| 1 | M&L for site clearence in soft / loose soil including cleaning away all grass, vegetation, sapling, shrubs, brushwood, undergrowth, roots and trees not exceeding 30cm girth (measured one meter above ground level) and removing rubbish up to a distance of 50 m outside the periphery complete all as specified and directed. |
| 2 | Surface excavation n exc 30 cm deep & avg 15 cm and getting out in hard / dense soil complete all as directed. |
| 3 | Excavating over areas, n exc 1.5m deep & getting out in hard / dense soil complete all as directed. |
| 4 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in hard/dense soil complete all as specified and directed. |
| 5 | M & L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 6 | M&L for hard core of broken stone or boulder, gauge n exc 63mm deposited spread and leveled in layers n exc 15cm thick watered and rammed to a true surfaces complete all as specified and directed. |
| 7 | PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in foundation for post and similar work complete all as specified and directed. |
| 8 | M & L for 100 mm thick PCC 1:4:8, type D2, (using 40mm graded stone aggregate) as in sub- base floor finished the surface fair and rough to receive subsequent layer with and including necessary formwork complete all as specified and as directed. |
| 9 | M & L for 100 mm thick, plain cement concrete 1:2:4, type B-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 including necessary formwork complete all as specified and directed. |
| 10 | M & L for rendering 15 mm thick cement plastering on wall surfaces in two layers (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 11 | Supply only liquid water proofing compound complete all as specified and directed. |
| 12 | Returning filling in including spreading leveling watering and well ramming in layers n exc 25cm complete all as specified and directed. |
| 13 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point (Soils) complete all as specified and directed. |
| 14 | S&F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 15 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrom primer, complete all as specified and directed. |
| 16 | S&F mild steel galvanised PVC coated chain link fencing, 3.15 mm nominal dia of GI wire, 1.4 mm thick PVC coating and average area of aperatus 25 sqcm with weight of chain link not less than 3.00 Kg / Sqm complete all as specified and directed. |
| 17 | S&F mild nylon protective, knotless type, UV stabilized, mesh size 40mm x 40mm, twine thickness minimum 2.5 mm, fixed with GI wire to MS / GI frame work including all fitting, cutting tying, tensioning complete all as specified and directed. |
| 18 | S&F of 20 mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete all as specified and as directed. |
| 19 | S & F 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all complete all as specified and directed. . |
| 20 | Supply, installation, testing and commissioning of pop up spray head, 4\\" (102mm) pop up height, , full circle 360 degree, dual spray pattern nozzle, with 1/2 \\" FNPT inlet, adjustable spray radious 8-15 ft, operating pressure 15-70 psi, UV resistant, plastic body with stainless steel spring, pressure activated wiper seal, ratcheting mechanism for alignment and removable top serviceable internal parts including all accessories, necessary excavation, connection to lateral line, flushing commissioning and making good complete all as specified and directed.(Make: Model No.1804 FDS of Rain Bird / Model No. PROS-04-CV of Hunter / Model No. PRO-S of K-Rain or as approved by GE.) |
| 21 | Supply, installation, testing and commissioning of submersible pump set 3.00 HP, single phase, water cooled, suitable for continious duty operation on 180-240 volts supply having cast iron body, dynamically balanced impeller, stainless steel shaft with bearings, capable of delivering discharge upto 100LPM against head 20-40 m, with and including suitable control panel for off on (DOL starter), submercible power cable ( 2.50 Sqmm flat Three Core PVC Insulated & PVC Sheathed Industrial Cable for Submersible pump Motors 1100 Volt, conforming to IS 694, Minimum length shall be 10 M.) fixing arrangements, electrical connections including making good disturbed surfaces complete all as specified and directed. |
| 22 | Supply, installation, testing and commissioning of central foam jet fountain nozzle, heavy duty, stainless steel / brass, corrosion resistant, 1\\" BSP connection, design to deliver a stable, frothy water column of 2.5-3 m height, operating pressure 1.50 - 3.00 bar, suitable for outdoor decorative fountain in the centre of locations including necessary flow straightner, clamps, piping alignment, connection to pump by all electrical connection including making good disturbed surfaces complete all as specified and directed. |
| 23 | M & L for 75 mm thick PCC 1:4:8, type D2, (using 40mm graded stone aggregate) as in sub- base floor finished the surface fair and rough to receive subsequent layer with and including necessary formwork complete all as specified and as directed. |
| 24 | M & L Machine pressed precast concrete interlocking paver block any shape prepared with grey cement and pigment of size confirming to IS 15658-2006 of 60 mm thick M-35 Grade laid over sand cushioning layer complete all specified and directed. (Note: Sand cushioning shall be measured and paid in relevant item.) |
| 25 | M&L for sand filling under floors or in foundations including watering and consolidation for cushioning complete all as specified and as directed. |
| 26 | M & L for 75 mm thick PCC 1:3:6, type C2, (using 40mm graded stone aggregate) as in base of kerbstone and including necessary formwork complete all as specified and as directed. |
| 27 | M&L Stone kerb of machine pressed rubber moulded precast cement concrete of M-25 grade , using 20mm graded stone aggregate, block of size 45cmX30cmX15cm finished at top bullnosed shape and finished surface even and smooth using coloured pigment and jointed in CM 1:3 struck finished as directed. |
| 28 | S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches complete all as specified and as directed. |
| 29 | M&L for preparing the concrete surfaces of kerb stone applying two coats of synthetic enemel paints in zebra pattern over a coat of primer complete all as specified and as directed. |
| 30 | M&L for precast cement concrete block masonary exc. 10 cm width with solid block of PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and stting in CM 1:4 complete all as specified and as directed. |
| 31 | M&L for 18 to 20 mm thick granite (of any type and colour) tiles machine cut as in floors jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing with and including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.(Note: The colour / shade / design of granite shall be as approved by GE(I).) |
| 32 | M&L for preparing new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic exterior emulsion paint having VOC less than 50 m/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including one priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces as ecommended by the manufacturer all as specified and as directed (Note : Rate shall be included for necessary scaffolding and safety measures where required at site ). |
| 33 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 34 | M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:3 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 35 | Supply, plantation and developing of carpet Grass including necessary earthwork and excavation to achieve a depth of 30 cm in any type of soil, removing the roots and vegetation and filling of the excavated area with good earth (red soil) mixing with cow dung and vermi compost and watering etc and applying soil pesticide complete all as specified.Notes: (i)Layout plan for lawn/plants/hedges/grass shall be submitted and get its approval from GE (I) before the execution of respective items.(ii) Cost of manure, good soil, pesticides etc. shall be measured and paid separately under relevant items. |
| 36 | Supply only approved loose soil best quality for plantation |
| 37 | Supply only approved manure (cow dung) best quality |
| 38 | Supply only approved vermi compost best quality |
| 39 | Supply and plantation of Royal palm (height of plant not less than 10 feet above ground level) incl preparation of ground up to 30cm deep and filling of good earth, cow dung vermi compost and watering etc. complete all as directed by the Engineer-in-charge.Note: (i)Layout plan for lawn/plants/hedges/grass shall be submitted and get its approval from GE (I) before the execution of respective items.(ii) Cost of manure, good soil, pesticides etc. shall be measured and paid separately under relevant items. |
| 40 | Supply and plantation of Temple Tree (height of plant not less than 10 feet above ground level) incl preparation of ground up to 30cm deep and filling of good earth, cow dung vermi compost and watering etc. complete all as directed by the Engineer-in-charge.Note: (i)Layout plan for lawn/plants/hedges/grass shall be submitted and get its approval from GE (I) before the execution of respective items.(ii) Cost of manure, good soil, pesticides etc. shall be measured and paid separately under relevant items. |
| 41 | (Note for Serial item No. 35, 39 & 40: During defect liability period contractor shall look after the plants / tree by deputing one malli , who will watering the plants / tree, provide manure if requirred , loosing the earth near root of tree as requirred without any extra cost to the Govt.) Please Enable Macros to View BoQ information |