| 1 | Supply and fix 90W LED street light CCT 5700K Luminous efficiency is 140 lumens/watt with dimming capability and enabled for GSM based individual control/ sensor based, 10KV external SPD, IP66, IK10 complete all as specified and as directed. |
| 2 | Supply and fix in repairs 2 runs of 1.5 sqmm, single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade and one run of 1.5 sqmm PVC multistranded copper conductor cable for earthing drawn through including non metallic PVC conduit not less than 20mm size with necessary conduit accessories etc as required and connected from fitting through the braket to DB sintex box complete all as specified and as directed by Engineer-in-Charge.Note : Two runs of 1.5 sqmm PVC insulated cable and one run of 1.5 sqmm cable and one run of PVC conduit shall be measured as one unit length. |
| 3 | Supply and fix in repairs GI pipe light grade of bore 50mm for cable protection, laid in trenches, or fixing on wall/ pole with help of suitable size MS clamp not less than 25 x 3mm strip complete all as specified and as directed. |
| 4 | Supply and fix in repairs hot press moulded SMC junction boxes, terminal box outdoor type, single hinged 25 x 25 x 15.5 cm, SMC door, with provision for cable incoming and outgoing from bottom, comprising of one MCB SP 6 Amp, including cable glands of suitable size and one bakelite connector four way fixed on wall/pole complete all as specified and as directed. |
| 5 | Supply and fix Prestressed concrete pole 9.0 metres long, 102x152mm at top and 102x289mm at bottom, class 10 complete dismantling and taking down existing pole etc complete all as specified and as directed. Note : Excavation & earth work, and concrete will be measured and paid separately under relevant items. |
| 6 | Material and labour for providing plain cement concrete 1:4:8, type D-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete including necessary form work etc. complete all as specified and as directed. |
| 7 | Material and labour for Plain Cement Concrete 1:3:6 type C-1, using 20mm graded stone aggregate as in coping including necessary form work and finishing to all exposed surfaces by using extra cement etc. complete all as specified and as directed. |
| 8 | Supply, lay, test and commissioning LT UG cable XLPE insulated armoured heavy duty electric cable 1100 volt grade with stranded aluminium conductor of cross sectional area 3.5/4 core AC supply including taking down/up existing LT UG cable etc complete all as specified and as directed of following sizes:- |
| 9 | Cable under ground LT 35 Sqmm 3.5 core. |
| 10 | Cable under ground LT 25 Sqmm 4.0 core |
| 11 | Cable under ground LT 16 Sqmm 4.0 core |
| 12 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for taking out/ laying of UG Cables, GI Pipe etc. and getting out in soft disintegrated rock/ laterite rock complete all as specified and as directed. |
| 13 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. |
| 14 | Removing excavated material to a distance not exceeding 50 m & depositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and as directed. |
| 15 | Supply and lay dry river sand or M sand in trenches for cable protection complete all as specified and as directed.Note : Punned thickness only will be measured and Paid separately. |
| 16 | Supply and lay cable cover LV type 1 flate size 250 X 150 X 40 mm for cable protection including taking down/up existing cable cover etc complete all as specified and as directed. |
| 17 | Material and labour for Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 m below ground level and connected to GI earth wire of size 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion including takingdown/up existing earth plate etc complete all as specified and as directed.Note: If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt. |
| 18 | Material and labour for Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 m below ground level and connected to GI strip of size 25x4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion including takingdown/up existing earth plate etc complete all as specified and as directed.Note: If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt. |
| 19 | Material and labour for Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 m below ground level and connected to GI strip of size 32x6 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion including takingdown/up existing earth plate etc complete all as specified and as directed.Note: If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt. |
| 20 | Material and labour for LT Panel board with CPRI APPROVED factory fabricated, TPN 415 Volts, 50 Hz, Bus bar of 200 Amps capacity placed horizontally throughout the width of Panel, outdoor cubical type floor mounted factory made double door dust and vermin proof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50 x 50 x 6 mm with height of legs is 0.75 m (0.3m under the ground) and 0.45m above ground with cable chamber for individual feeders for incoming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse, Voltmeter, Ammeter etc. complete all as specified and as directed with the followings Accessories :-INCOMING:-(a) CTs(b) Indicator lamp Set of 3(c) MCCB, 4 pole, 63 AMPS, 50 Hz, 415 Volt, 16 KA - 1 No(Incoming)(d) Digital Voltmeter & AmmeterOUTGOINGS:-(a) TPN MCB 32 AMPs, 50 Hz, 415 Volt, 10 KA-02 Nos(b) MCB SPN 40-63 Amps - 2 Nos(c) Nature time switch using infrared sensor technology 32 Amp with TP contractor 32 Amp -01 Nos |
| 21 | supply and fix in repairs Nature timer switch using infrared sensor technology based automatic street light control panel enclosed in SMC boxes with one nos MCB TPN 32amp, with contractor 32amp 3 pole connector 4 way 32 amps including fixing clamps, nut bolts etc. confirming to IP 54 complete all as specified and as directed. |
| 22 | Supply and fix in repairs single arm street light pole bracket made out of GI 40MM light grade bore pipe not less than 0.9M length bent to shape for fixing of street light fitting, Iron and two coats of aluminium paint over a coat of red oxide primer approved colour and quality including all accessories i.e. clamps, nut and bolts complete all as specified and as directed. |
| 23 | Supply and fix in repairs double arm street light pole top mounted, both side bracket type with two opposite direction arms from top (dual mounting arrangement) or as per site requirement made out of GI 40MM light grade bore pipe not less than 0.9M length for fixing of street light fitting, Iron and two coats of aluminium paint over a coat of red oxide primer approved colour and quality including all accessories i.e. clamps, nut and bolts complete all as specified and as directed. Please Enable Macros to View BoQ information |