| 1 | Taking down cement plaster of any description on PCC/stone surface/brick surfaces including raking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed. |
| 2 | Demolition of brickwork/PCC block or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed. |
| 3 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, including removal of entire debris as ordered outside MoD land complete all as directed. |
| 4 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick (above or below ground level) and removal of entire debris as ordered outside MoD land complete all as directed. |
| 5 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to faciliate demolition) including removal of entire debris as ordered outside MoD land complete all as specified and as directed. |
| 6 | Demolition and breaking up drain pipes (Salt glazed stone ware, AC or Reinforced concrete) of 200 mm internal dia set in cement mortar including bedding and haunching complete all as specified and as directed |
| 7 | All same as per serial item No. 6 here-in-above, but 300 mm bore. |
| 8 | All same as per serial item No. 6 here-in-above, but 450 mm bore. |
| 9 | Taking down shutter of any description exc 1 Sqm and not exc 2 Sqm each and refixing in same opening as ordered after other repair works are carried out including easing and adjusting of shutter as required including renewal of unserviceable screws complete all as directed. |
| 10 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 11 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed. |
| 12 | Removing excavated soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed. |
| 13 | M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 14 | M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops, coved fillets and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed. |
| 15 | M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified & as directed. |
| 16 | M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:4) complete all as specified & as directed.Note :- Reinforcement shall be measured and paid for separately under respective item of this Schedule. |
| 17 | M&L for reinforced cement concrete 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formwork and scaffolding complete all as specified and as directed. Note : Reinforcement shall be measured and paid for separately. |
| 18 | Extra for forming fair finished drain or channel upto 60 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred, stopped, ends etc complete all as specified & as directed. |
| 19 | M&L for cutting holes into or through reinforced cement concrete slabs, column, beam, chajja, etc. and making good in cement mortar 1:3 or PCC 1:2:4 type B0 as required for superficial area exceeding 500 sqcm but not exceeding 0.1 Sqm and 30 to 40 cm of depth (of cutting), complete all as specified and as directed. |
| 20 | M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 21 | S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work including welding conforming to Fe.290 (Gde E-165), complete all as specified & as directed. |
| 22 | M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed. |
| 23 | S&F rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, steel ladders etc fixed with angle cleats or other connecting plates etc conforming to Fe-290 (Gde E-165) complete all as specified and as directed. |
| 24 | S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with bolted or welded attachment, including necessary welding etc. conforming to Fe-410-W (Gde E-250) quality `A’ complete all as specified and as directed. |
| 25 | S&F GI Chicken wire mesh cut to size made to shape as ordered including fixed to walls with nails for receiving the plaster complete all as directed. Note : Weight of GI chicken wire mesh shall be 250 to 300 gm/Sqm. |
| 26 | S&F 6 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre board with frame work with screws fixed to false ceiling with and including MS powder coated (white) snap Grid of size 605x605 mm frame work using 24mm x 32mm x 0.7mm main ‘Tee’ runner to be interlocked, 24mm x 32mm x 0.70mm cross ‘Tee’ and 24mm x 32mm x 0.70mm angles fixed to wall for ceiling including necessary supporting hanger with 2 to 3 mm dia GI wire (upto 3.5m long adjustable) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 24x7mm size 60mm long for securing frame work to ceiling suspended @ 1200mm centre to centre both way with PVC rawl plug with & including 6mm thick calcium silicate board as described fixing with clips etc. and ceiling board fixed as per manufacturer’s instructions, with & including painting the ceiling board with two coats of oil emulsion distemper (OBD) of approved shade over a coat of primer on ceiling with & including taking down existing electrical fittings/fixtures and wiring in ceiling and re-fixing the same to its original position or different locations, after completion of false ceiling work including testing on completion as ordered complete all as specified & as directed. |
| 27 | M&L for 75mm thick PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed. Please Enable Macros to View BoQ information |
| 28 | M&L for 75mm thick PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed. Please Enable Macros to View BoQ information |