| 1 | Site clearance ( AOR) |
| 2 | Excavation for road work in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift up to1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3 |
| 3 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Brick masonry work in cement mortar (1:4) in substructure complete excepting pointing and plastering, as per drawing and technical specification Clauses 602, 603, 604, 1202 & 1204 |
| 5 | Supplying, fitting and placing with MS bar reinforcement (Fe 415) in substructrue complete as per drawings and technicalspecification Clauses 1002, 1005, 1010 & 1202 including bending for proper and necessary completion of the work and including supply of steel and wastages, bends, hooks and authorised overlapping shall be measurised as per direction of Engineer-in-charge. |
| 6 | R.C.C. Work with cement, approved coarse sand & 2 cm (3/4\\") guage approved stone ballast in proportions of 1:1.5:3 in R.C.C,COLUMN excluding supply of reinforcement and its bending. But including its fixing and binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, tools & plants etc. required for proper completion of the work Excluding cost of binding wire. si no. 289new item slab |
| 7 | R.C.C. Work with cement, approved coarse sand & 2 cm (3/4\\") guage approved stone ballast in proportions of 1:1.5:3 in Ligther beam excluding supply of reinforcement and its bending. But including its fixing and binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, tools & plants etc. required for proper completion of the work Excluding cost of binding wire. si no. 285 |
| 8 | R.C.C. Work with cement, approved coarse sand & 2 cm (3/4\\") guage approved stone ballast in proportions of 1:1.5:3 in haviear beam excluding supply of reinforcement and its bending. But including its fixing and binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, tools & plants etc. required for proper completion of the work Excluding cost of binding wire. si no. 286 |
| 9 | Brick masonry work in cement mortar (1:4) in substructure complete excepting pointing and plastering, as per drawing and technical specification Clauses 613, 4 & 1204 |
| 10 | Plastering with cement mortar (1:4), 15 mm thick on brick work in substructure as per technical specification Clauses 613.4 & 1204 |
| 11 | Providing wall putty on new surface with approved quality material of Berger/ J.K./Birla or similar make 2 coats. |
| 12 | Finishing wall with water proof cement paint of approved make and quality on new wood with two coat to give an even shade including supply of all materials, labour, Tools & plant etc. requied for proper completion of the work.661+662 |
| 13 | Painting roofs or other iron work in large areas with one coat priming and one coat of approved (above one Sq. Metre) paint (British antesal or equivalent) including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should confirm the ISI no. 103-109. |
| 14 | Providing and fixing 1mm thick M.S. Sheet garge door with frame of 40x40x6mm (1½\\"x12\\"x\\") angle iron 3.15 mm (1/8\\") thick M.S. gusset plate at the junction and comers including supply and fixing of necessary fittings. Lock rail of 15\\" length of oxidised iron and including pintels hooks at the top and applying priming coat of red lead paint on all sides complete. SI NO. 517 |
| 15 | M.S. or iron of heavy sizes such as trusses, built up gates, record racks, roof work, gates etc. includingriviting of welding where necessary . required for proper completion of the work. Si no 503 |
| 16 | supply & fixing r.c.c bench all complete market rate |
| 17 | Supply and fixing Galvanized corrugated iron roofing 24 B.W.G. in position including supply of all materials, labour, Tools & Plants etc. required for proper completion of the work and including wastage. |
| 18 | Supply and fixing 22 B.W.G. Ridges, valley and gutters for iron roofing fixed with J or U bolts 10mm (3/8\\") dia-with G.I. Limpet and bitumen washers complete including supply of all materials, labour, tools & plants etc. required for proper completion of the work and including wastage (Labour only). |
| 19 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 3031 (With Ordinery Earth in Patri work) |
| 20 | Providing and fixing brass stop cock of approved quality : DSR NO.18.16.1 15 mm nominal bore |
| 21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. DSR 17.7.1 |
| 22 | M-150 Brick on edge floor- laid in cement mortar consisting of one part of cement & six part of local sand & pointed with cement mortar 1:2 over and including 8 cm (3\\") base concrete consisting of brick ballast, white lime and surkhi in ratio 100:16:32 including supply of all materials, labour and T&P etc. si no. 614 |
| 23 | Plain/reinforced cement concrete M20 (1:2:4) in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 |
| 24 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density. |
| 25 | Providing and Laying of Interlocking Concrete Block Pavements having thickness 80 mm as per drawings and Technical Specification Clause 1504. Gray Base |
| 26 | Providing and Laying of Interlocking Concrete Block Pavements having thickness 80 mm as per drawings and Technical SpecificationClause 1504. Colour Base ISI MARK |
| 27 | Supplying & Stacking of Selection No.1/doob grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge. 2.35 |
| 28 | Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : 18.17.2 |
| 29 | Supply of fixing of Board |
| 30 | GST Please Enable Macros to View BoQ information |