| 1 | M&L for removing unserviceable geyser 25/50 ltr capacity from any position after disconnecting the inlet and outlet connection transporting to reputed work shop and servicing the geyser by descaling, Soldering & brazing, replace the unserviceable items like rusted nut-bolts, screws, washers, rubber gaskets, fusible plug, neon indication lamps red & green, changing unserviceable heating element, thermostat, geyser base plate assembly, hot & cold PVC connections 450mm long etc and refixing the same with necessary nut, bolt, washers and making connection of inlet and outlet pipe and testing for smooth functioning after complete installation all as specified and directed.(Note : Soldering & brazing, replacement of Indicating lamps, Heating element, thermostat, Hot & Cold PVC will measured and paid separately under relevant items as supply only.) |
| 2 | Supply only heating element of 1.5 KW (Round or Triangular Head as required at site) including rubber washer (ISI marked) etc complete all as directed |
| 3 | Supply only heating element of 2.0 KW (Round or Triangular Head as required at site) including rubber washer (ISI marked) etc complete all as directed |
| 4 | Supply only auto cut thermostat of any type suitable for 25/50 Liter capacity Geyser, complete all as specified and directed. |
| 5 | Supply only indicator lamp (Red/ green) of any shape/ size as per existing pattern suitable for geysers of any capacity, complete all as specified and directed. |
| 6 | Supply only apparatus plate , including rubber washer to make leak proof suitable for water storage heater of 25 liter capacity complete all as specified and as directed. |
| 7 | Supply only apparatus plate , including rubber washer to make leak proof suitable for water storage heater of 50 liter capacity complete all as specified and as directed. |
| 8 | Supply only multi function safety valve PRV/ NRV for electric geyser of Cap 25/50 liter complete all as specified and as directed. |
| 9 | Supply only steel container suitable for Geyser 25 liter complete all as specified and as directed. |
| 10 | Supply only steel container suitable for Geyser 50 liter complete all as specified and as directed. |
| 11 | Supply only glass wool for insulation of tank as approved complete all as specified and as directed. |
| 12 | Supply only copper cable cord flexible 3 core PVC insulated and overall PVC sheathed of size 2.5 sqmm for making connection of geysers complete all as specified and as directed. |
| 13 | Supply only 24 inches long stainless steel braided flexible pipe suitable for hot & cold water supply with chromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet complete all as specified and as directed. |
| 14 | M&L Preparation of old surface of geyser (25 liter) in situ and applying one coat of synthetic enamel paint (Duco) using spray painting machine and writing MES No complete all as specified and as directed. |
| 15 | M&L Preparation of old surface of geyser (50 liter) in situ and applying one coat of synthetic enamel paint (Duco) using spray painting machine and writing MES No complete all as specified and as directed. |
| 16 | S&F in repairs, Single pole and neutral enclosure with a two pin and earth plug and socket including one single pole MCB 20 Amps , 240 V complete all as specified and directed. |
| 17 | S&F GI tubing 15 mm bore medium grade, with and including new fittings and fixed complete to walls and ceiling or laid in floors including taking out old tubing of any description complete all as specified and as directed. |
| 18 | S&F in repairs,multi function safety valve PRV/ NRV for electric geyser of Cap 25/50 liter complete all as specified and as directed. |
| 19 | Taking down exhaust fan of size 200mm to 300mm sweep of any make and transporting from any location to MES E/M store yard, and refixing on same location or other location carefully after repairing, washing by petrol ,greasing, replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) and testing the fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and as directed. |
| 20 | All as per item serial No 19 here-in-before but exhaust fans 300 mm sweep to 450 mm sweep complete all as specified and as directed. |
| 21 | Cutting the existing burnt copper winding of exhaust fan upto sweep of 200 to 300 mm and rewinding the armature with super enamelled copper wire of suitable size with and including all insulating materials varnishing including taking out burnt copper winding complete all as specified and directed.Note:- Replacement of defective/ unserviceable parts if required shall be measured and paid separately under respective items . |
| 22 | All as per item serial No 21 here-in-before but exhaust fans 380 mm sweep complete all as specified and as directed. |
| 23 | All as per item serial No 21 here-in-before but exhaust fans 450 mm sweep complete all as specified and as directed. |
| 24 | Supply only ball bearing suitable for exhaust fan 300 mm sweep complete all as specified and as directed. Make : NBC/SKF/SBBI |
| 25 | Supply only ball bearing suitable for exhaust fan 380/450 mm sweep complete all as specified and as directed(Make : NBC/SKF/SBBI) |
| 26 | Supply only bush bearing made out Gun metal suitable for any type/make of Exhaust fan complete all as specified and as directed. |
| 27 | Supply only condenser ISI marked 230/240/250 volts AC 4.0 Mfd suitable forexhaust fan complete all as specified and as directed.(Make : Usha/Asian/EPCOS/Universal). |
| 28 | S&F in repairs modular white cover plate with frame, 3 module complete all as specified and as directed. |
| 29 | S&F in repairs modular white cover plate with frame, 6 module complete all as specified and as directed. |
| 30 | S&F in repairs modular metal flush box, 3 module complete all as specified and as directed. |
| 31 | S&F in repairs modular metal flush box, 6 module complete all as specified and as directed. |
| 32 | S&F in repairs modular socket, 6A - 2/3 pin combined , 2 module complete all as specified and as directed. |
| 33 | S&F in repairs modular socket, 6A/16A - 2/3 pin combined , 2 module complete all as specified and as directed. |
| 34 | S&F in repairs modular switch 1 way 6A , 1 module complete all as specified and as directed. |
| 35 | S&F in repairs modular switch 1 way 16A , 1 module complete all as specified and as directed. |
| 36 | S&F in repairs, PVC ventilating fans AC single phase 230/ 240 V of size 250 mm sweep with louver shutter with frame and necessary fixing accessories , writing MES No. with black synthetic enamel paint 2 cm high in letter complete with necessary connection up including provision of three core copper flexible cable with flexible wire cover of plastic white in color and connection from ceiling rose to exhaust fan terminal etc complete all as specified and as directed.Make-Usha/Crompton/Bajaj Note : Old exhaust fan to be deposit to MES Store yard. |
| 37 | Supply and fix in repairs electric water heater, storage type PVC/steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc., complete all as specified and directed.Note: Old geyser to be deposited to MES store yard. |
| 38 | M & L for painting of exhaust fan complete with blades ,in situ with synthetic enamel paint Duco by spraying including filling cavities with filler ,ones coat after cleaning all dust etc.complete all as specified and as directed. |
| 39 | Supply and fix in repair heating element of 2.0 KW (Round or Triangular Head as required at site) including rubber washer (ISI marked) etc complete all as specified and directed. |
| 40 | Supply and fix in repair auto cut-off thermostat of any type suitable for 25/50 Liter capacity Geyser complete all as specified and directed.Make- Venus/Bajaj/Racold/Remson |
| 41 | S & F in repairs, switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 16 Amp flush type complete all as specified and as directed. |
| 42 | S & F in repairs, plug top with indicator 16 Amp flush type, complete all as specified and as directed. |
| 43 | Supply & Fix in repairs 24 inches PVC connection steel braided suitable for hot & cold water supply with chromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet complete all as specified and as directed. |
| 44 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, 16 sqmm one twin core cable flat or circular incl necessary connections incl taking down old one, complete all as specified and directed. |
| 45 | Supply and fixing in repairs LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Please Enable Macros to View BoQ information |