| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of E/I. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 2 | Earth work in excavation by mecanical means (hydraulic excavater)/manual means in over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) i/c disposal of excavated earth, lead up to 50 m and lift up 1.5, disposed earth to be levelled and neatly dressed in all kind of soil.The contractor has to detect different utilities like sewer line, water supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of E/I. |
| 3 | Extra for every additional lift of 1.5 or part thereof in all kind of soil. |
| 4 | 1.50-3.00 m |
| 5 | 3.00-4.50 m |
| 6 | Centring and shuttering including strutting, propping etc. and removal of form for:- Foundation, footings, bases of columns etc. for mass concrete. |
| 7 | Providing and laying in postion cement concrete of specified grade exculding the cost of centring and shuttering _ All workup to plinth level 1:4:8( 1 cement : 4 Coarse sand zone (ZOne-III) 8 Graded stone aggregate 40 mm Nominal size) |
| 8 | P/L Non-Pressure NP-3 class RCC Spigot Socketed pipe confirming to IS : 458 : 2003 with latest amendment laying in true alignment & position on craddle including with rubber ring (confirming to IS : 5382 with latest amendment testing of laid pipe as per direction of E/I. complete in all respect. |
| 9 | 300 mm dia Sewer pipe |
| 10 | 400 mm dia Sewer pipe |
| 11 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top with 100 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 C.Sand), in side cement plaster 12mm thick with cement mortar 1:3 (1 cement: 3 c.sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement: 3 c.sand: 6 graded stone agg. 40mm n.s.), and making necessary channel in cementconcrete 1:2:4 (1 cement: 2 coarsesand : 4 graded stone agg. 20 mm n.s.) finished with a floating coat of neat cement all complete as per standard design. 0.91 m deep with S.F.R.C cover and frame (heavy duty, HD-20 grade designation 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement: 2 c.sand: 4 graded stone agg. 20mm n.s) including centering shuttering all complete. (Excavation, foot rests and 12m thick cement plaster at the external surface shall be paid for separately). with common burnt clay F.P.S. (non modular) bricks of class designation 100. |
| 12 | Extra depth for circuler type manhole 0.91 m internal dia (at bottom) beyond 0.91 m to 1..67 m. With common burnt clay F.P.S. (non modular) bricks of class designation 100. |
| 13 | Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 Cement : 4 C. Sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 Cement : 3 C. Sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 Cement : 3 C. Sand : 6 graded stone agg. 40 mm n.s.), and making necessary channel in cement concrete 1:2:4 (1 Cement : 2 C. Sand : 4 graded stone agg. 20 mm n.s.) finished with a floating coat of neat cement, all complete as per standard design. 1.68 m deep with SFRC cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS : 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 Cement : 2 C. Sand : 4 graded stone agg. 20mm n.s.) i/c centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately). with common burnt clay F.P.S. (non modular) bricks of class designation 100. |
| 14 | Extra depth for circuler type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m. With common burnt clay F.P.S. (non modular) bricks of class designation 100. |
| 15 | Constructing brick masonry circular type manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 Cement : 3 C. Sand : 6 graded stone agg. 40 mm n.s.), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nomonal size.) finished with a floating coat of neat cement all complete as per standard design.0.91 m deep with S.F.R.C cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS : 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) i/c centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately). With common burnt clay F.P.S. (non modular) bricks of class designation 100. |
| 16 | Extra depth for circuler type manhole 1.52 m internal dia (at bottom) with common burnt clay F.P.S. (non modular) class designation 100 beyond 2.30 m |
| 17 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 c.sand: 4 graded stone agg. 20 mm n.s) cement plastered on both sides with cement mortar 1:3 (1cement: 3 c.sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete |
| 18 | For Pipes 250 to 300 mm dia |
| 19 | For Pipes 350 to 450 mm dia |
| 20 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactrue's permanent identification mark to be visible even after fixing, i/c fixing in manholes with 30 x 20 x 15 cm cement concrete block 1:3:6 (1 Cement : 3 C. Sand : 6 graded stone agg.20 mm n.s.) complete as per design. |
| 21 | 12 mm cement plaster of mix 1:4 (1 Cement : 4 C. Sand). |
| 22 | Neat Cement Punning |
| 23 | Extra for Plastering on circular work not exceeding 6.0 m in radius in one coat |
| 24 | Hiring of Diesel Enginr (including cost of Diesel, lubricant & Operator). |
| 25 | Hiring of Gas Cutting set with oxygen LPG Runin gTime @6Hrs |
| 26 | Hiring Welding Set Runing Time @6 Hrs |
| 27 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m. |
| 28 | Disposal of building rubbish/ malba/ similar unserviceable dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by E/I. beyond 50 m initial lead, for all leads including all lifts involved. |
| 29 | P/L in position Cement Concrete of specified grade excluding the cost of centering and shuttering – all work up to plinth level : 1:11/2:3 (1 Cement : 11/2 C. Sand (zone-cum III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 30 | Providing & fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings this includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of E/I. (external work). |
| 31 | 15 mm nominal outer dia Pipes |
| 32 | 20 mm nominal outer dia Pipes |
| 33 | Excavating trenches of required width for pipes, cables etc. i/c excavation for sockets depth upto 1.5m i/c getting out the excavated materials, returning the soil as required in layers not exceeding 20cm. in depth i/c consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within lead of 50 m. The contractor has to detect different utilities like sewer line, water supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of E/I. .... Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm dia. |
| 34 | P/L following size of Finolex makes PVC pipes 6 Kg/Cm2 with required PVC standard special confirming to IS codes with latest amendment and lowering the same trenches and laying true to alignment and gradient complete I/c the cost of cutting of pipes for making upto length and making joints I/c cost of socket, plstochem PV-85 PVC solvent cement complete. PVC pipe must be confirming to IS : 4985-2000 with latest amendment Make-Finolex Industries Ltd. /Kisan/Supreme industries Ltd. (Rate As per Comparative Statement per Rm.) |
| 35 | a) 110 mm dia with coupler @ 6 Kg/Cm2 Pressure with i/c all PVC standard Specials |
| 36 | b) 160 mm dia with coupler @ 6 Kg/Cm2 Pressure with i/c all PVC standard Specials |
| 37 | S/F of M.S. specials such as Tee, bend, collars, Tapers, Gap pieces, pipes including flanged ends required painting welding as per site requirement 10 mm thick of MS plate etc.complete in all respect as per direction by the E/I |
| 38 | P/F M.S. Clamp. |
| 39 | P/F M.S. Clamp 140 mm dia i/c excavation, reffiling etc. complete as per direction E/I. |
| 40 | P/F M.S. Clamp 160 mm dia i/c excavation, reffiling etc. complete as per direction E/I. |
| 41 | Dismantling & repairing of Drains/Culvert for crossing sewer line up To 300mm dia i/c wall,channels etc and making the same size inculding brick work 1:4 ( 1 cement : 4 C Sand ) brick of class designation 100 with neat cement punuing & cement concrete 1:4:8 (1 cement : 4 Coarse sand :8 garded stone aggregate 40mm nominal size) etc taking 40% old bricks availvable at site (Approx qty 1.17 cum Brick work) i/c dispoasl of unservicable material with in 50 m Lead ( This rate only for plot Please Enable Macros to View BoQ information |