| 1 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed by Engineer-In-Charge. |
| 2 | M&L for cleaning of drains, under culverts, hume pipes etc. including removing of mud, vegetables, shrubs etc and removing the spoil retrieved during cleaning to a distance beyond 500m and upto total distanceof 1.5Km. Complete all as specified and directed by Engineer-In-Charge. |
| 3 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for. Complete all as specified and directed by Engineer-In-Charge. |
| 4 | M&L for PCC 1:3:6 Type C2 ( 20 mm graded stone aggregate) as in surface channels and bed of drains, finished even and smooth with using extra cement. complete all as specified and directed by Engr-in-charge. |
| 5 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and directed by Engineer-In-Charge. |
| 6 | Ditto all as per item No 05 above, but except bricks etc. (Old bricks retrieved from Ser item No. - 01 shall be reused after cleaning.) Complete all as specified and directed by Engineer-In-Charge. |
| 7 | M&L for Brick work with sub class 'B' bricks using old size bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4. Complete all as specified and directed by Engineer-In-Charge. |
| 8 | Demolition of RCC of any description and in any position not otherwise specifically provided for etc. Complete all as specified and directed by Engineer-In-Charge. |
| 9 | M&L for providing 35 mm thick precast cement concrete louvres and jallies, (measured solid), including all mouldings but excluding frame in cement conc type B0, 1:2:4 and set in CM 1:4. Complete all as specified and directed by Engineer-in-Charge. |
| 10 | M&L for Providing precast cement concrete as in posts to RCC jali , with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match in cement cocncrete type B0, 1:2:4 and set in CM 1:4. Complete all as specified and directed by Engineer-in-Charge. |
| 11 | M&L for precast reinforced cement concrete type B-1, 1:2:4 as in cover slabs over drain/manholes etc. including necessary formwork. Complete all as specified and directed by Engineer-in-Charge. |
| 12 | M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia, complete all as specified and directed by Engineer-in-Charge. |
| 13 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc. Complete all as specified and directed by Engineer-In-Charge. |
| 14 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls, finished fair and even, complete all as specified and directed by Engineer-In-Charge. |
| 15 | M&L for preparation of new plastered surfaces and applying two coats of cement base paint over and including a coat of primer, complete all as specified and directed by Engineer-in-charge. |
| 16 | Demolition of PCC in Ground floors/PCC Path/Plinth Protection and paving not exceeding 15cm thickness (below or above ground level) etc. Complete all as specified and directed by Engineer-In-Charge. |
| 17 | M&L for cement concrete type D2, 1:4:8(40mm graded aggregate) as in foundations, filling, mass concrete/ base to interlock tile/Chequered tile etc. Complete all as specified and directed by Engineer-in-Charge. |
| 18 | M&L for 100mm thick cement concrete type B-2, 1:2:4(using 20mm graded stone aggregate) as in floor laid in alternate bays, finished the surfaces even and smooth without using extra cement. Complete all as specified and directed by Engineer-in-Charge. |
| 19 | M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors/path with grey cement and pigment to match, over and including 20mm thick screed bed in cement mortar 1:6. Complete all as specified and directed by Engineer-In-Charge. |
| 20 | M&L for providing cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in roof kerbs or mud stops, benching etc. rounded or chamfered on edges. Complete all as specified and directed by Engineer-In-Charge. |
| 21 | M&L for sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed by Engineer-in-Charge. |
| 22 | M&L for factory made machine pressed precast concrete interlocking paver block, 60mm thick, any shape and size, confirming to IS-15658-2006, M-35 Grade, with grey cement and pigment,. Complete all as specified and directed by Engineer-in-Charge. |
| 23 | M&L for factory made machine pressed precast concrete interlocking paver block, 80mm thick, any shape and size, confirming to IS-15658-2006, M-40 Grade, with grey cement and pigment,. Complete all as specified and directed by Engineer-in-Charge. |
| 24 | M&L for preparation of old stone/concrete surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint (in alternate colours if required at site), complete all as specified and directed by Engineer-In-Charge. |
| 25 | Dismantling structural steel work including doors, gates etc.). Complete all as specified and directed by Engineer-In-Charge. |
| 26 | M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work onforming to Fe.290.Gde-E-165 . Complete all as specified and directed by Engineer-In-Charge. |
| 27 | Dfitto all as per ser item No. 26 above,but including ornamental and intricate design. Complete all as specified and directed by Engineer-In-Charge. |
| 28 | S&F 1.25mm thick mild steel black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required. Complete all as specified and directed by Engineer-In-Charge. |
| 29 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over and including a coat of red oxide primer. Complete all as specified and directed by Engineer-In-Charge. |
| 30 | M&L for preparation of old steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed by Engineer-In-Charge. |
| 31 | M&L for complete removal of existing treatment and applying two coats of cement base paint, complete all as specified and directed by Engineer-in-charge. |
| 32 | M&L for complete removal of existing treatment of old decorated wall scraping down smoke soot, moulds, moss and efflorescent and trading oil and greasy spots etc (Plastered or unplastered surfaces) etc and applying one coat of acrylic exterior emulsion paint over a coat of wall primer applying by mechanical spray gun complete all as per manufacturer instruction and as specified and directed by Engr-in-Charge. |
| 33 | M&L for PCC 1:2:4 Type B1 ( 20 mm graded stone aggregate) as in bed blocks, coping of interlock tiles etc. Complete all as specified and directed by Engineer-In-Charge. |
| 34 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar, complete all as specified and directed by Engineer-In-Charge. |
| 35 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbingand polishing complete |
| 36 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over and including cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed by Engineer-In-Charge. Please Enable Macros to View BoQ information |