emergency light |
| 26 | Fireman's switch and fire rated door for 120 minutes. |
| 27 | Over load warning device Voice announcement . |
| 28 | Control panel on one side in the car and hall button panel at each landing with Stainless Steel (Hair line finish) |
| 29 | Automatic Rescue Device complete with dry maintenance free batteries as required |
| 30 | Hand rail on all thethree sides at 900mm above floor level to be fixed in the lift car. |
| 31 | Voice announcement system (English) in the car to announce the position of the elevator in the hoist way as the car passesor stops at each floors .These System should work during ARD operation also. |
| 32 | Braille buttons for visually challenged persons inside the car and landings. Height of car operating panel& panel at landingshall beas per Harmonised guidelines for lifts issued by MOUD. |
| 33 | Intercom facilityLift car :- Inbuilt intercomReception & Lobby:1No each for lift passenger to speak with reception/ attendant with portability to connect with building inter come system |
| 34 | Visual floor indication shall be provided above the lift car door anda bove the landing doors. |
| 35 | Automatic phase reversal device and over voltage protection device. |
| 36 | Feature Dtetails :- Anti nuisance car call projection, idependent service (simplex), overload device, door nudging, emergency fireman's control switch, emergency car light unit, infrared curtain door projection, door time projection, emergency alaram button, extra door time of lobby & parking, belt/rope inspetion drive, auto fan cut off, audible car call button, door open/close button, manual rescue operation, belt/rope call projection, seimic sensor, automatic rescue operation voice synthesizer, pit ladder, intercom. All signal fixtures in stainless steel faceplates. |
| 37 | The prices of complete job as per the specifications above shall be inclusive of steel Items, minor Building work, Scaffolding etc. All sundry fittings, assemblies, accessories, Hardware items, foundation bolts, terminal lugs for electrical connections as required, and items which are useful and necessary for proper assembly and efficient working of various components shall be deemed to have been included in this job, whether such items are specifically mentioned in the tender documents or not including free service of one year.All rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax,sale tax Gst or other taxes as imposed by the Govt time to time where applicalble. |
| 38 | Supplying, Installation, Testing and Commissioning of 1 No minimum 13 passenger MRL traction elevator of with the following specifications with latest is 17900 code and features. Make :- KONE /OTIS / MITSUBISHI/TKE |
| 39 | Type and Capacity : 884Kg or better, 13 Passengers Minimum |
| 40 | Speed : 1.5/1.75 meter per second |
| 41 | Travel :- 34.5 mtr(approx.) (B1+B2+B3+M+3) 7 stops/7 openings |
| 42 | Controller : LVA/ACD |
| 43 | Serving:- 7 stop with all opening on all same side. |
| 44 | Hoist way Dimensions:-2250 MM W X 2650 MM D |
| 45 | Head Room Required :- 47 METER |
| 46 | PIT Depth:-1600 MM |
| 47 | CAR SIZE:-1600 MM Wx 1350 mm D x 2300 mm H) |
| 48 | CAR ENCLOSURE:- Constructed out of S.S. panels with Honey comb finish |
| 49 | CAR ENTRANCE:- Two speed slide side opening automatic S.S. panels in Honey comb finish with a clear opening |
| 50 | CAR & HOISTWAY DOOR TYPE:-Central opening power operated landing door in SS 1.5 MM Honey comb. |
| 51 | DOOR OPENING:-900 MM W X2100 H |
| 52 | DOOR OPERATION:- Automatic D.C. door operation with adjustable door opening & closing timing |
| 53 | POWER SUPPLY :- 400/415 Volts, 3 Phase, A.C. supply, 50 Hz |
| 54 | FAN :- 1 No with 300 mm sweep |
| 55 | FLOORING :- GRANITE |
| 56 | LIGHTING :- orange LED Illumination. |
| 57 | INDICATORS:- LED D & P Indicators in car . |
| 58 | Details :- |
| 59 | Motor compatible for 180 starts per hour. |
| 60 | Car operating panel with luminious floor button in car |
| 61 | Automatic Break Testing |
| 62 | Battery operated alarm bell and emergency light |
| 63 | Fireman's switch and fire rated door for 120 minutes. |
| 64 | Over load warning device Voice announcement . |
| 65 | Control panel on one side in the car and hall button panel at each landing with Stainless Steel (Hair line finish) |
| 66 | Automatic Rescue Device complete with dry maintenance free batteries as required |
| 67 | Hand rail on all thethree sides at 900mm above floor level to be fixed in the lift car. |
| 68 | Voice announcement system (English) in the car to announce the position of the elevator in the hoist way as the car passesor stops at each floors .These System should work during ARD operation also. |
| 69 | Braille buttons for visually challenged persons inside the car and landings. Height of car operating panel& panel at landingshall beas per Harmonised guidelines for lifts issued by MOUD. |
| 70 | Intercom facilityLift car :- Inbuilt intercomReception & Lobby:1No each for lift passenger to speak with reception/ attendant with portability to connect with building inter come system |
| 71 | Visual floor indication shall be provided above the lift car door anda bove the landing doors. |
| 72 | Automatic phase reversal device and over voltage protection device. |
| 73 | Feature Dtetails :- Anti nuisance car call projection, idependent service (simplex), overload device, door nudging, emergency fireman's control switch, emergency car light unit, infrared curtain door projection, door time projection, emergency alaram button, extra door time of lobby & parking, belt/rope inspetion drive, auto fan cut off, audible car call button, door open/close button, manual rescue operation, belt/rope call projection, seimic sensor, automatic rescue operation voice synthesizer, pit ladder, intercom. All signal fixtures in stainless steel faceplates. |
| 74 | The prices of complete job as per the specifications above shall be inclusive of steel Items, minor Building work, Scaffolding etc. All sundry fittings, assemblies, accessories, Hardware items, foundation bolts, terminal lugs for electrical connections as required, and items which are useful and necessary for proper assembly and efficient working of various components shall be deemed to have been included in this job, whether such items are specifically mentioned in the tender documents or not including free service of one year.All rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax,sale tax Gst or other taxes as imposed by the Govt time to time where applicalble. |
| 75 | Annual comprehensive maintenance of 2 Nos. 13/15 passenger MRL, 1.75 MPS, simplex automatic push button with/ without attendant lifts which include routine preventive and break down maintenance for a period of five years i/c repair/ replacement of worn out items with minimum down time replaced items i/c lamps, battery of ARD lighting system and over voltage protection device etc for five year. All rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax,sale tax Gst or other taxes as imposed by the Govt time to time where applicalble.Add for comperehensive maintenace for next consecutive year excluding the equipment with free warranty pariod of one year (For Second year) |
| 76 | (For Third year) |
| 77 | (For Fourth year) |
| 78 | (For Fifth year) Please Enable Macros to View BoQ information |