| 1 | Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. |
| 2 | Providing & applying the Tack Coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg/sqm as per MoRT&H/IRC Specifications for Road and Bridge Works. Item to include all materials, labour, machinery/equipment and incidental work required to complete the job. Measurement shall be made for actual surface area of application in square meter as per MORTH Specification and as per direction of the Engineer-in-Charge. |
| 3 | Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 Percent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects. |
| 4 | Providing and laying 40mm thick Bituminous Concrete wearing coat with 100-120 TPH batch type hot mix plant producing an average output of 75 tonne per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 percent of mix and filler, transporting the hot mix to work site, laying with hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRT&H/IRC Specifications for Road and Bridge Works Clause 509 complete in all respect. Item to include all materials, labour, machinery/equipment and incidental work required to complete the job. Measurement shall be made for finished valume of Bituminuous Concrete in cubic meter. |
| 5 | Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.as per MORTH Specification and as per direction of the Engineer-in-Charge. |
| 6 | P/F of retro-reflectorised 3M/Averydennsion / Oraflow with grade XI reflective sheel with colour & design given cautionary, mandatory and informatory sign (90cm equilateral triangle) as per MORTH Specification and as per direction of the Engineer-in-Charge. |
| 7 | P/F of retro-reflectorised 3M/Averydennsion / Oraflow with grade XI reflective sheel with colour & design given cautionary, mandatory and informatory sign (80cm x60cm rectangular) as per MORTH Specification and as per direction of the Engineer-in-Charge. |
| 8 | P/F of retro-reflectorised 3M/Averydennsion / Oraflow with grade XI reflective sheel with colour & design given cautionary, mandatory and informatory sign (60cm circular for spedd limit and prohibited sign boards e.g No U-Turn |
| 9 | P/F of retro-reflectorised 3M/Averydennsion / Oraflow with grade XI reflective sheel with colour & design given cautionary, mandatory and informatory sign (90cm high octagon e.g stop sign board) as per MORTH Specification and as per direction of the Engineer-in-Charge. |
| 10 | Providing and fixing single moulded twin shank reflective road studs size 100x90x20mm made of poly carbonate/ABS moulded body and reflective panels with micro prismatic lens fixed with road surface using epoxy adhesive complete as per clause 804.7.3 of MORT&H 5th revision specifiaction (Company 3M only). |
| 11 | Providing and fixing all dirrectional retro-reflective round delineator short made out of 18 gauge MS pipe of outer dia 47 mm and length 600mm. Delineator powder coated to have 200mm wide high intensity reflective band of colour white and red. Reflective bands protective with welded mesh cage CAT PART No. GPL-11-20 make greens/greenlite including all leads, lifts and carriage of materials as per the direction and entire satisfaction of the Engineer-in-charge. |
| 12 | Providing and eracting a metal beam \\"Thrie\\" beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series Channel in vertical post, 150x75x5 mm, spaced 2 m center to center 2 mtr high with 1.15m below ground level, all steel parts and fitment to be galvanised by hot dip process, all fitting to confirm to IS : 1367 and IS 1364 metal beam rail to be fixed on the vertical post with a space of channel section 150x75x5 mm.546 mm long complete as per clause 810. |
| 13 | Providing and fixing high intesity frade retro reflectiove over head gantry of size 6 mtr. x 1.20 mtr) signage system infromatory boards made of 2 mm thick aluminum sheet conforming to IS 736 to be covered with 3M/Averydennsion / Oraflow with grade XI reflective sheel with colour & design given seprately. The rtro reflective sheet to be fixed agter etching treatment of aluminium sheed is to painted sheet with epoxy paint of standard make (Asian , Berger , narolac), This plate has to be fixed on frame made out of MS angle 35 mm x35mm x5mm of MS tube of 25 mm thick dia and this over head gantry to be foxed with nuts and bolts on tubular structure as per drawing and as per IRC Code of practice or fabrication and assembling of cover head ganrty signage system board , shall be complete in all respect dully painted and reected on RCC 1:2:4 ., The informatory display board to be provided on both side of gantry including all lead,lift and carriage of materials conforming to Clause No 802 of MORT&H specifications . Please Enable Macros to View BoQ information |