| 1 | M&L for Brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6.00m mean radius built in cement mortar (1:6) including demolition of existing brick work complete all as specified and directed. |
| 2 | M&L for Brick work with sub class 'B' bricks (except bricks) straight or curved on plan exc 6.00m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 3 | M&L for Rendering 15 mm thick in cement mortar (1:4) using fine sand on brick or concrete surface finish even and fair finishing, curing scaffolding including mixing of water proofing compound and taking down of existing cement plaster etc complete all as specified and directed. |
| 4 | M&L for Rendering 15 mm thick in cement mortar (1:6) using fine sand on brick or concrete surface finish even and fair finishing, curing scaffolding including taking down of existing cement plaster etc complete all as specified and directed. |
| 5 | M&L for Complete removal of existing treatment from wall / ceilling by using mechanical sander/grinder complete all as specified and directed. |
| 6 | M&L for Preparation of surfaces of wall / ceiling and applying two coats of weather coat exterior paint over a coat of primer and over a coat of 3mm thick white cement base water proof putty including sanding/grinding complete all as specified and directed (work to be carried upto a height of 7.5m). Make : Asian paints Apex (Ultima)/Berger Paints weather coat Glo/Shalimaar Paints weather PRO+ |
| 7 | M&L for preparation of old surfaces of wall / ceiling and applying two coat weather coat exterior paint complete all as specified and directed (work to be carried upto a height of 7.5m). Make : Asian paints Apex Ultima/Berger Paints weather coat Glo/Shalimaar Paints weatherPRO+ |
| 8 | M&L for Preparation of old plastered surfaces of walls / ceiling by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of oil emulsion distemper on walls/ceiling using mechanical sander/grinder complete all as specified and directed. |
| 9 | M&L for applying 3mm thick damp proof wall care putty, Preparation of puttied wall/ceiling by mechanical sander/grinder and applying two coats of oil bound emulsion distemper over a coat of primer complete all as specified and directed. Make of putty to be approved by GE. |
| 10 | S&F in repair Factory made heavy duty precast RCC Manhole cover confirming to IS 12592 (Part -1 & II) of size1200mm x 450 mm x 75mm of M-30 Grade of concrete and suitably reinforced with 8mm TMT bar spacing at 150mm centre to centre both way strong vibrating compaction by vibratory table including providing MS hook duly black painted, complete all as specified and directed. |
| 11 | S&F in repair Factory made Precast plain / perforated RCC Drain/ manhole cover of size 900x 450 x 50 mm of M-30 grade of concrete reinforced with 8 mm dia TMT bar of Fe- 500 grade at 150 mm c/c spacing both way with strong vibrating compaction by vibratory table including providing MS hook duly black painted complete all as specified and directed. |
| 12 | S&F in repair Factory made Precast plain / perforated RCC Drain/ manhole cover of size 450x 450 x 50 mm of M-30 grade of concrete reinforced with 8 mm dia TMT bar of Fe- 500 grade at 150 mm c/c spacing both way with strong vibrating compaction by vibratory table including providing MS hook duly black painted complete all as specified and directed. |
| 13 | M&L for removing existing water tanks of any description exceeding 250 liters and not exceeding 500 liters capacity, cleaning all Scale dirt etc from tanks and from mouths of circulating pipes including washing with bleaching powder etc reconection and refixing in position with date of cleaning marking with paint complete all as specified and directed |
| 14 | M&L for capsule pattern fully vitrified coloured tiles premium quality of grade BI(a) 9 to 10mm thick (Square or rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in CM 1:6 complete including dismantling of existing floor tiling including cement mortar bedding and removing rubbish off the premises complete all as directed.Note :- Colour as approved by GE. |
| 15 | M&L for Non skid fully vitrified coloured tiles premium quality of grade BI(a) 8 to 9mm thick (Square or rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in CM 1:6 complete including dismantling of existing floor tiling including cement mortar bedding and removing rubbish off the premises complete all as directed. |
| 16 | M&L for Glazed ceramic coloured tiles of size 450x300x7-8mm thick, as in vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in same colour grout to match including rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 for receiving wall tiles and dismantling of existing tile complete all as directed. |
| 17 | S&F 15mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete including taking up or down existing steel tubing pipe complete all as directed. |
| 18 | S&F 20mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete including taking up or down existing steel tubing pipe complete all as directed. |
| 19 | S&F Pre-painted colour galvalume aluminium Zinc coating AZ 150 GI based corrugated steel sheet 0.50 mm thick having tensile strength of 550 Mpa as in roof covering/cladding to wall etc fixed in repairs including dismantling of complete all as directed. |
| 20 | S&F Pre-painted colour galvalume aluminium Zinc coating AZ 150 GI based pre profiled (matching with roof sheet) plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges, gutter fixed in repairs complete all as directed by Engr-in-charge. |
| 21 | Dismantling existing timber scantling in any position complete all as specified and directed. |
| 22 | S&F Rolled structural mild steel work as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.(Fe-410-W(Gde E- 250) quality B). |
| 23 | S&F Mild steel framed work such as grills, grating etc with end of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing and similar work complete all as specified and directed. |
| 24 | M&L for Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including coat of red oxide primer complete all as specified and directed. |
| 25 | M&L for welded steel wire fabric weight n exc 4kg/sqm fixed/welded to wood or steel members complete all as directed |
| 26 | S&F 500 Litres capacity rotational moulded polyethylene water storage tanks, three layered, ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including 15/20mm dia PTMT ball valve complete set and dismantling of existing unserviceable tank and removing from site complete all as specified and directed. |
| 27 | Demolition of cement concrete in ground floor and paving nexc 15cm thickness (below or above ground level) |
| 28 | M&L for PCC 1:4:8 type D-2, (using 40 mm graded stone agg) as in foundation, filling, mass concrete and sub base of floor including demolition of existing old concrete complete all as specified and directed. |
| 29 | M&L for 300x300x25mm heavy duty Chequered cement concrete tile with rubberised mould and of any pattern decided by Engr-in-charge as in floors/pavings laid over 20 mm thick screed bed 1:6 laid and jointed with white cement slurry mixed with pigment to match the shade of tile complete including dismantling of existing tiles with screed bed of any description and in any position complete all as specified and directed. |
| 30 | M&L for Rubberised precast prepolished coloured concrete Interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade complete with & including 25mm thick sand cushioning layer including dismantling of existing damaged flooring etc complete, all as specified and directed.(Make and pattern to be approved before execution of work) |
| 31 | M&L for heavy duty precast prepolished coloured cement concrete cobble stones paver block of size 100x100mm and 80 mm thickness of M-35 grade of fiber reinforced concrete (FRC) with approved colour, design and pattern, thickness & size / shape made by table vibratory method using rubber mould with strong vibratory compaction laid over 100mm thick PCC (1;4;8 type D-2), using 40 mm graded stone agg and 20 mm thick 1:4 Screed bed or bedding layer of mortar including dismantling of existing damaged flooring etc complete, all as specified and directed. |
| 32 | M&L for 75mm thick PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection or similar places, and finishing the surface even and smooth without using extra cement including making joints and necessary formwork and demolition of existing concrete complete all as directed |
| 33 | M&L in repair for 100mm thick PCC type B1 1:2:4 (20mm graded crushed stone aggregate) as in floors and finishing the concrete even and smooth with 3mm thick glass strips using extra cement complete all as specified and directed. |
| 34 | M&L for PCC 1:2:4 Type B-1 (using 20mm graded crushed stone aggregate) as in coping/ benching including weathering, slightly rounded or chamfered angles and throating etc including necessary form work incl demolition of existing cement concrete of any description complete all as specified and directed. |
| 35 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channels and drains including Desludging/ cleaning of open drain of any depth by mechanically means and removal of debrish outside IMA premises complete all as specified and directed. |
| 36 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 37 | Dismantling post or post struts (wood steel or RCC) any section, including taking out embedded portion and making good disturbed ground in natural ground. |
| 38 | Excavation in post holes (similar holes) each nexc 0.5cum getting out and removing surplus soil to distance nexc 50m in hard/dense soil. |
| 39 | M&L for PCC 1:2:4 type B2 (using 20 mm graded aggregade) in foundation for post holes. |
| 40 | S & F mild steel joints angle channel or tee section and fix independently in concrete as fencing post and similar works congorming to Fe 290 Grade E- 165 |
| 41 | S & F mild steel screw bolts purpose made with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed to be fitted with washers and one hexagonal or square nut complete all as directed. |
| 42 | S&F in repair PVC coated MS galvanised chain link fencing of weight not less than 4.0 kg/sqm, PVC coating of 1.5mm and mesh size of 50 x 50mm of any type of standard rail straining bolts etc aperture and dia as decided by Engineer-in-charge.(Weight of fencing shall be ascertained by a board of officer). |
| 43 | M&L MS round bars 10mm dia & over cut to length bent to shape required incl cranking bending spirally for hoping for colm and backing ends and binding with & include MS wire (a headed) not less than 0.9mm dia or securing with clips quality confirming to Fe-410W. |
| 44 | M&L for preparation of cement concrete ground surface by brooming, washing and scrubing with wire brush to remove algae, fungus and moss growth then apply a 02 coats of acrylic waterproof floor paint for outdoor application acrylic waterproof floor paint as per manufacturers instructions to obtain glossy finish etc all as directed by Engr-in-charge. Make: Indigo paints, Asian Paints, Berger paints |
| 45 | M&L for removing/cleaning of debris of any type from IMA premises to outside of Defence land by using tractor trolley and each trip shall clean minimum 3 cum of material complete all as specified and directed.Note :- Each trip shall be of minimum 3 cum debrish. |
| 46 | S&F 4mm thick E-board false ceiling (Classic) including galvanised colour coated snap grid frame for false ceiling, size of grid 605 X 605mm fixed with 1.6 mm dia GI wire suspenders one end tied to roof members and other end connected to main tee of grid framework including taking down existing boards any thickness etc complete all as directed. |
| 47 | M&L for 6mm thick asbestos cement plain building board, fixed to timber and iron frame work with screw including dismantling of existing board complete all as specified and directed. Please Enable Macros to View BoQ information |