| 1 | Surface dressing in soft/loose soil n exc 15 cm deep including rolling and consolidating formation surfaces in cutting ,complete all as specified and directed. |
| 2 | Removing of excavated material soil/stone boulder/grass vegetation etc upto total distance of 25 km out of MoD land and depositing where directed |
| 3 | M&L for broken/crushed with machine of stone/boulder 100 mm thick (compacted thickness) of Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface and including rolling and consolidating formation with exe 8 tonnes to 12 tonnes power roller complete all as specified and directed by EIC. |
| 4 | M&L for cement concrete 75mm thick type D-2, 1:4:8 (40mm graded aggregate) as sub base including necessary form work complete all as specified and directed by EIC. |
| 5 | M&L for 100 mm thick Ready Mixed Cement Concrete M30 (Design mix) (using 20mm graded aggregate) as in hard standing/path, complete all as specified and directed by EIC. |
| 6 | Excaution in trenches n exc 1.5m wide and n exc 1.5m depth, for foundation, etc. or for shafts, wells, cessipts, manholes, etc. n exc 10 Sqm on plan and n ecx 1.5 m in depth and getting out soft/losse soil. |
| 7 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed by EIC. |
| 8 | Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ Thickness of concrete slab is 100mm, complete all as specified and directed by EIC. |
| 9 | Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound, Grade 'A' , complete all as specified and directed by EIC. |
| 10 | M&L for Reinforced concrete pipes, class NP2, laid and jointed complete with collars 150 mm dia, including Plain Cement Concrete 1:3:6 type C-2 (using 40 mm graded aggregate) bed to drain pipes, 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; including necessary shuttering and supports to concrete and for laying beds to falls, complete all as specified and directed by EIC. |
| 11 | Cutting holes 30 cm depth into or through stone walls built in cement mortar or cement lime mortar and walls of cement concrete ,exe 150 sq.cm but n exe 400 sq.cm and making good to existing work complete all as specified and directed by EIC. |
| 12 | S&F Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles, complete all as specified and directed by EIC. |
| 13 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW, 230V / 50Hz, Temperature Range 25 to 70 degree celcius & working pressure 0.8 Bar capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. Make : RACOLD (Model No: Andris Uno 3180607) / BAJAJ (Model No. bajaj shield series crest SKU code : 150977) / Orient (Model No. SWPR25VCG8M2-WG)Note : Contractor will give the warranty - 5 Years of Tank, 2 Years of Heating Element and 2 Years on Other Parts on Geyser supplied. |
| 14 | M & L for point wiring complete with proper colour coding with 1100 Volts grade, 4.0 Sqmm PVC insulated FRLS, unsheathed, wire confirming to IS-694, Part II, ISI marked with multistranded copper conductor drawn in and including PVC concealed conduit of suitable size of wall/ RCC slab/ ceiling/ colunms/ beams etc with all accessories, fittings, PVC junction boxes etc, for mounting modular switches, sockets, fan regulators etc, also including 4.0 Sqmm, PVC insulated, FRLS unsheathed, 1100 Volts multistranded copper conductor green colour as contineous earth wire connected to common earth dolly for one light point/fan/bell point controlled by one way switch, complete all as specified and directed. Note : Rates included for concealed cutting as required at site without any damage and making good in CM 1:4 and matching the surface as required 2 all screws and washer for point wiring shall be Stainless steel. Nothing is extra shall be admisible on this account Make: Benlo/ Polycab/ KEI/ Anchor(Panasonic) |
| 15 | Supply and fixing in repairs Sheet Metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB SP of Capacity upto 20 Amps 240 Volts.Make: Schnieder/Legrand/ C&S/ L&T |
| 16 | Supply & Fix MCB DB SPN 2 way 240 volts Single door, including connecting up with existing cable with new lugs The DB Shall be of Make - Indoasaian/Legrand/ABB/Schnider |
| 17 | Supply and fixing SP 5 to 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.Legrand/L&T/Schnider |
| 18 | S&F Bib taps,15 mm chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed including all accessories fittings in trenches complete all as specified.Make: Jaquar/ Marc/ Kohler |
| 19 | S&F Stop valves, 15 mm Chromium plated concealed type,screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed including all accessories fittings in trenches complete all as specified.Make: Jaquar/ Marc/ Kohler |
| 20 | Supplying and laying of CPVC pipes 15 mm dia SDR 11 & Plain CPVC SDR 11 concealed type including all accessories fittings in trenches complete all as specified.Make: FLOW GUARD/ DUTRON/ FINOLEX/ ASTRAL |
| 21 | M&L for sub main wiring with two single core 2.5 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through PVC concealed conduit with and including PVC insulated 1.5 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly including taking down old unserviceable submain wiring complete all as specified and as directedNote : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.Make of wire : KEI/ BENLO/ Polycab/ Anchor(Panasonic) |
| 22 | S&F concealed type Indicator Lamp Neon switch 1 module one way 20 A capacity operating on 220 V AC, 50 Hz electric supply having Fire Retardant Electric Accessory, Heavy Duty with suitable size modular cover plate & enclosure complete all as specified & directed.Make: Havells/ Anchor/ Schineder |
| 23 | M&L for earthing using GI earthing strip 25 x 4mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 25x4mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed. Please Enable Macros to View BoQ information |