| 1 | Taking down existing unservicable treatment of any description including cement plaster/cement concrete of any thickness from roof surface cleaning of roof surfaces and and preparing it for further treatment and removing rubbish from the site up to 50 mtrs complete all as specified and directed. |
| 2 | M&L for screeding 10mm thick in CM 1:4 on fair faces of RCC /stone patti roof surface finished fair and even without using extra cement complete all as specified and directed. |
| 3 | M&L for five layered APP modified polymeric water proofing membrane, 2.10mm thick having centre core not less than 100 micron high molecular high density polythylene film (HMHDPE) protected on both sides with high polymeric asphaltic mix and 20 micron HMHDPE film weight not less than 3.00 Kg/Sqm applied with bonding material using blown type bitumen conforming to IS-702 grade 85/25 @1.20 Kg/Sqm over bitumen primer conforming to IS-3384 @0.40 Kg/Sqm with final coat of bonding bitumen grade 85/25 @1.20 Kg/Sqm over APP membrane with all overlaps (b) A fillet of PCC (1:2:4) type B-0 of 100x100mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of direction. The membrane should not be taken over at any steep turns and hence all corners/timers should be rounded. complete all as per manufacturers instructions complete all as specified and directed. |
| 4 | M & L for PCC 40mm thick (minimum consolideted thickness) type B-0, using 12.5 mmgraded stone aggregate as in padding finished even and smooth wothout using extra cement with existing slope with V shaped grooves 6mm wide and10mm deep @0.40Sqm of each panel on top of padding and filled with mastic bitumen of 1:1 preparation complete all as specified and directed. |
| 5 | M&L for surface preparation for PU by air blower and then wash by water, Dust frees the surface, including removing of old felt / loose plaster / concrete etc. and repair by mortar, After curing then applying 1st coat of liquid Waterproofing membrane Elongation more than 1000% conform (ASTM D41298) (ASTM 96-95), In 2nd coat add 20% of water. Then apply 3rd coat of Rubberized Elastomeric liquid Waterproofing membrane complete all as specified and directed. |
| 6 | Taking down cement or cement lime plaster on stone/brick wall, ceiling incl. raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 7 | M & L for rendering in cement mortar (1:4) 10mm thick as in ceiling surfaces finished fair and even complete all as specified and directed. |
| 8 | M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 9 | Demolition of stone/brick masonry built in cement or cement lime mortar as in portion ordered complete all as specified and directed. |
| 10 | M & L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed. |
| 11 | M & L for walling of random rubble (but except stone), uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed. |
| 12 | M & L for Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, hammer dressing with maximum depression on face from straight edge held against the dressed surface n. exc 20mm complete all as specified and directed. |
| 13 | M & L for rendering 15mm thick in CM 1:4 on stone/brick masonry, external surfaces finished fair & even complete all as specified and directed. |
| 14 | M & L for preparation of newly plaster surfaces of wall & applying two coats of cement base paint complete all as per specified and directed. |
| 15 | Disconnecting existing tanks exc 250 & n exc 500 ltrs, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and refixing in position after cleaning and removing all scale and dirt, etc,from tank complete all as specified and directed. |
| 16 | Disconnecting existing tanks exc 500 & n exc 1000 ltrs, setting aside (or lowering if required) for repairs, etc and hoisting if required reconnecting and refixing in position after cleaning and removing all scale and dirt, etc,from tank complete all as specified and directed. |
| 17 | S&F rotational moulded synthetic (HDPE) water storage tank 500 litre capacity hoisted & fixed in position all as specified in SSR Part-I including dismantling of old existing unsv water tank complete all as specified and directed. |
| 18 | S&F rotational moulded synthetic (HDPE) water storage tank 1000 litre capacity hoisted & fixed in position all as specified in SSR Part-I including dismantling of old unsv water tank complete all as specified and directed. |
| 19 | M&L in repair for 50 mm thick sand stone slabs; set and jointed over joists etc. in CM 1:4 as in base of water tank and M&L 25 mm thick PCC 1:2:4 type B-0 (using 12.5mm stone crushed agg.) finished concrete surfaces even & smooth complete all as specified and directed |
| 20 | Taking up or down steel tubing and connection 15 mm bore and removing the same from site/keeping aside for reuse complete all as specified and directed. |
| 21 | Taking up or down steel tubing and connection 20 mm bore and removing the same from site/keeping aside for reuse complete all as specified and directed. |
| 22 | S & F water tubing 15 mm bore, medium grade, ISI marked galvanized with all fittings and fixed to walls, ceiling or laid in floors complete all as specified and directed. |
| 23 | S & F water tubing 20 mm bore, medium grade, ISI marked galvanized with all fittings and fixed to walls, ceiling or laid in floors complete all as specified and directed. |
| 24 | Refixing 15mm bore old GI tubing to walls, ceiling or laid on floor including necessary cleanig, cutting, screwing and new fittings such as elbow, Tee, union, socket, reducer etc complete all as specified and directed |
| 25 | Refixing 20mm bore old GI tubing to walls, ceiling or laid on floor including necessary cleanig, cutting, screwing and new fittings such as elbow, Tee, union, socket, reducer etc complete all as specified and directed. |
| 26 | S & F in repairs ball valves PTMT high pressure with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe, 20mm bore complete (minimum weight 210 gm ) complete all as specified and directed. |
| 27 | Taking down 20 mm bore gun metal glove valve & Supply and fixing 25mm bore gun metal glove or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 28 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws fixed with L & J hooks and washers, in roofs, walls etc with grade of zink coating 275 including dismantling of old sheet any types complete all as specified and directed. |
| 29 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old sheet any types complete all as specified and directed. |
| 30 | Demolition of cement concrete (unreinforeced) in floors and paving n.exc 15cm thickness (above or below ground level) complete all as specified and directed. |
| 31 | M&L for PCC 1:4:8 type D-2 (using 40 mm thick crushed stone aggregate) as in foundation, mass concrete complete all as specified and directed. |
| 32 | S&F for steel work in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St -240 including dismantling of existing structure any types complete all as specified and directed. |
| 33 | S & F rolled mild steel as in angle setion, fixed indepenntly with or without connecting plates or welding with existing steel or iron surfaces etc and similar work confirming to Gde E-165 (Fe 290) including necessary cutting, welding etc and fixing in position including dismantling of existing structure any types complete all as specified and directed. |
| 34 | M&L for preparation of new steel surface over 10cm width or grith & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer complete all as specified and directed. |
| 35 | M&L for preparation of old steel surface over 10cm width or grith & applying one coat of synthetic enamel paint of 1st quality incl preparation of old surface complete all as specified and directed. |
| 36 | Providing & Fixing false ceiling with Everest Fibre Cement Designer tile Ivory painted (High Pressure Steam Cured) of 4mm thickness (as per IS:14862) of size 595x595 mm and any one of the design (oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30 mm thick sheet, spaced at 1200 mm c/c and cross \\"T\\" of size 15x32 mm made of 0.30 mm sheet, 1200mm long spaced between main \\"T\\" at 600 mm c/c to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size15x32 mm made of 0.30 mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 15x20 mm made of 0.30 mm thick sheet and laying false ceiling tiles in the grid including , required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15mm of all T -sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, including dismantling of old board any types complete all as specified and directed. |
| 37 | S&F 110 mm bore SWR PVC (Rain water pipe/slot pipe) single socket in any length with rubber ring joints fixed to walls including demolition and breaking up old pipe any types complete all as specified and directed |
| 38 | S&F in repair stack clamp out of 30mm by 3mm flat iron and 16 mm dia round iron stays fixed to pipe of bore 110mm complete all as specified and directed |
| 39 | S&F SWR PVC (Rain water pipe) bends/bend shoes suitable for 110mm bore pipe complete all as specified and directed. |
| 40 | Dismantling Single layer of Mangalore Pattern or similar tiles in roofing incl wooden fillet complete all as specified and directed. |
| 41 | M&L for Single layer of Mangalore Pattern or similar tiles in roofing complete all as specified and directed. |
| 42 | M&L for Single layer of Mangalore Pattern(but except tiles) or similar tiles in roofing complete all as specified and directed. |
| 43 | M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles, beded and jointed in cement mortar 1:6 complete all as specified and directed. |
| 44 | Dismantling in unframed fillets, rails, posts, rafter, purlins etc under 40 sqcm in section complete all as specified and directed. |
| 45 | M&L for 2nd class hard wood exc 6 & n exc13 Sqcm plain fillets, square, rectangular in section, clean sawn, secured with nails or brads complete all as specified and directed. |
| 46 | M&L for 2nd class hard wood exc 13 & n exc 25Sqcm plain fillets, square, rectangular in section, clean sawn, secured with nails or brads complete all as specified and directed. Please Enable Macros to View BoQ information |
| 47 | M&L for 2nd class hard wood exc 13 & n exc 25Sqcm plain fillets, square, rectangular in section, clean sawn, secured with nails or brads complete all as specified and directed. Please Enable Macros to View BoQ information |