| 1 | Demolition cement concrete (unreinforced) in ground floor and pavings not exceeding 15cm thickness below or above ground level with and including removing rubbish material from building and thrown in low lying empty area complete all as specified and directed by Engineer-in-charge. |
| 2 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in Soft/ Loose soil complete all as specified and as directed by Engineer-in- charge. |
| 3 | Material & Labour for Hardcore of broken stone or boulders ,gauge exceeding 63mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge. |
| 4 | Material and labour for Cement Concrete 1:4:8 , Type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge. |
| 5 | Material and labour for RCC M-25 (Design mix) using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. |
| 6 | Material and labour for RCC M-25 (Design mix) using 20 mm graded stone aggregates as in columns, pillars, piers, posts and struts complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. |
| 7 | Material and labour for RCC M-25 (Design mix) using 20 mm graded stone aggregates as in beams, cantilevers, bressummers, lintels over 1.5 m span and the like etc complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. |
| 8 | Material and labour for RCC M-25 (Design mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like and in chajja etc complete all as specified and as directed by Engineer-in-charge.NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. |
| 9 | Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia including making of rungs, handles etc complete all as specified and as directed by Engineer-in-charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.) |
| 10 | Material and labour for Mild steel TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders etc. cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips directed by Engineer-in-charge.(NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.) |
| 11 | Material and Labour for Formwork of sides of concrete foundations, Footings, Bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter on rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge. |
| 12 | Material and Labour for Formwork in square,reactangular or polygonal on rough finished surface of concrete to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed by Engineer-in-charge. |
| 13 | Material and labour for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. on rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge. |
| 14 | Material and labour for Formwork to soffits of suspended slabs such as roof slab, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) on rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge. |
| 15 | Material and Labour Brick work with sub class ‘B’ burnt clay old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed by Engineer-in- charge. |
| 16 | Material and labour for Brick work with sub class ‘B’ burnt clay old size bricks, straight or curved on plan to any radius in half brick walls built in Cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge. |
| 17 | Material & Labour for 100 mm thick PCC 1:4:8 ,Type-D2 ,using 40mm graded stone aggregates as in sub base of flooring complete all as specified and directed by Engineer-in-Charge. |
| 18 | Material and labour for 75 mm thick PCC (1:3:6) Type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection / path etc. finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge |
| 19 | Material & Labour for Rendering 15mm thick in Cement Mortar 1:4 using liquid waterproofing compound as per manufacturer instruction on fair faces of brick work or concrete surfaces of wall finished even and smooth with out using extra cement complete all as specified and as directed by Engineer-in-Charge. Note:- Liquid Water proofing compound shall be measured and paid separately under appropriate item of Schedule'A' BoQ. |
| 20 | Material and labour for Rendering 10mm thick in Cement Mortar 1:6 , on fair faces of brick work or concrete surfaces, finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply only liquid water proofing compound complete all as specified and directed by Engineer-in-Charge. |
| 22 | Material & Labour for Non skid ceramic coloured tiles , thickness 7mm to 8mm thick (square/ rectangular), colour as approved by Engineer-in-charge area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured cement to match the colour / shade of tiles , laid over with and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 23 | Material & Labour for Glazed ceramic coloured tiles size 350mm x 250mm / 450mm x 300mm x 7mm to 8mm thick as in verticle surface , set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured cement to match the colour / shade of tiles , laid over with and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 24 | Material and labour for preparation of new surface of walls, with and including two coats of cement base paint ,over with and including one coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge. |
| 25 | Material and labour for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge. |
| 26 | Supply & Fixing Mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) Fe 410 -W (Gde- E- 250) quality-A including distance pieces, cleats etc. complete all as speicied and as directed by Engineer in charge. |
| 27 | Supply & Fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply & Fixing Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engineer-in-Charge. |
| 29 | Material & Labour for preparation of newely steel surfaces of any description, over 10 cm in width or girth or otherwise described , with and including applying two coat of syntheic enamal paint over with and including one coat of red oxide zinc chrome primer complete all as spefied and as directed by Engineer-in-Charge. |
| 30 | Supply and Fixing Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed by Engineer-in-Charge. |
| 31 | Material and Labour for 3mm thick Figured glass, pin head type and glazing with oil putty in squares not exceeding 0.50 sq. m in each pane complete all as spd and directed by Engr-In-Charge . |
| 32 | Supply & Fixing Solid PVC door frame of size 50mm x 47mm made out of 5 mm single side prelam PVC sheet reinforced with MS square tube manufactured as per SSR Part-I specifications and drawings complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply & Fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply and Fixing butt hinges size of 100mm , medium weight cold rolled mild steel complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply and Fixing 150mm longh aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge. |
| 36 | Supply and fixing 150mm aluminium handle cast type, anodised, complete all as specified and directed by Engineer-in-Charge. |
| 37 | Removing excavated material of any type of soil not exceeding 50m and depositing where directed at a level n exc 1.5 mtr above the starting point . complete all as specified and directed by Engr- in- charge. |
| 38 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, in any type of soil complete all as spefied and as directed by Engineer-in-Charge. |
| 39 | Supply and Fixing vitreous china wash down water closet pan ( pedestal pattern ) white , with and including stainless steel Jet , with and including ‘P’ or ‘S’ trap , with and including seat cover complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply & Fixing water closet vitreous china squatting pan, Orissa pattern size 580mm x 440mm white with integral foot rests with and including provision of lime concrete bedding with and including `P' trap and connection to drain and to flushing pipe anti symphonage pipe complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply and Fixing PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle , with and including brackets, with and including 32 mm dia flush pipe of polyethylene of low or high density of PVC complete all as specified and as directed by Engineer-in- charge. |
| 42 | Supply & Fixing vitreous china wash hand basins size 550mm x 400 mm ovel type with Mild steel brackets, with and including cutting for and pinning in ends of brackets or erecting stand, with and including waste fittings of brass chromium plated ,with and including 32mm dia PVC waste pipe of required length complete all as specified and directed. as directed by Engineer-in-Charge. |
| 43 | Supply & Fixing Vitreous China bowl urinal flat back, size of 430mm x 370mm x 340 mm white (minimum), with grating and union for discharge pipe with and including 32mm bore PVC waste pipe complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply and Fixing 15mm bore Pillar tap fancy type Chromium Plated , cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 45 | Supply and fixing 15mm bore bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge. |
| 46 | Supply and fixing 15 mm bore stop valve chromium plated with long shank and cup ( concealed type) , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge. |
| 47 | Supply and Fixing PVC connection 15 mm size PTMT nuts of length 600 mm complete all as specified and directed by Engineer-in-Charge |
| 48 | Supply and Fixing soap dish vitreous china white of size 160mm x 160mm x 90mm complete all as specified and as directed by Engineer -in-Charge. |
| 49 | Supply & Fixing 15mm bore GI tubing medium grade with all new fittings to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge. |
| 50 | Supply & Fixing 20mm bore GI tubing medium grade with all new fittings to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge. |
| 51 | Supply and Fixing 20mm bore gun metal glove or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge. |
| 52 | Supply & fixing Rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position with and including Ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 20mm-210 gram) complete all as specified and as directed by Engineer-in-charge. Note: The rate of 20mm bore ball valves, high pressure of PTMT is included in this iterm and nothing shall be paid extra on this account. |
| 53 | Supply and fixing PVC (SWR) 110 mm bore pipes single socketed , (ISI Marked ) ,fixing with using adhesive, in any length, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.Note: Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule of BoQ. |
| 54 | Supply and fixing PVC (SWR) 110 mm bore pipes single socketed, (ISI Marked ) , in any length with rubber ring joints fixed with wall complete all as specified and directed by Engineer-in-Charge. |
| 55 | Supply and fixing 110 mm bore PVC (SWR) bends (ISI Marked ) in any radius complete all as specified and directed by Engineer-in-Charge. |
| 56 | Supply and fixing 110 mm bore PVC (SWR) junction double, (double T), equal or unequal (ISI Marked ) complete all as specified and as directed by Engineer-in-Charge. |
| 57 | Supply and Fixing 110mm PVC (SWR) vent cowl (ISI Marked )complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply and Fixing Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including makingconnections and fixed in position complete all as specified and as directed by Engr-in-charge. |
| 59 | Supply and fixing 600mm x 450mm size bevelled edge mirror selected quality 5mm thick glass mounted on 6mm thick commercial ply and fixed to wooden plugs with chromium plated brass screws and cup washers, including aluminium frame / beading alround made of aluminium channel, complete all as specified and directed by Engineer-in-Charge. |
| 60 | Material & Labour for Brickwork with sub class ‘B’ burnt clay old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 61 | Material and Labour for Setting coat of 3mm thick in Cement Mortar 1:2 using with trowelled to even and smooth finish complete all as specified and directed Engineer-in-Charge. |
| 62 | Material & Labour for PCC 1:2:4 type B1 using 20 mm graded stone aggregates as in lintel upto 1.5m clear span, cills, steps; seismic and other similar bends, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and thelikeincluding weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engineer-in-Charge. |
| 63 | Material & Labour for Precast cement concrete type 1: 2: 4, type-B1 (using 20 mm graded crushed stone aggregate) as in landings, cover slabs, chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, set and jointed in CM 1:4, complete all as specified and directed by Engineer-in-charge. |
| 64 | Material and labour for PCC (1:3:6) type C-2 using 40 mm graded stone aggregates as in concrete bed for drain pipes of 150 mm bore, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested including form work complete all as specified and as directed by Engineer-in-charge. Note :- (i) Thickness of concrete bed below the barrel of pipe shall be 10 cm. (ii) Width of concrete bed shall be outer diameter of drain pipes (not of sockets / collar) plus 30cm.(iii) Excavation , earth work , returning filling shall be measured and paid seperately under appropriate items of schedule 'A' BoQ. |
| 65 | Material and labour for 150mm bore RCC pipes class NP-2 with socketed ends laid in trench and jointed complete of complete all as specified and directed by Engineer-in-Charge. Note: Excavation , returning filling and removal of earth work shall be measured and paid seperately under appropriate items of Schedule'A' BoQ. |
| 66 | Material and Labour for Construction of soakage well of size 1.20 mtr dia x 3.00mtr effective depth includingearth work such as excavation in any type of soil, returning filling and removal of earth work , foundation in PCC 1:3:6 Type-C-1 using 20mm graded stone aggregates, Honey combing Brick massony built with burnt clay old size bricks ,Top ring made with RCC M-25 Design Mix ,intercepting chamber and screen made with burnt clay old size brick with cement mortar 1:4, RCC M-25 Design Mix cover slab , 150mm bore salt glazed stoneware interconnecting pipes , filled with brick bats compete all as shown in drawing No.CESZ/TD-36/ST/20 SHEET 1/2 AND 2/2 DATED 22-02-2020 |
| 67 | Supply and installation of LLDPE (Linear Low Density Polyethylene )Septic Tank of approved make of 25 user capacity, conforming to relevant specifications, including excavation in all types of soil,providing and laying 100mm thick Plain Cement Concrete 1:4:8 Type D-2, using 40mm graded stone aggregates as in bedding for placing the tank in position, connecting inlet and outlet pipes, filling around the tank with suitable material, and making good the disturbed surfaces complete in all respects as directed by the Engineer-in-Charge. Note: The rate of 100mm thick Plain Cement Concrete 1:4:8 Type D-2, using 40mm graded stone aggregates, excavation and earthwork , filling the suitable material and making good the disturbed surfaces is included in this item and nothing shall be paid extra on this account. |
| 68 | Supply and Fixing 20mm dia (Outer diameter of pipes in mm) 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed by Engineer-in-charge. Note: Earth work and excavation shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ. |
| 69 | Supply and Fixing 20mm dia (Outer diameter ) 3- layer PP-R gate valves (base insert ) as per site requirement complete all as specified and as directed by Engineer-in-charge. |
| 70 | Material and Labour for Cutting of existing PP-R pipe line of 20mm to 75mm bore and inserting with and including NEW PP-R TEE of appropriate size and taping new connection with all accessories complete all as specified and as directed by Engineer-in-charge. Note: The rate of supply and fixing of NEW PP-R TEE of appropriate size is included in this item.Hence bidder shall be quoted his rates accordingly and nothing shall be paid extra on this account. |
| 71 | Material and labour for concealed Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), in new PVC conduit complete with and including 1.5 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked , drawn through with and including new PVC rigid conduit 20mm dia ( heavy duty ) ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with all new fittings and all accessories i.e pipe bend pipe hook, elbow,junction box, pressed steel powder coated sunken box of suitable size (min 60mm deep, suitable length and 1.2mm thick ) and flush fixed with cement mortar 1:4 , 3mm thick bakelite plastic laminated sheet for mounting with frame and top cover for switches 5Amp/6Amp , socket outlet 5Amp/6Amp and fan regulator, for light / fan point controlled by one way switch 5Amp / 6Amp, top cover fixed with brass screws & cup washers, with and including one single core 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) (as in green colour) as continues earth wire connected to earth dolly etc. with and including cutting chases (as required) complete all as specified and as directed by Engineer-in- charge .Notes for serial item nos. 71.00 to 72.00 : (i) switches one way 5 /6 Amp and socket combination 5 /6 Amp shall be measured and paid seperately under respective items of Schedule'A' BoQ.(ii) The rate of cutting chases (as required) is included in this item and nothing shall be paid extra on this account. (iii) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clips as directed by Engineer-in- Charge.The rate of this element is included in this item and nothing shall be paid extra on this account. |
| 72 | Description All as per serial item No. 71.00 here in here -in- before but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 73 | Supply and Fixing switch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified and directed by Engineer-in-Charge. |
| 74 | Supply and Fixing Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal 240 volt complete all as specified and directed by Engineer-in-Charge. |
| 75 | Supply & fixing of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified and directed by Engineer-in-Charge. |
| 76 | Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate for batten fitting complete all as specified and directed by Engineer-in-Charge. |
| 77 | Supply and fixing LED lamp 10 W complete all as specified and directed by Engineer-in-Charge. |
| 78 | Supply and Fixing Decorative ultra slim linear LED 20 Watt 4 Feet Long lighting fixture with extruded aluminium heat sink,environment friendly, Energy efficient , ready to use pack with and including LED Tube complete , with inbuilt electronic driver, PCB, Connector block complete all as per manufactureres instructions with and including connecting up with theree copper flexible cable from ceiling rose to fitting including connectiong up and fixed on with and including two nos.square box of required size complete all as specified and directed by Engineer-in-charge. Notes:(a) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 79 | Supply & Fixing LED Security street light fitting 35 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with electronic gear housed with high pressure die cast aluminum housing LED street light luminaires complete with IP66 protection including all accessories complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 80 | Supply and fixing sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB SPN 4 way 230 V AC with 200 Amp rated copper bus bar, Double Door,08 modules, dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account. |
| 81 | Supply and fixing MCB, SP, AC, 240 volts \\"B\\" series capacity of 06 to 32 Amps, 10kA and making connections complete all as specified and directed by Engineer-in-Charge. |
| 82 | Supply & fixing MCB, SPN (single pole neutral), AC, 240 volts, B series capacity 32 Amps 10kA and making connections complete all as specified and directed by Engineer-in-Charge. |
| 83 | Supply & Fixing Exhaust fan 250 mm sweep , made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m, ISI marked, including necessary work in wall/sheet, including connection cable, nut bolt and other fixing material complete all as specified and directed by Engineer-in-Charge. |
| 84 | Supply and laying or fixing or passing through pipe or binding with fencing/pole etc, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 Sq mm nominal cross section 2 core solid conductor complete all as specified and directed by Engineer-in-Charge. |
| 85 | Material and Labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia medium grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. Please Enable Macros to View BoQ information |