| 1 | Demolition of reinforced cement concrete as in RCC slabs, beams, etc drains or manhole covers of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 2 | S&F Factory made precast heavy duty drain/ manhole covers including MS frame and including reinforcement as per IS 12592 : 2002 with specified thickness complete all as specified and directed by Engineer-in-Charge of make approved by GE (I) R&D Delhi. |
| 3 | M&L for Precast RCC work (Nominal Mix) (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in slabs supported on walls, man hole cover ,drain covers ,Shelves etc and like complete all as specified and as directed. |
| 4 | Demolition of brick work or stone/ boulder masonary built in cement mortar including all quoins arches, pillars etc but excluding ashler facings dressed stone work and precast concrete articles complete all as specified and as directed by Engineer-in-Charge. |
| 5 | M&L for brick work straight or curved on plan exc 6m mean radius in cement mortar (1:6) with Sub class ‘B’ brick including manhole raising, footpath, etc complete all as specified and as directed by Engineer-in-Charge. |
| 6 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in benching for manholes and haunching around manholes frame for setting, coping, holdfast fixing etc including use of necessary form work and finishing exposed surfaces even and smooth using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 7 | Taking down cement plaster, pointing, on brick/stone/concrete walls, drain surfaces etc including racking out joints, hacking for key, scrubing down with water etc in any position complete all as specified and as directed. |
| 8 | M&L for 15 mm thick Rendering on brick work or concrete surfaces in CM (1:4) mixed with WPC as per manufactures instructions finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply only integral water proofing compound/liquid etc complete all as specified and directed by Engineer-in-Charge. |
| 10 | M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint on newly plastered / untreated wall surfaces complete all as specified and directed. |
| 11 | Earth work in excavation in all kinds of soil by mechanical means / manual means in foundation trenches or drains not exceeding 1.5 m in width, including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil outside Mod Land as directed. |
| 12 | M&L Returning, filling in hard/dense soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed. |
| 13 | Disposal of excavated earth/ building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, outside MOD land for all leads including all lifts involved. |
| 14 | Dismantling of 150mm bore SGSW or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches complete all as specified and directed. |
| 15 | Supply and laying 150mm dia Salt glazed stoneware drain pipes laid in trenches and jointed with cement mortar 1:1 and spun yarn soaked in neat cement slurry complete all as specified and directed. |
| 16 | Providing and laying double wall corrugated DWC HDPE pipe having internal dia 300 mm and thickness ranging from 5 to 8 mm with Pressure Rating/ PN Class as SN-08 conforming to IS 16098- part 2 including laid over prepared bed as per manufacturer instruction complete all as specified and directed by Engr-in-charge. |
| 17 | M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregates) as in bed to drain/ sewage pipe including packing under and haunching against the sides of pipes of up to 300mm internal dia after they are laid and tested complete all as specified and directed by Engineer-in-Charge. |
| 18 | M&L for PVC (SWR) 150mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including demolition and breaking up existing unserviceable PVC pipe and removal of debris complete all as specified and directed by Engineer-in-Charge. |
| 19 | Making connection of drain or sewer line for pipes 150 to 300 mm diameter with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete |
| 20 | S&F in repair 110mm internal dia PVC (SWR) pipes single socketed in any length with rubber led joint fixed to wall with MS clamps or laid in trenches including taking down pipes complete all as specified and directed by Engineer-in-Charge. |
| 21 | S&F PVC (SWR) bends any radius 110 mm dia including taking down complete all as specified and directed by Engineer-in-Charge. |
| 22 | S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and as directed. |
| 23 | S&F 110mm dia PVC (SWR) vent cowl, single, equal or unequal of any length including jointing with soluvent cement as required complete all as specified. |
| 24 | Demolition of plain cement concrete on any description in ground floor and paving n.exc. 30 cm thick below or above ground level complete all as specified & directed. |
| 25 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, complete all as specified and directed. |
| 26 | M&L 100 mm thick cement concrete type D-2,1:4:8 (40mm graded stone aggt) as in sub floors, filling and mass concrete etc complete all as specified. |
| 27 | M & L for machine made Rubber moulded precast concrete interlocking paver block (coloured) of any shape and size with grey cement and pigment conforming to IS 15658-2006 of 60 mm thickness M-35 Grade, complete all as spfd and directed. |
| 28 | M&L 25mm average thickness sand cushioning for laying of interlocking paver blocks complete as specified |
| 29 | Demolition of cement concrete in ground floors and pavings etc not exc 15 cm thick above or below ground level complete all as specified and directed. |
| 30 | Supply and fixing factory made prepolished chequred cement concrete prepolished coloured tiles (300x 300/ 250 x250) x 22 to 25mm thick, set jointed and pointed in neat cement slurry with grey cement mixed with pigment to match the colour of tiles, laid over and incl 20mm thick screed bed in CM 1:4, complete all as specified & directed. |
| 31 | M&L for preparation of newly plastered or unplastered wall surfaces and applying applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 32 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. |
| 33 | M&L glazed ceramic tiles (300x450/ 300x600) x7 to 8 mm thick coloured tiles in vertical surfaces, wall claddings, boundry wall dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match as in dado over 10mm thick cement plaster in CM (1:4) complete all as specified and directed. |
| 34 | M&L for PCC type B1 1:2:4 (using 20mm graded agg) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneeler apexstone, bed plates, including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. Please Enable Macros to View BoQ information |