| 1 | Wiring for light point / ceiling fan point /wall fan point including 6 amp 3 pin socket/call bell point / exhaust fan point with 1.5 sq mm FRLS /HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 sq mm,1.1 kV, FRLS/HFFR PVC insulated copper conductor single core cable etc as required. |
| 2 | Upto 6 metres ( Group A ) |
| 3 | Above 6 metres ( Group B ) |
| 4 | Above 9 metres ( Group C ) |
| 5 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required . |
| 6 | 2 X 1.5 sq mm + 1 X 1.5 sq mm for earth wire |
| 7 | 2 X 2.5 sq mm + 1 X 2.5 sq mm for earth wire |
| 8 | 2 X 4 sq mm + 1 X 4 sq mm for earth wire |
| 9 | 2 X 6 sq mm + 1 X 6 sq mm for earth wire |
| 10 | 2 X 10 sq mm + 1 X 6 sq mm for earth wire |
| 11 | 2 X 16 sq mm + 1 X 6 sq mm for earth wire |
| 12 | 4 X 4 sq mm + 2 X 4 sq mm for earth wire |
| 13 | 4 X 6 sq mm + 2 X 6 sq mm for earth wire |
| 14 | 4 X 10 sq mm + 2 X 6 sq mm for earth wire |
| 15 | 4 X 16 sq mm + 2 X 6 sq mm for earth wire |
| 16 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 17 | 20 mm |
| 18 | 25 mm |
| 19 | 40 mm |
| 20 | Supplying and drawing following sizes of FRLS/ HFFR PVC insulated 1.1 kV grade copper conductor single core cable in the existing surface /recessed steel / PVC conduit as required. |
| 21 | 2 X 1.5 sq mm +1 X 1.5 sq mm for E.C.C |
| 22 | 2 X 2.5 sq mm +1 X 2.5 sq mm for E.C.C |
| 23 | 2 X 4 sq mm +1 X 4.0 sq mm for E.C.C |
| 24 | 2 X 6 sq mm +1 X 6.0 sq mm for E.C.C |
| 25 | Supplying and fixing metal box/ Junction box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as require(ISI Approved). |
| 26 | 75 mm X 75 mm X 60 mm deep |
| 27 | 100 mm X 100 mm X 60 mm deep |
| 28 | 150 mm X 150 mm X 60 mm deep |
| 29 | Supplying and fixing following sizes/modules, GI / PVC box along with modular base & cover plate for modular switches in recess etc as required. |
| 30 | 1 or 2 Module (75 mm X 75 mm ) |
| 31 | 3 Module (100 mm X 75 mm ) |
| 32 | 4 Module (125 mm X 75 mm ) |
| 33 | 6 Module (200 mm X 77 mm ) |
| 34 | 8 Module (125 mm X 125 mm ) |
| 35 | 12 Module (200 mm X 150 mm ) |
| 36 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 37 | 5 /6 Amps Switch |
| 38 | 15 /16 Amps Switch |
| 39 | 3 pin 5 /6 Amps Socket Outlet |
| 40 | 6 pin 15 / 16 Amps Socket Outlet |
| 41 | Supplying and fixing Two Module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 42 | Supplying & fixing suitable size GI box/ PVC box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required with earthing attachment (Complete unit) for Split/Window Airconditioner. |
| 43 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 44 | Supplying and fixing 3 pin, 5 amp ceiling rose including 3 inch x 3 inch PVC box/ wooden block with connection etc as required. |
| 45 | Installation, testing and commissioning of pre- wired, fluorescent fitting /compact fluorescent fitting of all types complete with all accessories and tube etc. directly on false ceiling / wall including connection with 3 X1.5 sq mm FRLS PVC insulated copper conductor single core cable and earthing etc as required. |
| 46 | Installation, testing and commissioning of pre-wired,fluorescent fitting /compact fluorescent fitting of all types,complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement,2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with1.5 sq. mm FRLS/HFFR PVC insulated,copper conductor, single core cable and earthing etc. as required. |
| 47 | Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia. GI pipe(ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 3 X1.5 sq mm FRLS PVC insulated single core copper wire and making connections as required and mending good damages to wall & painting.( Light Fittings will be supplied by the Department). |
| 48 | Installation , testing and commissioning of wall fan/ ceiling fan including wiring the down rods of standard length (upto 30 cm ) with 3 X1.5 sq mm FRLS/HFFR PVC insulated copper conductor single core cable etc as required. |
| 49 | Supplying and fixing of extra conduit down rod of 20 cm Length (heavy gauge) GI pipe 15 mm dia wiring with 3 X 1.5 sq mm single core FRLS PVC cu cable including cutting, threading and painting etc as required.(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored.) |
| 50 | Installation of exhaust fan in the existing opening including of all hardwares & making good the damage connection, testing, commissioning etc. complete as required. |
| 51 | Upto 450 mm Sweep |
| 52 | Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. |
| 53 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on Wall Surface as required incl. S+F of 1 X 10 SWG rust free GI wire for E.C.C making holes and manding good the damages to original finish incl painting.( Cable Dept supply) |
| 54 | Upto 35 sq mm (rust free clamped with 1 mm thick rust free saddle) |
| 55 | Above 35 sq mm and upto 95 sq mm (rust free clamped with 25 X 3 mm rust free MS flat clamp) |
| 56 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on Cable Tray along with S+F of 10 SWG GI wire as earth wire as required. |
| 57 | Upto 35 sq. mm (clamped with 1mm thick saddle @ 3 sets per metre.) |
| 58 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25 X 3mm MS flat clamp @ 3 sets per metre.) |
| 59 | Laying of cable as below after Cutting Floor/Pavement/Wall and making holes incl embedding the cable at an average depth as below and mending good the damages to original finish incl S+F of 1 X 10 SWG wire for ECC (Cable Dept Supply) |
| 60 | From 2.5 sq mm to 35 sq mm at an average depth of 75 mm in floor/ pavement/wall etc. |
| 61 | Above 35 sq mm to 95 sq mm at an average depth of 100 mm in floor/ pavement/wall etc. |
| 62 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size Direct in Ground including excavation, sand cushioning, protective covering @ 8 bricks per metre on each cable and refilling the trench etc. as required. |
| 63 | Upto 35 sq. mm |
| 64 | Above 35 sq. mm and upto 95 sq. mm |
| 65 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing Masonary Open Duct incl mending good the damages to original finish. (Cable Dept Supply). This includes S+F 10 SWG GI earth wire for cables. |
| 66 | Upto 35 sq mm . |
| 67 | Above 35 sq. mm and upto 95 sq. mm |
| 68 | Supplying and making End Termination with brass compression gland and lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 69 | 2 X 6 sq mm (19 mm ) |
| 70 | 2 X 10 sq mm (19 mm ) |
| 71 | 2 X 16 sq mm ( 22 mm ) |
| 72 | 4 X 16 sq mm (28 mm ) |
| 73 | 3.5 X 25 sq mm (28 mm ) |
| 74 | 3.5 X 35 sq mm (32 mm ) |
| 75 | 3.5 X 50 sq mm (35 mm ) |
| 76 | 3.5 X 70 sq mm (38 mm ) |
| 77 | 3.5 X 95 sq mm (45 mm ) |
| 78 | Earthing with perporated GI Earth Pipe 4.5 mtr long, 40 mm dia including accesssories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. for any type of soil (Morrumed/boldered soil) with charcoal/coke,salt and also pouring of shifted loose soil as required and as instructed by the EIC. |
| 79 | Earthing with G.I. Earth Plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.for any type of soil (Morrumed/boldered soil) with charcoal/ coke and salt as required. |
| 80 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.All Joints should be done after 4\\"over lapping of the strips and by welding only. |
| 81 | Supplying and Fixing Earth Busbar of G.I.Flat 25 mm X 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on busbar complete with G.I. blots, nuts, washers, spacing heavy duty insulators etc as required. |
| 82 | Providing and fixing Hot dipped 6 SWG dia GI wire on surface or in recess for loop earthing as required. |
| 83 | Supply and Fixing medium gauge Gi pipe (ISI-Medium) protection for cable entry including bending the pipe to the required shape complete as required with laying of wire/cable through pipe. |
| 84 | 25 mm |
| 85 | 40 mm |
| 86 | Supplying and fixing DP sheet steel Enclosure on surface/recess along with 25/32 Amps,415 V \\"C\\" curve DP MCB complete with connection, testing and commissioning etc.as required. |
| 87 | Supplying and fixing TPN sheet steel Enclosure on surface/recess along with 16/25/32 Amps, 415 V \\"C\\" curve TPN MCB complete with connection, testing and commissioning etc.as required. |
| 88 | Supplying and Fixing DP/4P Sheet Steel Enclosure on surface/recess complete with connection,testing and commissioning etc.as required with out MCB/MCCB. |
| 89 | Two Pole Enclosure for MCB |
| 90 | Four Pole Enclosure for MCB |
| 91 | Four Pole Enclosure for MCCB |
| 92 | Supplying and fixing 20 Amps,240 Volt SPN Industrial type socket outlet,with 2 pole and earth, metal enclosed plug top alongwith 20 Amps,\\"C\\" curve,SP,MCB, in sheet steel enclosure, surface or in recess with chained metal cover for the socket out let and complete with connections,testing and commissioning etc,as required. |
| 93 | Dismantling of ceiling fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade,including cleaning of surface with detergent and replacing the damage rubber reel,nut and bolts with washers and safety pins capacitor, reinstalling the same etc. as required as per complaints given by Department. |
| 94 | Supplying and fixing 32 Amps,415 Volt TPN Industrial type socket outlet,with 4 pole and earth,metal enclosed plug top alongwith 32 Amps,\\"C\\" curve, TPN,MCB, in sheet steel enclosure,on surface or in recess with chained metal cover for the socket out let and plete with connections,testing and commissioning etc,as required. |
| 95 | Supplying and fixing 63 Amps,415 Volt TPN Industrial type socket outlet,with 4 pole and earth (3P +N+E+FP),metal enclosed plug top alongwith 63 Amps,\\"C\\" curve, TPN,MCB, in sheet steel enclosure,on surface or in recess with chained metal cover for the socket out let and complete with connections,testing and commissioning etc,as required. |
| 96 | Fixing only 240V SPN/415V TPN Sheet Steel Main Switch or DP/TP/FP sheet steel enclosure or SP/TP Industrial Plug,Socket directly on surface / recessed /on flat iron legs on wall along with required DP/TP/FP MCB including necessary connection, testing as required. (Enclosure/Main switch / Industrial Socket : Department supply ). |
| 97 | Supplying and fixing following way, Single Pole and Neutral, IP- 43, sheet steel, MCB distribution board, 240 V /415 V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 98 | 6 Way , Double door |
| 99 | 8 Way , Double door |
| 100 | 12 Way Double door |
| 101 | Supplying and fixing of following ways surface/ recess mounting, Horizontal type, IP-43,415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 Amps, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. |
| 102 | 4 Way (4 + 12), Double door |
| 103 | 6 Way (4 + 18), Double door |
| 104 | 8 Way (4 + 24), Double door |
| 105 | Supplying and fixing of following ways surface/ recess mounting, Vertical Type,IP-43, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 Amps, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TP DB is normally used where 3 phase outlets are required.) |
| 106 | 4 Way (4 + 12), Double door |
| 107 | 8 Way (4 + 24), Double door |
| 108 | 12 Way (4 + 36), Double door |
| 109 | Supplying and fixing of following ways surface/ recess mounting double door Vertical TPN MCB Distribution board for MCCB Incomer IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provisionfor earthing attachment Up to 160A . |
| 110 | 4 Way Double door |
| 111 | 8 Way Double door |
| 112 | 12 Way Double door |
| 113 | Fixing only of followings DB/SFU unit directly on surface / recessed /on flat iron legs on wall including necessary connection etc. as required. ( DBs/ switch fuse unit : Department supply ). |
| 114 | SPN MCB DB (4 to 16 way) |
| 115 | TPN MCB DB (4 to 12 way) |
| 116 | Supplying and fixing 5 Amps to 32 Amps rating, 240/415 V,10 kA,“C” curve, Miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 117 | Single Pole |
| 118 | Double Pole |
| 119 | Triple Pole |
| 120 | Triple Pole and Neutral |
| 121 | Supplying and fixing 40 Amps to 63Amps rating, 240/415 V,10 kA,“C”curve, Miniature Circuit breaker suitable for inductive load of following poles in the existing MCB DB or in enclosure complete with connections, testing and commissioning etc. as required. |
| 122 | Single Pole |
| 123 | Double Pole |
| 124 | Triple Pole |
| 125 | Four Pole |
| 126 | Supplying and fixing 100 Amps rating, 240/415 V, 10 kA, “C” curve, Miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB or in enclosure complete with connections, testing and commissioning etc. as required. |
| 127 | TriplePole |
| 128 | Four Pole |
| 129 | Providing and fixing of following rating and breaking capacity and pole MCCB (Molded Case Circuit Breaker) with thermomagnetic release and two sets terminal spreaders in the existing cubical Panel board /MCCB DB/Enclosure including drilling holes, making connections, Ics = 100% Icu and Operational Voltage 690 V etc. as required. |
| 130 | 100 Amp, 30KA Four Pole |
| 131 | 125 Amps, 36KA Four Pole |
| 132 | 200 Amps, 36KA Four Pole |
| 133 | 250 Amps,36KA Four Pole |
| 134 | Supplying and fixing 240/415 V Change Over Switch ( MCB module) on din rail of existing DBs/enclosure box and necessary connection as required. |
| 135 | Double pole 40 Amp |
| 136 | Double pole 63 Amp |
| 137 | Four pole 40 Amp |
| 138 | Four pole 63 Amp |
| 139 | Fixing only exhaust fan making hole in wall and making good damages and smooth cement finish etc.as practicable as possible and providing necy length of PVC insulated wire and making connection for exhaust fan for 30 cm(12 inch) Sweep. |
| 140 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, GI tube, having single prong at top, with 85 mm dia 6 mm thick GI base plate including holes etc, complete as required |
| 141 | Providing and fixing GI tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 142 | Providing and fixing GI tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.( For Vertical run) |
| 143 | Providing and fixing testing joint, made of 20 mm X 3 mm thick GI strip,125 mm long, with 4 nos rust free GI bolts, nuts,check nuts and spring washers etc,complete as required . |
| 144 | Filling available excavated earth (excluding rock) in trenches/ sides of earthing foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, within lead up to 50 metres including the cost of carried earth. |
| 145 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 146 | 2 X 16 sq. mm |
| 147 | 3½ X 25 sq. mm / 3½ X 35 sq. mm / 3½ X 50 sq. mm |
| 148 | 3½ X 70 sq. mm |
| 149 | 3½ X 95 sq. mm |
| 150 | Supplying & Fixing of AC Controller having 01 No. 6 way SPN double door DB including 02 Nos. 25 Amp. 2 N/O Contactor equivalent to Hager Cat No.- ESC 225 and 1 No. FM-1 - Quart Daily Time clock 110 VAC Base on the Din Mounting equivalent to Hager Cat No. - EH 111 and internal wiring with 4 sq mm circuit including connection with Existing AC unit, painting etc.as required. |
| 151 | Supplying & Fixing of FM-1 Quartz Daily Time clock 110 VAC Base on the Din Mounting (equivalent to Hager Cat No. - EH 111) in existing AC controller unit. |
| 152 | Supplying & Fixing of 25 Amp 2 N/O Contractor (equivalent to Hager Cat No.- ESC 225) in the existing AC controller unit. |
| 153 | Fixing of LED Batten Tube Light/ Outside LED Light/LED downlight / 2X2 ft. Panel Light on the existing Light Point/ fixture as per complaints given by Departments etc. as required as per instructions by EIC. (Light fittings & accessories : Department supply). |
| 154 | Supply, Installation, Testing and Commissioning of Ceiling fan with Brush Less Direct Current (BLDC) Motor with copper winding, Class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, Steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374 -2019), THD (Total Harmonic Distortion) less than 10%, Suitable for operation with electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, Ceiling Fan Complaint to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 155 | 1200 mm sweep, Service Value (CM/Min/Watt ) minimum 6.00, Air delivery 210 CM/Min( Minimum) |
| 156 | 1400 mm sweep, Service Value (CM/Min/Watt ) minimum 6.00, Air delivery 245 CM/Min( Minimum) |
| 157 | LED Panel Light 2X2 ft. (System lumen efficacy>= 120 to <135 lm/Watt) :- Supplying, Installation, Testing & Commissioning of Panel light 2 ft X 2 ft, of Powder Coated CRCA Sheet Body (Thickness>=0.50 mm) materials and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85% Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 degree C to 40 degree C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 158 | 36 watt |
| 159 | 40 watt |
| 160 | LED Batten light (System lumen efficacy ≥105 to <120 lm/Watt) :- Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of Powder Coated CRCA Sheet Body (Thickness>=0.50 mm) material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 - 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be mitted. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 161 | 18 - 22 watt |
| 162 | 24 - 26 watt |
| 163 | Supply, Installation, Testing and Commissioning of 220 - 240 volt a.c., 50 HZ, single phase Input Voltage, 400 mm Sweep Wall Mounted Fan complete with Pull-Cord mechanism for speed control & oscillation and all accessories of the following Specification :- White in colour, Power consumption = 60 Watt, Speed =1350 RPM, Air delivery >/= 80 CMM and connection with 3X1.5 sq mm FRLS PVC insulated copper conductor single core cable and earthing etc as required. |
| 164 | Supply, Installation, Testing and Commissioning of 250 mm Sweep, 220 - 240 volt, a.c., 50 HZ, Single phase, Plastic Ventilating Fan complete with dust protection shutter & all accessories of the following specification :- Power Input =/ < 40 Watts, Speed = /< 1300 RPM, Air Delivery = /> 750 CMH and mounting with grouted frame/ clamp arrangements with necessary accessories & Connection with mending good to the damages. |
| 165 | Dismantling of following items with good condition and shifting to site store etc. including mending good the damages to original finish etc. as required as per instructions by the EIC. |
| 166 | Light Fittings/ Ceiling Fan/ Wall Fan/ Exhaust Fan/ Modular Power Board with switch & socket etc. including accessories, old wiring & cable. |
| 167 | SPN DB/ Main switch/ Industrial plug & socket DB/ Metal Enclosure/ TPN MCB DB etc. including accessories, old cable & wiring. |
| 168 | VTPN MCCB DB/ Small Size Power Supply Panel etc. including accessories, old cable & wiring. |
| 169 | Supply and fixing of PCB unit of BLDC fan of fixed regulator type of existing fitted Havells/Atomberg/Cropmton/Orient make BLDC fan with one year on site replacement Warranty. |
| 170 | Supply and replacing of damaged stator assembly complete unit of existing fitted Havells/Atomberg/Crompton/Orient make BLDC fan (fixed regulator type) with one year on site replacement warranty. |
| 171 | Supplying and replacing of following sizes of faulty Capacitor of metal body in the existing Fan. |
| 172 | Capacitor of 1.5 MFD |
| 173 | Capacitor of 2.0 MFD |
| 174 | Capacitor of 2.25 MFD |
| 175 | Capacitor of 2.5 MFD |
| 176 | Capacitor of 3.15 MFD |
| 177 | Capacitor of 4.0 MFD |
| 178 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 179 | Attending \\"No Power\\" complaint with replacement of MCB/MCCB of any pole ( SP/ DP/TP/ FP) in Academic area. This includes disconnecting and dismantling the old items and depositing them to store. (All material will be supplied by the deptt.) |
| 180 | To attend emergency complaints/ DG sets Look after by One Skilled and One Semiskilled Technician in office working hours or any Shift duty hours or any other task as assigned by EIC/SIC etc. in complete as required (Daily 8 hrs). |
| 181 | Complete rewinding of faulty fans of following sizes as per standard code of practice with approved make SWG GR-1 super enamelled copper wire with overhauling and servicing by applying new grease to the bearing, oil seal cleaning & oiling, replacement of bushes and shafts, nuts & bolts,safety pin, insulator, flexible wire etc as required with one year on site replacement Warranty. |
| 182 | Ceiling fan (48\\") |
| 183 | Ceiling fan (56\\") |
| 184 | Exhaust fan (10\\") |
| 185 | Exhaust fan (12\\") |
| 186 | Exhaust fan (15\\") |
| 187 | Exhaust fan (18\\") |
| 188 | Exhaust fan (24\\") |
| 189 | Wall fan (16\\") |
| 190 | Air circulater Wall fan (24\\") Please Enable Macros to View BoQ information |