| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. Note : The tiled floor has to be demolished/ dismantled entirely up to the sub base level/ RCC floor level including backing coat irrespective of number of layers of tiles and taking down wall plaster also incuding in wall tiles. |
| 2 | M & L for virified Ceramic tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match |
| 3 | M&L for Virified Ceramic tiles light shade 8-10mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm and not exc 1.00 sqm in floors, skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 4 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. |
| 5 | M&L for Endura tiles/ stone (coloured/ designer) heavy duty of size 300X300mm/400x400mm, 10-12 mm thick, as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15mm thick screed bed in CM 1:6, complete all as specified and dircted. |
| 6 | M&L for laterite tile size 300x150x19 mm thick as in wall, set and jointed with adhesive/ chemical and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, complete all as specified and directed. Note: Tile shade and design approved by Engr -in-Charge/GE. |
| 7 | M&L for 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and directed. |
| 8 | M&L PCC 1:2:4 type B0 (12.5mm graded aggregate) 25mm thick as in floor subbase for receving of floor tiles complete all as specified and directed. |
| 9 | M&L for Glazed ceramic coloured tiles/Wall cladding tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed |
| 10 | M&L for rendering 10mm thick on fair faces of brick work in CM 1:4 as backing coat to receive tiles complete all as specified and directed. |
| 11 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 12 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed. |
| 13 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 14 | Demoitioin of brickwork or stone/ boulder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 15 | M&L for Brickwork with sub- class ‘B’ old size bricks straight or curved on plan exc 6 m mean radius in CM 1:6, complete all as specified and directed. |
| 16 | M&L for Brickwork with subclass ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick walls, built in M 1:4, complete all as specified and directed. |
| 17 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. |
| 18 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 including finished the surface even and smooth with out using extra cement complete all as specified and directed. |
| 19 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 20 | M&L for preparation of new plastered surface of wall and applying two coats of weather coat paint over a coat of primer complete all as specified and directed. |
| 21 | M&L for preparation of new treated wall surface and applying two coats of oil emulsion distemper over a coat of alkali resisant primer complete all as specified and directed. |
| 22 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 23 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 24 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 25 | S&F 2mm thick Fibre glass reinforced translucent/Plain corrugated sheeting with two corrugations side lap fixed with coach screw andwasher in roof, wall etc complete all as specified and directed. |
| 26 | S&F steel work in tubular trusses, rafters, purlins, ledders and other structural work including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.11611979 grade St.-240 complete all as specified and directed. |
| 27 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement etc, complete all as specified and directed. |
| 28 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 29 | M&L for 10mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed. |
| 30 | M&L prepartion of new steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc crome complete all as specified and directed. |
| 31 | Taking down cement plaster including existing roof treatment or fillets on roof surfaces and wall surfaces complete, racking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance exc 250m and not exc 500m all as specified and as directed. |
| 32 | M&L PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in padding concretevfor roof ,Plinth course,copings,string courses,water troughs and the like finished even and smooth including necessary formwork,weathering,slightly rounded or chamfered angles and throating complete all as directed. |
| 33 | M&L for 15 mm thick rendering in cement mortar 1:4 on fair surfaces of brick masonry or concrete surface, finished the surface even and smooth with using extra cement incl using WPC as per manufacturers instructions, complete all as specified and directed. Note : WPC shall be measured and paid separately. |
| 34 | Supply only liquid waterproofing compound (ISI grade only) |
| 35 | M&L for applying two component, cold(brush/roller) applied, UV resistant hybrid Polyurethane waterproof coating on existing roof screed/plaster surface including equipments and supervision charges in following step by (i) Roof substrate must be pressure-washed with water with, a minimum working pressure of 1,400 psi is to be used to remove all dirt, dust, chalking and waste products, complying with standard specification and as directed by the Engineer-in-Charge. (ii) Inspect for cracks over roof screed, roof wall junction, water drain inlets/outlets if any, and clean and moisten them. Crack’s width should be wide up to 5-6 mm with mechanical cutting machine and Apply bond coat of SBR Latex in the ratio of 1:1 (URP 1: Cement 1) followed by groove should be filled with PMM by preparing Polymer modified mortar of CM 1:1 (Silica sand size ≤ 300microns) admixed with SBR Latex at a dosage of 15% of cement.(iii) Providing 300mm x 300 mm Square / rectangle upstand of M20 grade concrete or with PMM around mechanical equipment like HVAC, airconditioning, solar panels. Etc. Apply a coat of two component, cold(brush/roller) applied, UV resistant hybrid Polyurethane waterproof coating allow to cure for 3-4 hours and followed by apply two coats two component, cold(brush/roller) applied, UV resistant hybrid Polyurethane waterproof coating reinforced with 45 Gsm glass fiber mesh or geo textile without dilution in the interval of 4 -6 hrs. Apply Hybrid PU Sealant at around the junction of fabricated stand inserted and wall mounting mechanical fixtures.(iv) Providing Minimum 50mm thick angle fillet with CM of 1:3 admixed with SBR Latex at a dosage of 12-15% of Cement and a bond coat of SBR Latex mixed with Cement at a ratio of 1:1.(v) Premix hybrid Polyurethane waterproof coating components A and B with an electric double paddle mixer stirrer for 2-3 minutes at a slow speed. The concrete surface must be brought into surface saturated dry condition (SSD). Providing and apply first coat of two component, cold(brush/roller) applied, UV resistant hybrid Polyurethane waterproof coating to the existing screed/plaster at a rate of 0.5Kg/sq.mt/coat. Place a 45-GSM glass fiber mesh or 200- 225 GSM raw mesh between the first and second coats while the first coat is still wet. Allow the first coat to dry for 3-4 hours. Apply the second and third coats of two component, cold(brush/roller) applied, UV resistant hybrid Polyurethane waterproof coating with the same application coverage, but in a direction perpendicular to that of the first and second coats. Allow each coat to air cure for a minimum of 3-4 hours after application. Ensure that no void surface is left untreated or uncoated. All coats should be applied in directions perpendicular to each other, ensuring the correct consumption of material, resulting in a total dry film thickness of 1000 microns with system coverage in three undiluted coats at a rate of 1.50 Kg/ sq.mt/coat. Allow the system to air cure for 5-7 days minimum. The material should conform to the specified technical properties:a) Tensile Strength with Fiber ≥9N/mm2 as per ASTM D 2370b) Elongation at break ≥ 200% as per ASTM D 2370c) Crack bridging ability ≥ 3mm as per EN 1062-7-2004(A) d) solid content ≥55% as per ASTM D 1,644-2001e) Abrasion resistance 15mg confirming to ASTM D 4060f) Shore-A 65 as per ASTM D2240 g) Tear Resistance with Fiber 40N/mm as per ASTM D 624.The waterproofing coating shall be applied over the entire horizontal surface and extended onto the vertical surface of the parapet wall, as per the manufacturer methodology as directed by GE/Engineer-in-Charge.Note: All waterproofing work suggested above shall be carried out by the in house application wing of the manufactuer or skilled waterproofing contractor under the guidance of a technical expert from the manufacturer. The technical expert should audit the quality of the waterproofing work and submit the report. The contractor should submit the skilled project waterproofer certificate issued from the manufacturer while receiving the work order. |
| 36 | Dismantling single layer mangalore pattern or similar tiles in roofing incl ridge tiles complete all as specified and directed. |
| 37 | M&L for cement mortar fillets of 40 mm wide and 20 mm thick for laying mangalore pattern tile on roof, in cement mortar 1:4, complete all as specified and directed. |
| 38 | M&L Roof tiles Mangalore pattern interlocking at side joints laid dry complete all as specified and directed. |
| 39 | All as per item No:38 above but except tiles |
| 40 | M&L Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and pointed in cement mortar 1:6. Please Enable Macros to View BoQ information |
| 41 | M&L Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and pointed in cement mortar 1:6. Please Enable Macros to View BoQ information |