| 1 | Excavation over areas n exc 1.5m deep and getting out of soil in Soft/loose soil complete all as specified and as directed. |
| 2 | Excavation over areas exc 1.5m deep but not exc 3.0m deep and getting out of soil in Soft/Loose soil complete all as specified and as directed. |
| 3 | Excavation in trenches m exc 1.5m wide and n exc 1.5 m in depth, for foundation, etc for shafts, well, cesspits, manholes, pier holes, drains, etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out of soil in Soft/Loose soil complete all as specified and as directed. |
| 4 | M&L for Surface dressing n exc 15 cm deep in soft/Loose soil complete all as specified and as directed. |
| 5 | Removing excavated materials to a distance n.exc. 50 m and depositing where directed at a level n exc 1.50m above the starting point in hard dense soil complete all as specififed and directed |
| 6 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 7 | M&L PCC 1:4:8 (Type D2) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 8 | M&L RCC M-30 (design mix) using 20 mm graded stone aggregate as in foundations, including rafts, footing foundation beams, plinth beam, base for column etc basement slab under ream piles and mass concrete complete all as specified and directed. |
| 9 | M&L RCC M-30 (design mix)using 20 mm graded stone aggregate as in Col, Padestals, Pillars post and struts etc complete all as specified and directed |
| 10 | Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surfaces complete all as specified and directed. |
| 11 | M & L for Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 12 | M&L TMT mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified and directed |
| 13 | All as per item No 12 above but 5mm dia and over up to and including 10mm dia as in stirrups, spacers, binders and the like complete all as specified and directed |
| 14 | M&L for precast cement concrete solid block masonry with solid blocks using PCC 1:3:6, type C1 (using 20mm graded stone aggregate), exc. 10cm in width, set in CM 1:4 all as specified and as directed. |
| 15 | M&L 15mm thick rendering in two layers of 10mm thick backing coat in CM 1:6 and 5mm thick floating coat in CM 1:4 mixed with water proofing compound on all external wall surfaces finished even and smooth without using extra cement. (Note : Water proofing compound shall be measured and paid seperately) |
| 16 | Supply only integral WPC (3% by wt of cement). |
| 17 | M& L for preparation of plastered or unplastered surface and finishing walls with Acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc complete all as specified and as directed by Engineer-in-Charge.(Make Apex Ultima) |
| 18 | M & L for Broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 19 | M&L for providing 75 mm thick, PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base of floors complete all as specified and directed. |
| 20 | M/L 40mm thk PCC 1:2:4 type B-1 using 20 mm graded agg as in flooring finished fair and even without using extra cement complete all as specified and directed. |
| 21 | M&L for Endura Heavy duty parking tiles of size 300x300/400x400 x10 to12mm thick or high dimension (except thickness) of any colour any design durastone weather proof impacr resistant abrasion resistant exterior tiles as in floors etc set and jointed in neat cement slurry over and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.Make : Johnsons/Somany/Orient Bell |
| 22 | Material and labour for providing and fixing stainless steel (Grade 304) railing/chain made of hollow tubes, channels ,plates etc, including welding,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc of required size, on the to of floor or the side of waist slabwith suitable arrangement complete all as specified and directed. |
| 23 | M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over Screed bed or bedding layer of mortar 15 mm thick in cm (1:6) for laying floor finishes all as specified and directed |
| 24 | M&L 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete laid over 10mm thick cement plaster in cement mortar 1:4 complete all as specified & directed. |
| 25 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde- E- 250) quality- A Complete all as specified and as direted. |
| 26 | S&F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. Fe 410 -W (Gde- E- 250) quality- A Complete all as specified and as direted. |
| 27 | Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed. |
| 28 | Dismantling Plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings in roof covering all as specified. |
| 29 | M&L 20mm thick Granite (of any type) work (table rubbed and polished) in Steps, Jambs, Cooking Platform,Dado,Skirting,Floor,wall lining and like in CM (1:4) including pointing in white cement (1:2) using admixture of pigment to match the shade of granite stone including Cutting, Rounded smooth edges and Polishing. |
| 30 | Supply and fix aluminium composite panel sheet of 4 mm thick with 0.5 mm thick aluminium sheet both sides approved colour of Exterior grade including aluminium frame works size(50 x 25 mm) as in wall cladding,ceiling etc fixed with plastic strips (Double sided sticker ) of suitable size of varying thickness of 10mm to 30mm ,applying adhesive over aluminium sections for fixing composite panels and fixed with screws.The joints in panels shall be filled with weather proof sealant,the board shall be stuck with a layer of any colour high intensity reflective grade polymer sticker installed using epoxy adhesive complete all as specified and directed. |
| 31 | S&F 0.50 mm thick prepainted galvalume aluminium zinc coating GI based corrugated steel sheet of colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self taping screws as specified. |
| 32 | S&F 0.50 mm thick prepainted galvalume aluminium zinc coating GI based plain steel sheet of colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self taping screws as specified. |
| 33 | S & F MS Steel work in tubular trusses and tubular posts/ purlins including special shaped washers etc., complete using ERW or induction butt welded tubes conforming to IS :1161-1979 grade st-240 including notching, drilling, fitting, riveting and/or welding or connecting with bed plate, bolt and nuts complete all as specified and as directed |
| 34 | M&L Painting to new steel and iron surfaces of exc. 10cm wide or girth by two coats of synthetic enamel paints over a coat of red oxide primer including preparation complete all as specified and as directed. |
| 35 | S& F Writing letters or figures ( Block, Romen, Italic or Indian ) with stainless steel 304 grade, thickness of steel sheet 2/3mm thick projected type n.exc 25mm thick ( depth of letter 30cm to 40cm heigh, 15cm to 18cm width of each letter, fixed at site over granite stone /walls / plate or any surfaces incl all fixing arrangements adhesive / stainless steel screws , etc complete all as specified and as directed by engineer -in -chargeletter. |
| 36 | M & L for point wiring with PVC insulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including concealed pvc conduit, fixed on wall / ceiling with all accessories, fittings, PVC junction boxes, modular plate etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, etc with necessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressed steel terminal boxes concealed in wall mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws all as specified. One light point controlled by one switch |
| 37 | all as per item no 36 above but One 3 pin switch socket outlet point 5 amps on independent board |
| 38 | All as per item No 36 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and as directed. |
| 39 | Supply and fixing Modular switch 1 way 5 A, 1 module all as specified and directed. |
| 40 | Supply and fixing Modular switch 1 way 15 A, 1 module all as specified and directed. |
| 41 | Supply and fixing modular socket outlet, 2/3 pin combined , 6 Amps, 2 module, 230 volts all as specified and directed. |
| 42 | Supply and fixing modular socket outlet, 2/3 pin combined , 6/16 Amps, 2 module, 230 volts all as specified and directed. |
| 43 | Supply and fix ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and as directed. |
| 44 | Supply and fix metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, double door suitable for mounting MCBs complete all as specified and directed.Note-: Incoming & outgoing connections from the DB shall be provided with proper lugs/ thimbles etc |
| 45 | Supply and fix MCB single pole 240 volts, 6 to 32 amps \\"B\\" series complete all as specified and as directed by Engineer-in-Charge |
| 46 | Supply and fix single pole and netural 240 Volts 32 amps complete all as specified and as directed by Engineer-in-Charge |
| 47 | Supply and fix Recess mounted LED slim 20 w Round type downlighter with die cast aluminium housing prewired upto connection block and connecting with three core PVC copper flexible cable from ceiling rose to connector block, complete all as specified and directed by Engineer-in-Charge. |
| 48 | Supply and fix two way wall washer with aluminium housing prewired upto connection block and connecting with three core PVC copper flexible cable from ceiling rose to connector block, complete all as specified and directed by Engineer-in-Charge. |
| 49 | M & L for sub main wiring complete with two runs of 4 Sqmm FRLS single core PVC insulated single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 4 sqmm FRLS single core multistranded copper conductor as earth continuity conductor,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of casing caping & one run of earth continuity conductor shall be measured as one running metre. |
| 50 | Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric armoured LT UG cable with aluminium conductor of size 16 Sqmm 4 Core in trenches/along the wall/including making all connections, saddles,complete wih aluminium lugs as required at site and as directed. |
| 51 | All as per item No 50.00 above but Cable size of 10 sqmm 2 core. |
| 52 | Excavation in trenches not exceeding 1.50m wide and n.exc 1.5m depth for foundation, laying of UG cables etc or for shafts, wells, cesspits, manholes, pier holes etc not excluding 10 Sqm on plan in hard/dense soil and getting out , complete all as specified and as directed. |
| 53 | Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked all specified and directed. |
| 54 | Material and Labour for cutting existing BT / PCCroad of size 45cm x 60cm for taking out/laying of underground cable/pipe and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 200mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bags and removing debris to a distance not less than 50m complete all as specified and as directed . |
| 55 | S&F in replacement of GI tubing medium grade, 40mm bore ISI marked laid in floor / trenches etc fixing with all GI fittings as required at site including taking out of old pipe complete all as specified and as directed. |
| 56 | S&F Loadline vertical distribution board TPN, 4 ways 415 volts, with 200 amps rated bus bar, with IP 42 protection and double door,complete all as specified and as directed. |
| 57 | S&F MCB TPN, 40 Amps 415 volts, |
| 58 | Supply and fix MCB single pole, 240 volts, 5 to 32 Amps, all as specified and as directed. |
| 59 | Supply and fix MCB SPN 240 volts 32 Amps, all as specified and as directed. |
| 60 | S&F of LED Flood light fitting 70/72 watts,not less than 120Im/watt with pressure die-cost aluminium housing along with prismatic polycarbonate modular secondary lens optics for flood light application with IP66 ingress protection and impact resistance of >110/120 LBW, 10KV SPD inbuilt surge and 10KV external surge protection with front opening driver cover for easy maintenance and soft illumination effect and powder costed complete on fixing on high mast Pole of 12/15 mtrs height all as specified and as directed. Make: Crompton cat No TFS-504-70-57-60D-HL2-GL-NSG or equivalent of other makes as specified in PS |
| 61 | S & F Alluminum conciled profile channel of size 35 x 20 mm with diffused cover end caps and mounting clips for LED Strip lights complete all as specified and directed. |
| 62 | S & F LED cove lighting (Each cove lighting length 5 mtr) provided with high output diffuser including high efficiency electronic driver complete with LED Lamp, prewired upto connection block and connecting with three core pvc copper flexible cable from ceiling rose to connector block, including taking down fitting of any wattage complete all as specified and directed. |
| 63 | Supply and fix Garden light 10 watt IP65 rated inverted pyramid tripod type LED Bollard with soft 360 degree light distribution complete all as specified and as directed. |
| 64 | M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification. Please Enable Macros to View BoQ information |