| 1 | Excavation in trenches, not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for water pipe line in soft/ loose soil, complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and wall remming in layers not exc 25 cm thick (soil), complete all as specified and directed. |
| 3 | Removing excavated material (soil) to a distance n.exc 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point, complete all as specified and directed. |
| 4 | Supply and laying of GI steel tubing 80 mm bore medium grade laid in tranches/wall/floor/on ground and joined including necessary fittings such as bends, flanges elbow, tees sockets , etc including necessary saddles and clamps including taking down old UNSV GI pipes, complete all as specified and directed. |
| 5 | Supply and laying of GI steel tubing 100 mm bore medium grade laid in tranches/wall/floor/on ground and joined including necessary fittings such as bends, flanges elbow, tees sockets , etc including necessary saddles and clamps including taking down old UNSV GI pipes, complete all as specified and directed. |
| 6 | Supply and laying of GI steel tubing 150 mm bore medium grade laid in tranches/wall/floor/on ground and joined including necessary fittings such as bends, flanges elbow, tees sockets , etc including necessary saddles and clamps including taking down old UNSV GI pipes, complete all as specified and directed. |
| 7 | Supply and laying of GI steel tubing 50 mm bore medium grade laid in tranches/wall/floor/on ground and joined including necessary fittings such as bends, elbow, tees sockets etc including necessary saddles and clamps including taking down old UNSV GI pipes, complete all as specified and directed. |
| 8 | Supply and laying of GI steel tubing 40 mm bore medium grade laid in tranches/wall/floor and joined including necessary fittings such as bends, elbow, tees sockets etc including necessary saddles and clamps including taking down old unserviceable GI pipe, complete all as specified and directed. |
| 9 | Supply and laying of GI steel tubing 25 mm bore medium grade laid in tranches/wall/floor/ and joined including necessary fittings such as bends, elbow, tees sockets etc including necessary saddles and clampsincluding taking down old unserviceable GI pipe, complete all as specified and directed. |
| 10 | Material and labour for cutting, drilling and taping cast iron / Ductile iron/ GI water mains (in position) for branch connection of the outer dia 80 to 150 mm including necessary fittings such as ferrules, nipple short pipe etc including taking down old UNSV GI pipes, complete all as specified and directed. |
| 11 | Supply and fix Valves,CI Sluice, flanged of class 1.0 PN, 150 mm (6”)dia complete with nut, bolt, washer and packing including taking down the old UNSV valve, complete all as specified and directed. |
| 12 | Supply and fix Valves,CI Sluice, flanged of class 1.0 PN, 100 mm (4”)dia complete with nut, bolt, washer and packing including taking down the old UNSV valve, complete all as specified and directed. |
| 13 | M&L for dismantling old valve chamber and construction of brick masonarry new valve pit chamber of size 900mm x 900mm x 900mm (internal ) size 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick built in CM 1:6 rendering in cement 1:6, 15mm thick finished even smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even supply and fix 3 mm thick MS sheet steel cover fixed on 50mmx50mmx4mm thick angle iron frame embbeded in PCC coping with locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron appplying two coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed steel surface making good all disturbed surface to match surrounding, complete all as specified and directed. |
| 14 | M&L for Angle iron work Suitable angle for frame work, cleats & similar work for Support of pipe Lines at sie etc, confirming to Fe - 290, grade E-165, fixed with necessary nuts, bolts, washers or welded attachment as required at site, complete all as specified and directed. |
| 15 | Supply and fix Valves, Sluice, flanged of class 1.0 PN, 80 mm (3”)dia complete with nut, bolt, washer and packing including taking down old unserviceable valve, complete all as specified and directed. |
| 16 | M & L Gun metal globe/gate valve (ISI Marked) with iron wheel head, screwed both ends for pipes or for unions for 50 mm bore dia steel tubing including taking down old unserviceable valve, complete all as specified and directed. |
| 17 | M & L Gun metal globe/gate valve (ISI Marked) with iron wheel head, screwed both ends for pipes or for unions for 40 mm bore dia steel tubing including taking down old unserviceable valve, complete all as specified and directed. |
| 18 | M & L for plain cement 1:3:6 type C -1 using 20mm graded stone aggregate in foundation of PCC poles/struts as specified including necessary form work, complete all as specified and directed. |
| 19 | M & L Gun metal globe/gate valve (ISI Marked) with iron wheel head, screwed both ends for pipes or for unions for 25 mm bore dia steel tubing including taking down old unserviceable valve, complete all as specified and directed. |
| 20 | Supply, laying and testing cable in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty), 1100 volts grade with stranded aluminium conductor of size 35sqmm, 3.5core, complete all as specified and directed. |
| 21 | M&L in replacement for FRP junction box of size 30 x 25x 15cm, four strip aluminium bus bar of capacity 63Amps mounted on epoxy insulators weather proof, MCB SP 6 Amps-01 No including provision for fixing to electric poles with 02 Nos, MS clamps of flat iron 40 x 6mm suitable size, complete with nuts & bolts making connection with calbe & including thimbles at suitable size, complete all as specified and directed. |
| 22 | S&F in replacement of LED street light fitting 90 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, prismatic polycarbonate cover with individual LED lenses with IP 66, complete with all accessories on pole at any height and removing old unserviceable street light fitting, complete all as specified and directed. |
| 23 | S&F in replacement PVC 3 core aluminium cable for connecting security lights to junction box of size 1.5sqmm, complete all as specified and directed. |
| 24 | S&F in replacement street light bracket made out of 32mm dia GI light grade pipe 1.2mtr long bend to shape 120 degree and duly fixed alongwith pole/ bldg with the help of 2 Nos of MS clamp of sizes 25 x 3mm FI including suitable size of bolt, nuts and washers, complete all as specified and directed. |
| 25 | M&L for sand cushioning to underground cable, provided with a layer 8cm before and 15cm after laying and stretching joining and testing the cable, complete all as specified & directed.Note: Punned thickness of sand shall be measured for payment purpose. |
| 26 | Supply & Laying brick covering with width equal to length of brick as mechanical protection to cable using sub class 'B' bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified & directed. Please Enable Macros to View BoQ information |