| 1 | Material Recovery Facility (MRF) |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Mechanical Means |
| 3 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means |
| 4 | Excavation for foundation in Soft rock and old cement or limemasonry foundation ncluding emoving eexcavated material upto adistance of 50 metres beyond the building rea and stacking as directed,including dewatering, preparing the bed for the foundation and ecessary backfilling with vailable earth/murum,ramming,watering including shoring and strutting etc.complete.(Liftfrom1.5mTo3.0m.)By Mechanical Means |
| 5 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. |
| 6 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 7 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. |
| 8 | Providing and laying Cast in situ/Ready Mix cement concrete M- 20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 9 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 10 | Providing and fixing in position TMT - FE - 500 bar Reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 11 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 12 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. |
| 13 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 14 | Providing and applying two coat softextured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary pre paring surface by thoroughly cleaning oil, grease,dirt and other materials as required, etc. complete. |
| 15 | Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. |
| 16 | Providing and laying in situ cement concrete M20 with tremix treatment for 100mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. |
| 17 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. |
| 18 | Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint) |
| 19 | ProvidingandfixingcolourcoatedZincalume(R)AZ150(min150gms/sq.mt.totaloneachside)profiledsheetsforroofing.Thefeedmaterialismanufacturedoutofnominal0.45mmBaseMetalThickness(BMT(0.5mmTCT),Histrengthsteelwithmin.550MPayieldstrength,metallichotdipcoatedwithAluminium-Zincalloy(55%aluminium43.4%zinc1.6%silicon)withCOLORBOND(Rsteelqualitysuperdurablepolyesterpaintcoat(withinorganicpigment).Thepaintshallhaveatotalcoatingthicknessofnominal35um,comprisingofnominal25umexteriorcoatontopsurface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050mmeffectivecoverwidthandnominal25-30mmdeepribswithsubtlesquareflutinginthefivepanatnominal180-250mmcenter-to-center.Theendribshallbedesignedforanti-capillarygroove.andreturnleg.Thefeedmaterialshouldhavecoilmanufacturersproductdetailsmarkedaregularinterval.Includingfastenerswithmin.fastenedwithmin.25umZinc-Tinalloycoated,Hexhead,self-drillingscrewetc.complete. (weight of profile 4.52 Kilogram/ One Square Metre) |
| 20 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) |
| 21 | Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.) |
| 22 | Providing and fixingweldedmesh of 11 gaugewires havingmesh size 50mmx 25mmincludingM.SAngleframeofsize35mmx35mmx5mminpositionwithoil painting 3 coats etc. complete |
| 23 | Providing and fixing of colour coated Zincaluminium( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated withAluminium-Zinc alloy (55% aluminiumm 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyster paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 mm, comprising of nominal 25mmexterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with sublet square fluting in the five pan at nominal 180-250 mmcenter- to-center. The end rib shall be designed for anti-capacity groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) 600 mm girth (Surface Width). |
| 24 | Shade Interanal Wair & Fittings Supplying and erecting mains with 3 x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking / inside pole / Bus bars or any other places as per specification No: WG-MA/BW |
| 25 | Supplying and erecting LED Panel Light (600mm X 600mm) Max. 30 having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty |
| 26 | Point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW |
| 27 | Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. OH- PL/STP |
| 28 | Making M- 20 grade reinforced cement concrete foundation by consideringthe safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply ofsteel, concrete, excavation, fixing provided nut bolts with the help of template,duly plastered as per design complete (for 3 to 5m octagonal / conical GIpole). |
| 29 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 30 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 31 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated shortcircuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB |
| 32 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short- circuitbreaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB |
| 33 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 34 | Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB |
| 35 | Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 36 | Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010 |
| 37 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG PW/CW |
| 38 | Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board. |
| 39 | Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board. |
| 40 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 41 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 42 | Baling Machine (10 HP)Machine shall be automatic and hydraulically operated with a 50-tonne pressing capacity force, capable of producing bales of size 810 mm × 610 mm × 750 mm ((32” x 24” x 30”) from a chamber of 810 mm × 610 mm × 1500 mm (32” x 24” x 60”), operating at 3000 PSI working pressure with a cycle time of 12–15 minutes per bale and bale weight of 100–150 kg. It shall have one pressing cylinder (110 mm piston thickness), side-door bale ejection, two doors, 8 mm body plate, 30 mm clamping plate, powder-coated structure, and overall size of approximately 4 ft × 3 ft × 8 ft.The machine shall be powered by a 10 HP, copper-wound AC induction motor, 3-phase 440 V, 50 Hz, with 120-litre oil tank and production capacity of about 2000 kg/day. It shall be suitable for baling PET, HDPE, LDPE, MLP, paper, clothes, and similar materials, conform to equivalent IS standards, and be supplied by a reputed manufacturer with dedicated push-button control panel and one-year free service with parts after commissioning. The quoted price shall be inclusive of transportation, unloading, erection, commissioning, packaging, forwarding, and insurance. |
| 43 | Plastic Shredding / Grinding Machine (25 HP)The plastic shredding machine shall be automatic and suitable for shredding and grinding all seven categories of plastic waste, including hard plastics such as PET, HDPE, and LDPE. The machine shall have a throat size of 24” × 14”–30”, fitted with 6 blades (4 rotor blades and 2 fixed blades) of size 18” × 5”, mounted on an equally balanced rotor shaft. It shall be capable of achieving a shredding capacity of 200–250 kg per hour, producing output particle size of 3–4 mm using a 13 mm mesh screen. The overall dimensions of the machine shall be approximately 56” × 72” × 60”, and the hopper shall be easily accessible for feeding material.The machine shall be powered by a 25 HP, 3-phase motor operating at 1440 RPM. The body shall be made of mild steel and cast iron, with cast iron pulley and balance wheel, and a mild steel stand. The machine shall conform to 1equivalent IS quality standards and be supplied by reputed and branded manufacturers, with the supplier providing detailed technical specifications of all accessories and |
| 44 | Fatka Machine (Plastic Cleaning with Air Blower)The Fatka Machine shall be designed for cleaning of all types of soft plastic waste using an air-blower mechanism. The machine shall have overall dimensions of approximately 8 ft × 6 ft × 4.5 ft and a weight of about 400 kg. The body shall be fabricated from 3 mm thick mild steel sheet. It shall have a production capacity of 150 kg per hour and shall be equipped with a rotor of 14-inch diameter and 6 ft length, fitted with 8 rotor rods. The machine shall include a 10 HP motor and a B-section pulley of 10-inch diameter, with suitable B-section belts, along with pedestal-type bearings for smooth operation.The opening mouth shall be covered with a 3-meter-long cloth arrangement to effectively collect cleaned plastic packaging material. All accessories and parts shall conform to equivalent IS quality standards, and the supplier shall provide detailed technical specifications of each accessory and component. Erection and commissioning, along with transportation, packaging, forwarding, insurance, and on-site training, shall be carried out by the supplier. Unloading charges, oil, and unskilled labour, if required during commissioning, shall be provided by the purchaser. The machine shall be supplied with one-year free after-sales service with spare parts after commissioning. Applicable taxes shall be clearly specified by the supplier. |
| 45 | Electronic Weighing Scale – 600 kg (Platform Type)The electronic weighing scale shall be of platform type with a maximum capacity of 600 kg and a platform size of 1000 mm × 1000 mm, fabricated from mild steel. The scale shall be equipped with a red LED display and shall operate on a 230 V power supply with a power consumption of approximately 10 watts. The weighing accuracy shall be ±60 grams, ensuring reliable measurement for material handling operations.The weighing scale shall include essential features such as tare facility, standard bi-directional RS-232 interface, battery backup of up to 12 hours, and inbuilt printing facility for receipt generation. The system shall be provided with overload and shock load protection for durability and safe operation. All components and accessories shall conform to relevant IS quality standards and be supplied by reputed manufacturers, suitable for use in waste management and material recovery facilities. |
| 46 | CO2 Fire Extinguisher - 4.5 Kg Capacity |
| 47 | ABC Fire Extinguisher - 9.0 Kg Capacity |
| 48 | Fire Bucket with Stand (4 Bucket) Please Enable Macros to View BoQ information |