| 1 | Civil WorksEarth work in excavation in ordinary rock by mechanical means (Hydraulic excavator) means over areas exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan including getting out and disposal of excavated material lead upto 50m and lift upto 1.5m all specified and as directed by Engineer-in-charge. |
| 2 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/disintegrated rock all as specified and as directed. |
| 3 | Excavation in trenches not exceeding 1.5m wide & not exceeding 1.5m in depth and getting out in soft/ disintegrated rock as in foundation and like etc complete all as specified and as directed. |
| 4 | Material and labour for sand filling under floors to receive paver block or in foundations including watering and consolidation complete all as specified and as directed |
| 5 | Material and labour for plain cement concrete 1:4:8, type D2 using 40mm graded stone aggregate as in 100 mm thick sub base/ flooring etc complete all as specified and as directed. |
| 6 | Material and labour for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 Grade with grey cement and pigment complete all as specified and as directed |
| 7 | Material and labour for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 8 | Material and labour for precast reinforced cement concrete 1:2:4, type B1 with using 20mm graded granite/ trap stone aggregate as in factory made cover slabs set in cement mortar 1:4 including form work etc complete all as specified and as directed.Note: Reinforcement shall be measured and paid separately |
| 9 | Material and labour TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 10 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 11 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed. |
| 12 | Demolition of brick work/stone masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, PCC coping etc., but excluding ashlar facings, dressed stonework and precast concrete articles and removing of debris outside MD land complete all as specified and as directed. |
| 13 | Material and labour for plain cement concrete 1:4:8 type D2 using 40mm graded aggregate as in foundation filling and mass concrete complete all as specified and directed |
| 14 | Material and labour for precast cement concrete block masonry with solid blocks made out of PCC 1:3:6, type C-1 with using 20mm graded stone aggregate, exceeding 10cm in width and setting in cement mortar 1:6 etc complete all as specified and as directed. |
| 15 | Material and labour for 15mm thick rendering with cement mortar 1:6 on brick or block masonry surfaces, finished the surfaces with even and smooth without using extra cement etc. complete all as specified and as directed. |
| 16 | Material and labour for preparing surfaces plastered or unplastered new surface of wall and applying two coats of cement based paint white or tinted over a coat of alkali resistant priming paint etc complete all as specified and as directed. |
| 17 | Material and labour for providing and fixing stainless steel benches (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement etc. complete all as specified and as directed. |
| 18 | E/M worksMaterial and labour for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire, armoured, heavy duty electric cables with stranded aluminium conductor of size 2 core x 10sqmm, 1100 volt grade, laid in trenches/ through GI Pipe/ fixed along with pole structure etc. complete all as specified and as directed.Note : Necessary earthwork, cable protection items shall be measured & paid separately under relevant items. |
| 19 | Supply and laying un-reinforced precast concrete cable cover, class LV, type1, flat, size 250 x 150 x 40mm in trenches for protection of UG Cable with width equal to length of PCC cover, laid dry & flat complete all as specified and as directed. |
| 20 | Supply and fix galvanised iron pipe medium grade of bore 40mm for cable protection, laid in trenches, under road or fixing on wall/ pole/ crossing drain/ nallah etc. complete all as specified and as directed. |
| 21 | Supply and fix 3 metres decorative with ring light, galvanised iron pole bottom dia 114mm, length 1000mm, thickness 3mm, galvanised iron pole top part dia 89mm, length 2000mm, thickness 3mm, mild steel base plate 250 x 250 x 10mm, aluminium casting embellishment as per drawing. The pole section should be welded by certified welders using high and MIG welding process. The service door shall be provided at bottom part of the pole to accommodate a built in connection box. The control gear tray is with MCB terminal connectors for loop in loop out arrangement. Pole shall be coated with epoxy zinc phosphate primer and finished using polyurethane base paint. 30 watt ring light post top, aluminium housing, milky diffuser IP 65, dia 4000mm, height 260mm complete all as specified and as directed. |
| 22 | Material and labour for sub main wiring complete with and including 3 runs of 1.5 sqmm, single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including non metallic PVC conduit of suitable size including accessories etc. as required and fixed on walls and 2 runs of 1.5 sqmm FRLS, PVC multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.Note : Three runs of 1.5 sqmm PVC insulated cable and Two runs of 1.5 sqmm cable and one run of PVC conduit shall be measured as one unit length. Please Enable Macros to View BoQ information |