| 1 | Supply and install cubical indoor type, weather proof IP-45 AMF Control panel fabricated out of 2.0 mm thick CRCA with RAL 7032 powder coating MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring mounted on angle iron frame made out of 65 mmx65mm angle iron and grouted on PCC incl necessary excavation all as specified and directed. . AMF DG CONTROL PANEL(62.5 KVA) 415 V /440V,50Hz,3 Phase,4 wire AC system floor mounted (a) Power contactor 4Pole,125 A AC-1 Duty Coil Voltage 240VAC,2NO+2NC aux contacts=2nos (b) HRC Fuse fittings with 125A HRC fuse /links=06 Nos (c) Electronic energy meter 5-60A,2x240V AC 3 phase,4wire=01 No (d) Current Transformer CTR 125/5,ACC-CL-1,5a=03 nos (e) Electronic Hooter 12 V DC 96sqmm flush mounting (to be mounted in on accoustic) (f) Aux relay 12V DC with LED ,free wheeling diode,4 C/O contacts at 5A=02 Nos (g) Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=04Nos (h) Aux relay 12V DC with LED ,free wheeling diode,2 C/O contacts at 5A rating DIN rail mounting and plug in base module type=01Nos (j) Aux contactor 240VAC with suitable no NO and NC contacts=01 No (k) LED indicating lamps 240VAC=02 Nos (l) LED indicating lamps 24VDC=02 Nos (m) Push buttons with Elements=07 nos (n) Stay put type push buttons with elements=01 No (o) Selector switch 6pole 2 way,10 A =01 No (p ) MCBSP 6A,6/10KA=08 Nos (q) Glass fuse fitting 2A glass fuse links draw out type=6 nos (r) Glass fuse fitting 2A glass fuse links draw out type( to be fitted in panel)=01 nos (s) Neutral link 10 A (disconnectable type) =06 Nos (t) MCCB 125A,4Pole,25KA=02 nos with spreader links and extended rotary handles (u) AMF controller suitable for 62.5 KVA DG set (v) Multi function meter =02 Nos (w) Control contactor =4 Nos (x) Battery Charger =01 No (y) LED RYB phase indicators = 01Set (z) LED ON & OFF indicators =01 Set (aa) MCB 10A 4 Pole =02 Nos (ab) MCB 6A 2 Pole=01 No |
| 2 | Supply and install cubical outdoor type, , weather proof IP-65 AMF Control panel fabricated out of 3.0 mm thick CRCA with RAL 7032 powder coating MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring . AMF DG CONTROL PANEL(82.5 KVA) 415 V /440V,50Hz,3 Phase,4 wire AC system mounted on angle iron frame and grouted on PCC incl necessary excavation all as specified and directed. (a) Power contactor 4Pole,125 A AC-1 Duty Coil Voltage 240VAC,2NO+2NC aux contacts=2nos (b) HRC Fuse fittings with 125 A HRC fuse /links=06 Nos (c) Electronic energy meter 5-60A,2x240V AC 3 phase,4wire=01 No (d) Current Transformer CTR 125/5,ACC-CL-1,5a=03 nos (e) Electronic Hooter 12 V DC 96sqmm flush mounting (to be mounted in on accoustic) (f) Aux relay 12V DC with LED ,free wheeling diode,4 C/O contacts at 5A=02 Nos(g)Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=04Nos (h) Aux relay 12V DC with LED ,free wheeling diode,2 C/O contacts at 5A rating DIN rail mounting and plug in base module type=01Nos (j) Aux contactor 240VAC with suitable no NO and NC contacts=01 No (k) LED indicating lamps 240VAC=02 Nos (l) LED indicating lamps 24VDC=02 Nos (m) Push buttons with Elements=07 nos (n) Stay put type push buttons with elements=01 No (o) Selector switch 6pole 2 way,10 A =01 No (p) MCBSP 6A,6/10KA=08 Nos (q) Glass fuse fitting 2A glass fuse links draw out type=6 nos (r) Glass fuse fitting 2A glass fuse links draw out type( to be fitted in panel)=01 nos (s) Neutral link 10 A(disconnectable type)=06 Nos (t) MCCB 125A,4Pole,25 KA=02 nos with spreader links and extended rotary handles (u) AMF controller suitable for 82.5 KVA DG set (v) Multi function meter =02 Nos (w) Control contactor =4 Nos (x) Battery Charger =01 No (y) LED RYB phase indicators = 01Set (z) LED ON & OFF indicators =01 Set (aa) MCB 10A 4 Pole =02 Nos (ab) MCB 6A 2 Pole=01 No complete all as specified and as directed. |
| 3 | Supply and install cubical outdoor type, weather proof IP-65 AMF Control panel fabricated out of 3.0 mm thick CRCA with RAL 7032 powder coatingMS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring . AMF DG CONTROL PANEL 200 KVA) 415 V /440V,50Hz,3 Phase,4 wire AC system mounted on angle iron frame and grouted on PCC incl necessary excavation all as specified and directed.(a) Power contactor 4Pole,300 A AC-1 Duty Coil Voltage 240VAC,2NO+2NC aux contacts=2nos (b) HRC Fuse fittings with 300A HRC fuse /links=06 Nos (c) Electronic energy meter 5-60A,2x240V AC 3 phase,4wire=01 No (d) Current Transformer CTR 300/5,ACC-CL-1,5a=03 nos (e) Electronic Hooter 12 V DC 96sqmm flush mounting (to be mounted in on accoustic) (f) Aux relay 12V DC with LED ,free wheeling diode,4 C/O contacts at 5A=02 Nos (g) Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=04Nos (h) Aux relay 12V DC with LED ,free wheeling diode,2 C/O contacts at 5A rating DIN rail mounting and plug in base module type=01Nos (j) Aux contactor 240VAC with suitable no NO and NC contacts=01 No (k) LED indicating lamps 240VAC=02 Nos (l) LED indicating lamps 24VDC=02 Nos (m) Push buttons with Elements=07 nos (n) Stay put type push buttons with elements=01 No (o) Selector switch 6pole 2 way,10 A =01 No (p) MCBSP 6A,6/10KA=08 Nos (q) Glass fuse fitting 2A glass fuse links draw out type=6 nos (r) Glass fuse fitting 2A glass fuse links draw out type( to be fitted in panel)=01 nos (s) Neutral link 10 A(disconnectable type)=06 Nos (t) MCCB 320A,4Pole,36KA=02 nos with spreader links and extended rotary handles (u) AMF controller suitable for 200 KVA DG set (v) Multi function meter =02 Nos (w) Control contactor =4 Nos (x) Battery Charger =01 No (y) LED RYB phase indicators = 01Set (z) LED ON & OFF indicators =01 Set (aa) MCB 10A 4 Pole =02 Nos (ab) MCB 6A 2 Pole=01 No complete all as specified and as directed. |
| 4 | Supply and install cubical outdoor type, weather type, weather proof IP-65 AMF Control panel fabricated out of 3.0 mm thick CRCA MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring . AMF DG CONTROL PANEL 50 KVA) 415 V /440V,50Hz,3 Phase,4 wire AC system mounted on angle iron frame and grouted on PCC incl necessary excavation all as specified and directed.(a) Power contactor 4Pole,125 A AC-1 Duty Coil Voltage 240VAC,2NO+2NC aux contacts=2nos (b) HRC Fuse fittings with 100A HRC fuse /links=06 Nos (c) Electronic energy meter 5-60A,2x240V AC 3 phase,4wire=01 No (d) Current Transformer CTR 100/5,ACC-CL-1,5a=03 nos (e) Electronic Hooter 12 V DC 96sqmm flush mounting (to be mounted in on accoustic) (f) Aux relay 12V DC with LED ,free wheeling diode,4 C/O contacts at 5A=02 Nos (g) Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=04Nos (h) Aux relay 12V DC with LED ,free wheeling diode,2 C/O contacts at 5A rating DIN rail mounting and plug in base module type=01Nos (j) Aux contactor 240VAC with suitable no NO and NC contacts=01 No (k) LED indicating lamps 240VAC=02 Nos (l) LED indicating lamps 24VDC=02 Nos (m)Push buttons with Elements=07 nos (n)Stay put type push buttons with elements=01 No (o) Selector switch 6 pole 2 way,10 A =01 No (p) MCBSP 6A,6/10KA=08 Nos (q) Glass fuse fitting 2A glass fuse links draw out type=6 nos (r) Glass fuse fitting 2A glass fuse links draw out type( to be fitted in panel)=01 nos (s) Neutral link 10 A(disconnectable type)=06 Nos (t) MCCB 100A,4Pole,16KA=02 nos with spreader links and extended rotary handles (u) AMF controller suitable for 50 KVA DG set (v) Multi function meter =02 Nos (w) Control contactor =4 Nos (x) Battery Charger =01 No (y) LED RYB phase indicators = 01Set (z) LED ON & OFF indicators =01 Set (aa) MCB 10A 4 Pole =02 Nos (ab) MCB 6A 2 Pole=01 No complete all as specified and as directed. |
| 5 | Dismantling of old unsv AMF from any location complete all as specified and as directed. |
| 6 | Taking down old unsv cable of any size complete all as specified and as directed. |
| 7 | M& L for XLPE insulated, armoured heavy duty electric cable with copper conductor, 1100 volts grade, cross-sectional area 300 sqmm 3.5Core complete with copper thimbles laid in wall floor and trenches complete all as specified and as directed. |
| 8 | M& L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300sqmm 3.5 core laid in wall floor and trenches complete all as specified and as directed. |
| 9 | M& L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150sqmm 3.5 core laid in wall floor and trenches complete all as specified and as directed. |
| 10 | M& L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm 3.5Core laid in wall floor and trenches complete all as specified and as directed. |
| 11 | M& L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 3.5Core laid in wall floor and trenches complete all as specified and as directed. |
| 12 | M& L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm 4Core laid in wall floor and trenches complete all as specified and as directed. |
| 13 | M& L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm 3.5Core laid in wall floor and trenches complete all as specified and as directed. |
| 14 | M& L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm 3.5Core laid in wall floor and trenches complete all as specified and as directed. |
| 15 | Supply & Installation including testing and commissioning of Feeder Pillar Panel weather proof outdoor type double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7032 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, double door type with locking arrangement for front and back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with Aluminium bus bars of high conductivity aluminium alloy, suitable for 3 phase 4 wire system (R,Y,B,N) rating not less than 400 Amp. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers. The panel shall be provided with digital multifunction meter with accuracy Class 1 with RS 485 Parameters with cast Resign CTs etc and RYB, ON, OFF & Trip LED indicating lamps at incoming.(Continued....) |
| 16 | (Continued from item No.15......)The panel shall be provided with manufacturer's name plate, skull & bones danger notice board, Name plate for Feeder Panel & all incoming and outgoing MCCBs etc. The panel shall be provided 4 Nos 50x50x6 mm thick angle iron supports of not less than each 1.2 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side and suitable extended rotary handles for all Incoming & Outgoing MCCBs complete all as specified and as directed. The overall size of the panel shall not less than 1500mmX600mmX1200mm (LxDxH). The panel shall be provided with 2 Nos of Earthing Terminals one on each side of the Panel with earth strip, suitable size of SS Cable glands for all incoming & outgoing XLPE Cable and including following accessories:- (a) ON Load change over switch four pole with advance neutral 320 Amps Current rating manual chnageover front side handle operated conforming to IS 13947 (Part-3) including RYB Indication lamp both incomimg cables(b) MCCB 4 Pole, 415 Volts, 160 Amp with Thermal Magnetic release, 36 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In, Magnetic Adjustable 5 - 10 x In with both side of spreader links and phase separater etc. – 02 Nos.complete all as specified and as directed. |
| 17 | Supply & Installation including testing and commissioning of Feeder Pillar Panel weather proof outdoor type double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7032 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be+B28 compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, double door type with locking arrangement for front and back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with Aluminium bus bars of high conductivity aluminium alloy, suitable for 3 phase 4 wire system (R,Y,B,N) rating not less than 400 Amp. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers. (Continued....) |
| 18 | (Continued from item No.17......)The panel shall be provided with digital multifunction meter with accuracy Class 1 with RS 485 Parameters with cast Resign CTs etc and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board, Name plate for Feeder Panel & all incoming and outgoing MCCBs etc. The panel shall be provided 4 Nos 50x50x6 mm thick angle iron supports of not less than each 1.2 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side and suitable extended rotary handles for all Incoming & Outgoing MCCBs complete all as specified and as directed. The overall size of the panel shall not less than 1500mmX600mmX1200mm (LxDxH). The panel shall be provided with 2 Nos of Earting Terminals one on each side of the Panel with earth strip, suitable size of SS Cable glands for all incoming & outgoing XLPE Cable and including following accessories:-(a) ON Load change over switch four pole with advance neutral 320 Amps Current rating manual chnageover front side handle operated conforming to IS 13947 (Part-3) including RYB Indication lamp both incoming cables.(b) MCCB 4 Pole, 415 Volts, 250 Amp with Thermal Magnetic release, 36 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In, Magnetic Adjustable 5 - 10 x In with both side of spreader links and phase separater etc. – 03 Nos ( for incoming,mains and out going )complete all as specified and as directed. |
| 19 | Supply and install cubical indoor type, weather proof IP-45 AMF Control panel fabricated out of 2.0 mm thick CRCA with RAL 7032 powder coating MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring . AMF DG CONTROL PANEL(320 KVA) 415 V /440V,50Hz,3 Phase,4 wire AC system floor mounted (a) Power contactor 4Pole,MNX550 AC-1 Duty Coil Voltage 240VAC,2NO+2NC aux contacts=2nos (b) HRC Fuse fittings with 600A HRC fuse /links=06 Nos (c) Electronic energy meter 5-60A,2x240V AC 3 phase,4wire=01 No (d) Current Transformer CTR 300/5,ACC-CL-1,5a=03 nos (e) Electronic Hooter 12 V DC 96sqmm flush mounting (to be mounted in on accoustic) (f) Aux relay 12V DC with LED ,free wheeling diode,4 C/O contacts at 5A=02 Nos (g) Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=04Nos (h) Aux relay 12V DC with LED ,free wheeling diode,2 C/O contacts at 5A rating DIN rail mounting and plug in base module type=01Nos (j) Aux contactor 240VAC with suitable no NO and NC contacts=01 No (k) LED indicating lamps 240VAC=02 Nos(l) LED indicating lamps 24VDC=02 Nos (m) Push buttons with Elements=07 nos (n) Stay put type push buttons with elements=01 No (o) Selector switch 6pole 2 way,10 A =01 No (p) MCBSP 6A,6/10KA=08 Nos (q) Glass fuse fitting 2A glass fuse links draw out type=6 nos (r) Glass fuse fitting 2A glass fuse links draw out type( to be fitted in panel)=01 nos (s) Neutral link 10 A(disconnectable type)=06 Nos(t) MCCB 4Pole 630A,36KA, Ics= 100% Icu=02 Nos with spreader links and extended rotary handles (u) AMF controller suitable for 320 KVA DG set (v) Multi function meter =02 Nos (w) Control contactor =4 Nos (x) Battery Charger =01 No (y) LED RYB phase indicators = 01Set (z) LED ON & OFF indicators =01 Set (aa) MCB 10A 4 Pole =02 Nos (ab) MCB 6A 2 Pole=01 No complete all as specified and as directed. |
| 20 | M& L Earthing complete with galvanised iron earth plate electrode 600 x 600 x 6mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to GI earth lead of 32mm x 6mm , by means of bolts & nuts, to GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part-I of 2009* specified or indicated and testing on completion including excavation / earth work in any type of starta, PCC (1:3:6) type C1 earthing chamber pre cast slab 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 KG/sqm cast iron frame, funnel with wire mesh GI watering pipe of 20 mm bore medium grade and lugs with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade 7.5 meter long etc complete tested on completion complete all as specified and as directed.Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI wire above 7.5m will be measured and paid seperately. |
| 21 | Supply install Testing and commissioning synchronising panel for 3 x 320 KVA DG sets, cubical indoor type, Dust and Vermin proof IP-45 AMF Control panel fabricated out of 2.0 mm thick CRCA MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated RAL 7032/7035 mounted on 65mm angle iron frame incorporating the following items including control wiring (a)Copper Busbar 1200A set of 4(b)MCCB FP 630A,415V 36KA, Ics=100% Icu= 03 Nos(c) Power Contactor 4 Pole 550 A= 03 Nos(d)CT 500/5,10VA=09 Nos(e)Generator Synchronizing Controllers =03Panel Control Switchgear MCBSP 6A=27 NosMCBDP 10A=12nosMCB4Pole 10A=03Contactor 24V DC with 2NO 2NC=21 NosContactor 230V AC =08 NosADD ON Block 2NO/2NC=06NosHooter 24V DC=03 nosLED Indication Lamps 24V DC & 230 V AC =36NosLVM 3 Phase,415V=01Emergency Stop with NO NC Element=03NosAuto /Mannual Selector Switch 3 position with OFF =03 nos(Continued...) |
| 22 | (Continued from item No.21)Terminal 4U selector switch =180 nosEnd Plate 4sqmm /6sqmm terminal=40 nosEnd Clamp 4sqmm /6sqmm terminal=40nosNO NC Element=09nosON Delay Timer=01 noOn load change over 630A,4 Pole ,415V AC mounted on panel =03 NosName plate For Emergency,Controller and other function switches=46nosPriority switch 2Pole and 2 Way=03 NosControl wire 1.5Sqmm,1100 V grade in Red,Yellow,Blue,Black,White and Orange all as specified =1800MShielded Cable 1.0 Sqmm=50RM PVC Cable trays 45mmx60mm=20RM PVC Cable trays 30mmx60mm=15RMDIN Rail=12 NosBattery Charger 20A,24V DC=03 NosMulti function Meter =03 NosDC Ammeter =03 NosDC Volt meter =03 Nos Lugs /Pronted Ferrule for 1.5F/1.5P/2.5F/2.5P as reqd for complete wiring is incl in unit rate complete all as specified and as directed. |
| 23 | M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete in cm 1:6 type C1 using 1:3:6 using 20mm aggregate complete all as specified and as directed. |
| 24 | M&L for rendering 15mm thick cement plaster in CM( 1:6) on block walling surface finished even and smooth without using extra cement complete all as specified |
| 25 | M&L for two coats of synthetic enamel paint on steel surfaces of any description over 10 cm width or grith including preparation of New surfaces and one coat of Red oxide primer complete all as specified and as directed. |
| 26 | Excavation in trenches in hard/dense soil n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out incl dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and as directed. |
| 27 | Excavation in trenches in soft/disintegrated rock n exc 1.5m wide and n.exc 1.5m in depth and getting out complete all as specified and as directed. |
| 28 | Returning, filiing in incl spreading, leveling watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested complete all as specified and as directed. |
| 29 | Removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point, complete all as specified and as directed. |
| 30 | M&L for laying of reinforced concrete pipe, dia of 150 mm 2 nos half round for bottom and top and before laying excaved area shall be levelling complete all as specified and as directed.Note: One half round Top and One half round bottom together will be considered as one running meter.Make as per sample approved by Engr-In-Charge |
| 31 | Material & labour cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and as directed. |
| 32 | Material & labour PCC 1: 3 : 6 type C-1 (using 20 mm graded mechanically crushed stone aggregate) as in stays and coping of poles including necessary form work complete all as specified and as directed. |
| 33 | Surface excavation n exc 30 cm depth and averaging 15 cm depth and getting out in soft /loose soil including clearing away all grass and vegetation saplings , shrubs , bushes , undergrowth roots and removing rubbish upto a distance n exc 50 mtrs outside the periphery of the transformer/ 2 pole /4 pole structure/ feeder pillar area complete all as specified and as directed.(Note:-The contractor will ensure that no vegetation grows during the contract period on the area so excavated) |
| 34 | M&L cleaning and preparing the surfaces to be welded together, holding the members in true position while welding and bevelling of edges, as required, in the case of metal exc 3mm thick but not exceeding 6mm thick running welding in repairs complete all as specified and as directed.. |
| 35 | M&L in replacement of Mild steel chequered plate 10mm thick for ducting edges beaded if directed,holes punched included round headed screws complete all as specified and as directed. |
| 36 | M&L Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') and upper level of duct for supporting cables and duct cover and the size is same as existing including cutting ,welding,fixing,nut bolts and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.( Note : Frames are made as per site requirements ) |
| 37 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size for cable of size 300 to 400 sq mm. ,Indoor/Outdoor type complete all as specified and as directed. |
| 38 | Supply and laying 40 x 32 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 06 to 16 Sqmm 3.5 core complete all as specified and as directed. |
| 39 | Supply and laying 50 x 38 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 25 to 35 sqmm 3.5 core complete all as specified and as directed. |
| 40 | Supply and laying 63 x 50 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 50 Sqmm 3.5 core complete all as specified and as directed. |
| 41 | Supply and laying 77 x 63 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 70 Sqmm 3.5 core complete all as specified and directed by Engr-In-Charge. . |
| 42 | Supply and laying 90 x 75 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 95 Sqmm 3.5 core complete all as specified and as directed. |
| 43 | Supply and laying 110 x 95 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 120 to 150 Sqmm 3.5 core complete all as specified and as directed. |
| 44 | Supply and laying 120 x 103 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 185 to 240 Sqmm 3.5 core complete all as specified and as directed. |
| 45 | Supply and laying 160 x 135 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 300 to 400 Sqmm 3.5 core complete all as specified and as directed. Please Enable Macros to View BoQ information |