| 1 | Dismantling trellis work (Jafri) (One way), including taking as under of battens in trellis (posts and rails measured separately), complete all as specified and as directed. |
| 2 | Dismantling posts or struts (wood, steel or R.C.C.) embeded in cement concrete any section, including taking out embedded portion and making good disturbed ground, complete all as specified and as directed. |
| 3 | Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for including removal from site, complete all as specified and as directed. |
| 4 | M&L second class soft wood clean sawn as in scantling in framed and fixed work etc, complete all as specified and as directed. |
| 5 | S&F 2nd class softwood 35mm x 10mm laths (fixed straight or diagonally) in two way trellis work with 50mm spaces in the clear, including 75mm x 50 mm fillet (notched to take ends of laths) all round and fixed , complete all as specified and as directed. |
| 6 | M&L for preparation of newly or previously untreated wooden surfaces of any description, not otherwise described, over 10cm width or girth, applying two coats of synthetic varnish over a coat of thin varnish or lacquer or she llac varnish (filler coat), complete all as specified and as directed. |
| 7 | M&L for preparation of old treated surfaces of wood and wood based surface of any description not otherwise described over 10cm width or girth and applying one coat of synthetic varnish, complete all as specified and as directed. |
| 8 | M&L for preparation of old wooden surfaces of any description, not otherwise described, over 10cm width or girth, applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided for including fencing posts and struts, complete all as specified and as directed. |
| 10 | S&F angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed. |
| 11 | S&F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) including dismantling, complete all as specified and as directed. |
| 12 | S&F for 10 mm dia MS screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other ends or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm long and n.exc 10 cm long, complete all as specified and as directed. |
| 13 | Dismantling fencing wire mesh, any type, size and any position, complete all as specified and as directed. |
| 14 | Supply only chain link MS galvanised fecing any size or type, complete all as specified and as directed. |
| 15 | Fixing only chain link fencing including line wires, any mesh, size & type to any type of standards, rails, straining bolts etc including provison of binding wire, complete all as specified and as directed. |
| 16 | M&L Mild steel round bars 10mm dia and over cut to length bent to shape required including cranking, bending, spirally for hooping, columns hooking ends including binding with and including MS wire (annealed) not less than 0.9mm dia or securing nuts clips, Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde - E-165), complete all as specified and as directed. |
| 17 | S&F galvanised,corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with coach screw and washers in roofs, walls etc including dismantling, complete all as specified and as directed. |
| 18 | S&F Plain, galvanised, mild steel sheeting 0.80mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 fixed with coach screw and washers in roofs, walls etc including dismantling, complete all as specified and as directed. |
| 19 | S&F for Punched Tape concertina coil (incl spike and handle) with 50 turn and having a core wire(2.6+0.035 mm dia) are electro galvanised to provided protection against out door expose . The punched tape is machanically crimped over the core wire and the formed into a coil at various parts of the periphery of the coil steel clips total 129 nose per coil to each other so that it opens up like an accordion. Th width of strip as 19 mm and spacing be 15.2+5% kgs without packing material and coil length 12 mtr when opened up with an effective hight 600 mm. Each coil wound with bituminized hessain cloth for providing protective packing including dismantling complete all as specified and directed. |
| 20 | Excavation in post holes (or similar holes) each n.exc 0.5cum getting out, returing, filling in and raming earth/broken rubble mixed with earth around, in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50m and making good surface in soft/loose soil, complete all as specified and as directed. |
| 21 | M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed. |
| 22 | M&L for cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed. |
| 23 | Dismantling structural steel work including doors, gates but excluding framed truss etc, complete all as specified and as directed. |
| 24 | M&L for rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 (Gde E-165), complete all as specified and as directed. |
| 25 | M&L for preparation of newly or previously untreated steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 26 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed. |
| 27 | M & L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6, complete all as specified and as directed. |
| 28 | All as per Item No 27 above, but except stones, complete all as specified and as directed. |
| 29 | M&L for extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dresses surface not exc 40mm to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses for granite or trap stone, complete all as specified and as directed. |
| 30 | M&L for flush pointing to random rubble masonry, uncoursed or brought upto courses in cement mortar (1:4), complete all as specified and as directed. |
| 31 | M&L for raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:4, complete all as specified and as directed. |
| 32 | M & L for Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar (1:6), complete all as specified and as directed. |
| 33 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finishing the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 34 | M & L for preparation of newly plastered or unplastered surfaces of walls and applying three coats of white wash, complete all as specified and as directed. |
| 35 | M&L for providing cement concrete type C1, 1:3:6 (20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. |
| 36 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided, complete all as specified and as directed. |
| 37 | Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation, etc.or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 1.5m in depth and getting out in hard/dense soil, complete all as specified and as directed. |
| 38 | Returning, filling in,spreading, levelling, watering and well ramming in layers, not exceeding 25cm thick each, complete all as specified and as directed. |
| 39 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointand depositing where directed in soil, complete all as specified and as directed. |
| 40 | M&L for use & waste of fair finished flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter, complete all as specified and as directed. |
| 41 | M&L for use & waste of rough finished square, rectangular or polygonal formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and as directed. |
| 42 | M&L for reinforced cement concrete (nominal mix) type B1 1:2:4 (20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams: plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed. |
| 43 | M&L for reinforced cement concrete (nominal mix) type B1 1:2:4 (20mm graded stone aggregate) as in columns, pillars, piers, posts and struts, complete all as specified and as directed. |
| 44 | M & L for Mild Steel TMT bars 10 mm dia and over cut to length , bent to shape required , including cranking, bending spirally for hooping for column , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and as directed. |
| 45 | M & L for Mild Steel TMT bars 5 mm dia and over upto and including 10mm dia cut to length , bent to shape required , including cranking, bending spirally for hooping for column , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips in stirrups, spacers and binders, complete all as specified and as directed. |
| 46 | Note:- Schedule of credit Rs 1,16,625.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. Please Enable Macros to View BoQ information |