Name of Work:- Parovding and laying of Under ground cabel at malka prole to ramgadh by pass
Sl. No.
Item Description
1
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR10.0 Sq. mm 4 core
2
P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .50 mm
3
Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .10.0 Sq.mm
4
Supply installation testing & commissioning of IK10 & IP65 3 phase 440V 50Hz , 7.5kw capacity centralized control and monitoring system panel (CCMS) made of fire retardent SMC steel material having lock system suitable for schedule on/off of Led & garden lights having following provision: *Dedicated control & metering unit. * pre programmed on/off schedule& remote on/off operation in case of bad weather/emergency /maintenance.Bypass faciltiy per phase. *Data capture of Energy consumption & other electrical data in real time & at pre deterimned interval. *RTC controller should be type tested in NABL approved lab & should be compitable with communication module 2G/4G which transmit data wirelessley and recorded to dedicated server or on cloud based architecture and aslo give command for schedule on/off of cluster of lights. Latiching relay/Bi-stable switch/isolation device should conferming to IEC-61-36/61037 & contactor also conferming to relevant IEC/IS standard13779.MCB conferming to IEC-62053/62054.With included pipe earthing as per IS:3043-1987 *Controller also have functional specification is for A) Lux sensor & Astronomical Clock mode :- 1)For switching ON---- < 60 lux for >30 sec or Twilight Duskwhichever is later 2)For switching OFF--->10 lux for >30 sec OR twilight Dawn whichever is earlier and B) for time schedule mode --- For switching ON/OFF---Time selected by user *Controller should connected to separate lithium battery to provide back up of minimum 8 hours in case of power outage. * unit should be supported by web/app based software package with detail information dashboard. * pole mounting/surface mounting stand. *inclusive of 2 year server & website hosting charges. Comprehensive on-site warranty of above Central Control & Monitoring System (CCMS)- Street Light Controller including SIM card or any other maintenance charges for 2 years.
5
P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as reqd. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Up to 380 mm size
6
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users